Order number | 6GT2601-0AB00 | 6GT2602-0AB00 | 6GT2602-0AB10-0AX0 | |
---|---|---|---|---|
Product type designation | SLG D12 reader | SLG D12S reader | SLG D12S reader | |
Suitability for operation | ISO 15693 Transponder (MDS Dxxx), for connecting to PC systems | ISO 15693 Transponder (MDS Dxxx), for connecting to communication modules | ISO 15693 Transponder (MDS Dxxx), for connecting to communication modules | |
Wireless frequencies |
|
|
| |
Operating frequency Rated value | 13.56 MHz | 13.56 MHz | 13.56 MHz | |
Electrical data |
|
|
| |
Range maximum | 220 mm; Range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964 | 220 mm; Range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964 | 220 mm; Range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964 | |
Protocol with radio transmission | ISO 15693, ISO 18000-3 | ISO 15693, ISO 18000-3 | ISO 15693, ISO 18000-3 | |
Transfer rate with radio transmission maximum | 26.5 kbit/s | 26.5 kbit/s | 26.5 kbit/s | |
Product property multitag-capable | Yes | No | No | |
Transfer rate at the point-to-point connection serial maximum | 38.4 kbit/s | 19.2 kbit/s | 19.2 kbit/s | |
Transmission time for user data |
|
|
| |
| 2.5 ms | 2.5 ms | 2.5 ms | |
| 2.5 ms | 2.5 ms | 2.5 ms | |
Interfaces |
|
|
| |
Standard for interfaces for communication | RS232 | RS422 | RS422 | |
Type of electrical connection | Data: Sub-D, 9-pin, male, voltage: M12, 4-pin, female connector | Data: Sub-D, 9-pin, male, voltage: M12, 4-pin, female connector | M12, 8-pin | |
Mechanical data |
|
|
| |
Material | PA 12 | PA 12 | PA 12 | |
Color | anthracite | anthracite | anthracite | |
Tightening torque of the screw for securing the equipment maximum | 2 N·m | 2 N·m | 2 N·m | |
Mounting distance relating to metal surfaces recommended minimum | 0 mm | 0 mm | 0 mm | |
Supply voltage, current consumption, power loss |
|
|
| |
Supply voltage |
|
|
| |
| 24 V | 24 V | 24 V | |
| 20 ... 30 V | 20 ... 30 V | 20 ... 30 V | |
Consumed current for DC at 24 V |
|
|
| |
| 0.15 A | 0.15 A | 0.15 A | |
| 0.6 A | 0.6 A | 0.6 A | |
Permitted ambient conditions |
|
|
| |
Ambient temperature |
|
|
| |
| -25 ... +55 °C | -25 ... +55 °C | -25 ... +55 °C | |
| -25 ... +70 °C | -25 ... +70 °C | -25 ... +70 °C | |
| -25 ... +70 °C | -25 ... +70 °C | -25 ... +70 °C | |
Protection class IP | IP65 | IP65 | IP65 | |
Shock resistance | EN 60721-3-7 Class 7 M2 | EN 60721-3-7 Class 7 M2 | EN 60721-3-7 Class 7 M2 | |
Shock acceleration | 300 m/s² | 300 m/s² | 300 m/s² | |
Resistance against vibration | 15 m/s² | 15 m/s² | 15 m/s² | |
Design, dimensions and weight |
|
|
| |
Width | 80 mm | 80 mm | 80 mm | |
Height | 40 mm | 40 mm | 40 mm | |
Depth | 160 mm | 160 mm | 160 mm | |
Net weight | 0.23 kg | 0.23 kg | 0.23 kg | |
Mounting type | 2 x M5 screws | 2 x M5 screws | 2 x M5 screws | |
Cable length |
|
|
| |
| 30 m | |||
| 300 m | 300 m | ||
Product properties, functions, components general |
|
|
| |
Display version | - | - | - | |
Standards, specifications, approvals |
|
|
| |
Certificate of suitability | CE, FCC, IC (Canada), UL 60950, safe for cardiac pacemakers | CE, FCC, IC (Canada), UL 60950, safe for cardiac pacemakers | CE, FCC, IC (Canada), UL 60950, safe for cardiac pacemakers | |
MTBF | 23 y | 23 y | 23 y |