RF630R Siemens

Область применения



The stationary reader SIMATIC RF630R is ideal for use in production as well as in logistics scenarios close to the production process. Thanks to the IP65 degree of protection, the high degree of noise immunity and special algorithms, the reader is specially prepared for industrial use in metallic environments.

Mounting and integration are particularly easy using the SIMATIC RF communication modules. The device supports the established EPCglobal Class 1, Gen 2 standard and is offered in three versions: compliant with ETSI for Europe, compliant with FCC for USA/Canada, and compliant with CMIIT for China.

Обзор



SIMATIC RF630R reader

The SIMATIC RF630R reader has been specially designed for the requirements in production. The reader can be used with one or two external antennas (SIMATIC RF620A/640A/642A/660A). The device is integrated into automation systems via the RS422 system interface. Connection to PROFIBUS, PROFINET, and Industrial Ethernet or directly to SIMATIC S7-300 is supported (via communication modules SIMATIC RF170C/180C/182C or ASM 456/475).

Special functions are available for the difficult environmental conditions encountered in production environments, such as reflections and dead zones resulting from metal or superimposed radio fields due to a high reader density. In this manner, process stability is substantially increased by automatic adaptation of the transmit power and intelligent filtering of the reading results.

The SIMATIC RF-DIAG software is available for fast and simple commissioning and diagnostics.

The reader is easily configured by selecting pre-defined profiles and using the well-known FB45 and FB55 function blocks. These are available on the DVD "RFID Systems Software & Documentation" that can be ordered separately. For further information on the configuration, the runtime behavior of SIMATIC RF630R, and on the integration with SIMATIC controllers, please refer to the relevant documentation.

Чертеж



SIMATIC RF630R reader

Технические данные



Order number

6GT2811-4AA00-0AA1

6GT2811-4AA00-1AA1

6GT2811-4AA00-2AA1

Product type designation

RF630R reader ETSI

RF630R FCC reader

RF630R reader CMIIT

Suitability for operation

RF600 transponder, for connecting to communication modules

RF600 transponder, for connecting to communication modules

RF600 transponder, for connecting to communication modules

Wireless frequencies

 

 

 

Operating frequency

865 ... 868 MHz

902 ... 928 MHz

920 ... 925 MHz

Transmit power

65 ... 500 mW

65 ... 500 mW

65 ... 500 mW

Effective radiant power

 

 

 

  • for each external antenna maximum

1 200 mW

1 200 mW

Equivalent isotropically radiated power

 

 

 

  • for each external antenna maximum

2 000 mW

Electrical data

 

 

 

Range maximum

6 m; Observe system manual RF600: Overreaches are possible, range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964

6 m; Observe system manual RF600: Overreaches are possible, range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964

6 m; Observe system manual RF600: Overreaches are possible, range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964

Protocol with radio transmission

EPCglobal Class 1 Gen 2 / ISO 18000-6C

EPCglobal Class 1 Gen 2 / ISO 18000-6C

EPCglobal Class 1 Gen 2 / ISO 18000-6C

Transfer rate with radio transmission maximum

320 kbit/s

320 kbit/s

320 kbit/s

Product property multitag-capable

Yes

Yes

Yes

Transfer rate at the point-to-point connection serial maximum

115.2 kbit/s

115.2 kbit/s

115.2 kbit/s

Transmission time for user data

 

 

 

  • for write access per byte typical

6.3 ms

6.3 ms

6.3 ms

  • for read access per byte typical

1 ms

1 ms

1 ms

Interfaces

 

 

 

Number of external antennas

2

2

2

Standard for interfaces for communication

RS422

RS422

RS422

Type of electrical connection

  • for external antenna(s)

RP-TNC

RP-TNC

RP-TNC

  • for communications interface

M12, 8-pin

M12, 8-pin

M12, 8-pin

Mechanical data

 

 

 

Material

Aluminum, ABS (GF20)

Aluminum, ABS (GF20)

Aluminum, ABS (GF20)

Color

silver/anthracite

silver/anthracite

silver/anthracite

Mounting distance relating to metal surfaces recommended minimum

0 mm

0 mm

0 mm

Supply voltage, current consumption, power loss

 

 

 

Supply voltage

 

 

 

  • for DC Rated value

24 V

24 V

24 V

  • for DC

21.6 ... 30 V

21.6 ... 30 V

21.6 ... 30 V

Consumed current for DC at 24 V

 

 

 

  • typical

0.395 A

0.395 A

0.395 A

  • maximum

0.47 A

0.47 A

0.47 A

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • during operation

-25 ... +55 °C

-25 ... +55 °C

-25 ... +55 °C

  • during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Ambient condition for operation

With operating temperature below -20 °C: Warming-up time at least 10 minutes

With operating temperature below -20 °C: Warming-up time at least 10 minutes

With operating temperature below -20 °C: Warming-up time at least 10 minutes

Protection class IP

IP65

IP65

IP65

Shock resistance

EN 60068-2-27, EN 60068-2-6

EN 60068-2-27, EN 60068-2-6

EN 60068-2-27, EN 60068-2-6

Shock acceleration

500 m/s²

500 m/s²

500 m/s²

Resistance against vibration

200 m/s²

200 m/s²

200 m/s²

Design, dimensions and weight

 

 

 

Width

193 mm

193 mm

193 mm

Height

252 mm

252 mm

252 mm

Depth

52 mm

52 mm

52 mm

Net weight

1.77 kg

1.75 kg

1.75 kg

Mounting type

4 x M6 screws, Vesa 100 with 4 x M4 screws

4 x M6 screws, Vesa 100 with 4 x M4 screws

4 x M6 screws, Vesa 100 with 4 x M4 screws

Cable length

 

 

 

  • of antenna cable minimum

1 m

1 m

1 m

  • of antenna cable maximum

40 m

40 m

40 m

  • for RS 422 interface maximum

100 m

100 m

100 m

Product properties, functions, components general

 

 

 

Display version

3-color LED

3-color LED

3-color LED

Product property silicon-free

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Certificate of suitability

Wireless according to R&TTE guideline, CE, IEC 60950

Wireless according to FCC, IC (Canada), cULus

RaWireless according to CMIIT

MTBF

19 y

19 y

19 y

Accessories

 

 

 

accessories

up to 2 external antennas

up to 2 external antennas

up to 2 external antennas


Дальнейшая информация



All current approvals can be found on the Internet at:

http://www.siemens.com/rfid-approvals