RF650R Siemens

Область применения



The stationary SIMATIC RF650R reader with its integral antenna is ideal for typical gate applications in logistics, distribution, supply chain management and asset management. The SIMATIC RF650R supports the established EPCglobal Class 1, Gen 2 standard, among others, and is offered in three versions: compliant with ETSI for Europe, FCC for USA/Canada, and CMIIT for China.

Обзор



The high-performance SIMATIC RF650R reader has four antenna connections that can be configured as required for individual read stations, or as gates. The high radiated power of up to 2 W ERP / 4 W EIRP (dependent on antenna and cable) permits long ranges of up to 8 m in portal applications.

The integrated processing logic of the reader enables numerous functions of the higher-level software layers to be executed in the device itself. If necessary, the digital outputs for signaling functions are automatically controlled. The advantage of the SIMATIC RF650R is that its intelligence considerably reduces the cost for additional software modules (RFID middleware).

Configuration, commissioning and diagnosis is performed via an easy-to-use Web interface that can be operated with a standard Internet browser.

The reader supports commissioning, such as the orientation of the antenna(s), or the determining of the necessary radiant power by means of corresponding tools. A variety of diagnostic displays, such as the live radio signal diagram or the diagnostic logbook considerably simplifies and speeds up troubleshooting.

Data communication in the SIMATIC RF650R is executed by means of an XML protocol via TCP/IP. The digital inputs and outputs (DI/DO) are used for simple process interfacing (sensors, actuators).

All antennas of the RF600 series are supported.

Чертеж



SIMATIC RF650R reader

Технические данные



Order number

6GT2811-6AB20-2AA0

6GT2811-6AB20-1AA0

6GT2811-6AB20-0AA0

Product type designation

Reader RF650R CMIIT

Reader RF650R FCC

Reader RF650R ETSI

Suitability for operation

RF600 Transponder, for connecting via Ethernet

RF600 Transponder, for connecting via Ethernet

RF600 Transponder, for connecting via Ethernet

Wireless frequencies

 

 

 

Operating frequency

920 ... 925 MHz

902 ... 928 MHz

865 ... 868 MHz

Transmit power

3 ... 1 000 mW

3 ... 1 000 mW

3 ... 1 000 mW

Effective radiant power

 

 

 

  • for each external antenna maximum

2 000 mW

2 000 mW

Equivalent isotropically radiated power

 

 

 

  • for each external antenna maximum

4 000 mW

Electrical data

 

 

 

Range maximum

8 m; Observe system manual RF600: Overreaches are possible, range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964

8 m; Observe system manual RF600: Overreaches are possible, range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964

8 m; Observe system manual RF600: Overreaches are possible, range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964

Protocol with radio transmission

EPCglobal Class 1 Gen 2 / ISO 18000-6C

EPCglobal Class 1 Gen 2 / ISO 18000-6C

EPCglobal Class 1 Gen 2 / ISO 18000-6C

Transfer rate with radio transmission maximum

300 kbit/s

300 kbit/s

300 kbit/s

Product property multitag-capable

Yes

Yes

Yes

Transmission time for user data

 

 

 

  • for write access per byte typical

2 ms

2 ms

2 ms

  • for read access per byte typical

0.15 ms

0.15 ms

0.15 ms

Interfaces

 

 

 

Number of external antennas

4

4

4

Standard for interfaces for communication

Ethernet

Ethernet

Ethernet

Type of electrical connection

  • for external antenna(s)

RP-TNC

RP-TNC

RP-TNC

  • for supply voltage

M12, 8-pin, connector

M12, 8-pin, connector

M12, 8-pin, connector

  • for communications interface

RJ45

RJ45

RJ45

  • at the digital inputs/outputs

M12, 12-pin, female connector

M12, 12-pin, female connector

M12, 12-pin, female connector

Number of digital inputs

4

4

4

Number of digital outputs

4

4

4

Mechanical data

 

 

 

Material

Aluminum, Pocan

Aluminum, Pocan

Aluminum, Pocan

Color

silver, TI-Grey

silver, TI-Grey

silver, TI-Grey

Mounting distance relating to metal surfaces recommended minimum

0 mm

0 mm

0 mm

Supply voltage, current consumption, power loss

 

 

 

Supply voltage

 

 

 

  • for DC Rated value

24 V

24 V

24 V

  • for DC

21.6 ... 30 V

21.6 ... 30 V

21.6 ... 30 V

Consumed current for DC at 24 V

 

 

 

  • typical

0.37 A

0.37 A

0.37 A

  • maximum

2 A

2 A

2 A

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • during operation

-25 ... +55 °C

-25 ... +55 °C

-25 ... +55 °C

  • during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Ambient condition for operation

With operating temperature below -20 °C: Warming-up time at least 10 minutes

With operating temperature below -20 °C: Warming-up time at least 10 minutes

With operating temperature below -20 °C: Warming-up time at least 10 minutes

Protection class IP

IP30

IP30

IP30

Shock resistance

EN 60068-2-27, EN 60068-2-6

EN 60068-2-27, EN 60068-2-6

EN 60068-2-27, EN 60068-2-6

Shock acceleration

500 m/s²

500 m/s²

500 m/s²

Resistance against vibration

200 m/s²

200 m/s²

200 m/s²

Design, dimensions and weight

 

 

 

Width

258 mm

258 mm

258 mm

Height

258 mm

258 mm

258 mm

Depth

80 mm

80 mm

80 mm

Net weight

2.4 kg

2.4 kg

2.4 kg

Mounting type

Vesa 100 with 4 x M4 screws, top-hat rail 35 mm, profile rail S7-300, S7-1200 or S7-1500

Vesa 100 with 4 x M4 screws, top-hat rail 35 mm, profile rail S7-300, S7-1200 or S7-1500

Vesa 100 with 4 x M4 screws, top-hat rail 35 mm, profile rail S7-300, S7-1200 or S7-1500

Cable length

 

 

 

  • of antenna cable minimum

1 m

1 m

1 m

  • of antenna cable maximum

40 m

40 m

40 m

Product properties, functions, components general

 

 

 

Display version

LED row with 6 LEDs

LED row with 6 LEDs

LED row with 6 LEDs

Product property silicon-free

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Certificate of suitability

RaWireless according to CMIIT

Wireless according to FCC, IC (Canada), cULus

Wireless according to R&TTE guideline, CE, IEC 60950

MTBF

31 y

31 y

31 y

Accessories

 

 

 

accessories

up to 4 external antennas, set for mounting on top-hat rail or profile rail

up to 4 external antennas, set for mounting on top-hat rail or profile rail

up to 4 external antennas, set for mounting on top-hat rail or profile rail