SINAMICS G180 cabinet systems Siemens

Обзор
SINAMICS G180 cabinet systems comprise SINAMICS G180 compact units which are combined with Rittal TS8 cabinets and customer-specific control accessories to create individual cabinet systems.
Global use
SINAMICS G180 converter cabinet systems are manufactured in compliance with relevant international standards and regulations, and are therefore suitable for global use (see technical data).
SINAMICS G180 – cabinet system with four compact units
Дизайн
- Modular principle permits the design of cost-optimized, customized systems
- A complete installation can be quickly and easily assembled through the integration of various industry-specific control packages
- Use of CAE/CAM systems increases flexibility and shortens delivery times
- Capable of integration in any control concept thanks to customized design
- Capable of adaptation to numerous bus systems
- Overall concept is devised to minimize space requirements
- Rittal TS8 cabinet system ensures acceptance anywhere in the world
- Optimum use of space thanks to different cabinet sizes
- Easy to adapt to an extensive range of climatic conditions
- Quick access to all components from front of cabinet eases maintenance
- Additional fans are not generally required
- Cable entry from below incl. cable clamping bar, shielding bus and grounding bar
Number of compact units in cabinet system (depending on width)
Compact units | Cabinet system width | |||
---|---|---|---|---|
600 mm | 800 mm | 1000 mm | 1200 mm | |
165 mm wide 2.2 … 11 kW (400 V) 2.2 … 15 kW (500 V) | 3 | 4 | 5 | 6 |
225 mm wide 15 … 30 kW (400 V) 22 … 37 kW (500 V) 7.5 … 22 kW (690 V) | 2 | 3 | 4 | 4 |
350 mm wide 37 … 110 kW (400 V) 45 … 132 kW (500 V) 30 … 132 kW (690 V) | 1 | 2 | 2 | 3 |
500 mm wide 132 … 160 kW (400 V) 160 … 200 kW (500 V) 160 … 200 kW (690 V) | 1 | 1 | 1 | 2 |
This overview applies to cabinet systems without an additional control system (except for option S31). We would be happy to assist with optimization of the cabinet system width.
Чертеж
Standard cabinet size for cabinet systems (option H81)
Dimensional drawing applies to standard cabinet systems (option H81) with converter without options. The cabinet dimensions might change if options are selected.
Опции
The following tables provide an overview of the options and their availability for SINAMICS G180 compact units in control cabinets (cabinet systems) with a supply voltage of 400 V, 500 V or 690 V. (For details, see catalog chapter 4 "Option descriptions".)
|
| SINAMICS G180 cabinet systems (compact units installed in a control cabinet) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| 400 V TN/TT system | 500 V IT system | ||||||||||
|
| Version – see selection and ordering data | |||||||||||
Option text | Additional ordering data -Z with order code and, if necessary, with plain text specification | A | B | C | D | E | F | G | H | I | J | K | L |
Converter cabinet width | |||||||||||||
406 mm | H80 | ✓ | ✓ | ✓ | – | – | – | ✓ | ✓ | ✓ | – | – | – |
606 mm | H81 | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ |
806 mm | H82 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1006 mm | H83 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1206 mm | H84 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1406 mm | H85 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1606 mm | H86 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Additional cabinet | |||||||||||||
400 mm | H90 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
600 mm | H91 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
800 mm | H92 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1000 mm | H93 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1200 mm | H94 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltages | |||||||||||||
Line voltage 380 V, 50 Hz | V70 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 400 V, 50 Hz | V71 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 415 V, 50 Hz | V72 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 500 V, 50 Hz | V73 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 660 V, 50 Hz | V74 | – | – | – | – | – | – | – | – | – | – | – | – |
Line voltage 690 V, 50 Hz | V75 | – | – | – | – | – | – | – | – | – | – | – | – |
Line voltage 440 V, 60 Hz | V76 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 460 V, 60 Hz | V77 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 480 V, 60 Hz | V78 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 600 V, 60 Hz | V79 | – | – | – | – | – | – | – | – | – | – | – | – |
Line voltage 660 V, 60 Hz | V80 | – | – | – | – | – | – | – | – | – | – | – | – |
Special line voltage; please specify voltage | Y70 • and identification code | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) |
External auxiliary power supply | |||||||||||||
Connection for 230 V 1 AC 50 Hz auxiliary voltage provided by customer | C36 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 400 V 3 AC 50 Hz auxiliary voltage provided by customer | C38 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 500 V 3 AC 50 Hz auxiliary voltage provided by customer | C43 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 690 V 3 AC 50 Hz auxiliary voltage provided by customer | C48 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for other 3 AC voltage provided by customer; please specify voltage | Y36 • and identification code | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
External control voltage supply | |||||||||||||
Connection for 230 V 1 AC 50 Hz control voltage provided by customer, without UPS backup | C56 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 230 V 1 AC 50 Hz control voltage provided by customer, with UPS backup | C57 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for different 1 AC control voltage (47 to 63 Hz) provided by customer; please specify voltage | Y55 • and identification code | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
RFI suppression filter | |||||||||||||
RFI suppression filter, category C2 or C3 (class A) | L00 | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | – | – | – | – | – | – |
RFI suppression filter, category C1 (class B) | L02 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | – | – | – | – | – | – |
Line Harmonics Filter | |||||||||||||
Line Harmonics Filter for 50 Hz line frequency up to 500 V | L03 | H813) | H813) | H823) | H823) | H813) | H813) | H813) | H813) | H823) | H823) | H813) | H813) |
Line Harmonics Filter for 60 Hz line frequency up to 480 V | L04 | H813) | H813) | H823) | H823) | H813) | H813) | H813) | H813) | H823) | H823) | H813) | H813) |
Output filter | |||||||||||||
Strengthened dv/dt output filter for max. 250/300 m (type-dependent). Design for longer motor cables available on request | L10 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ |
Sine-wave filter integrated in control cabinet, suitable for motor frequencies of ≤ 75 Hz, voltage drop of approximately 5 % of line voltage | L17 | ✓ | ✓ | ✓ | ✓ | ✓ | H813) | ✓ | ✓ | ✓ | ✓ | ✓ | H813) |
Standard accessories packages | |||||||||||||
Peripheral board 4 (G05) instead of peripheral board 2 (G03) (only in conjunction with package S01, S02, S03, S04, S08, S09, S11, S12) | G08 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package S01 with main switch, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch | S01 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package S02 with circuit breaker, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch | S02 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package with main switch, line contactor, board G03, local/remote switch | S03 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package with circuit breaker, line contactor, board G03, local/remote switch | S04 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package with main switch, line contactor, Calomat, RCU box connection | S06 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Bypass for smooth line synchronization (soft start function) incl. line-side main switch and contactors at the converter output and in bypass | S08 | ✓ | ✓ | ✓ | ✓ | H823) | H833) | ✓ | ✓ | ✓ | ✓ | H823) | H833) |
Bypass for smooth line synchronization (soft start function) incl. line-side circuit breaker and contactors at the converter output and in bypass | S09 | ✓ | ✓ | ✓ | ✓ | H823) | H833) | ✓ | ✓ | ✓ | ✓ | H823) | H833) |
Accessories package S11 with line-side main switch, board G03, local/remote switch | S11 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package S12 with line-side circuit breaker, board G03, local/remote switch | S12 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Bypass with line-side main switch, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch | S21 | ✓ | ✓ | ✓ | ✓ | H823) | H833) | ✓ | ✓ | ✓ | ✓ | H823) | H833) |
Bypass with line-side circuit breaker, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch | S22 | ✓ | ✓ | ✓ | ✓ | H823) | H833) | ✓ | ✓ | ✓ | ✓ | H823) | H833) |
Bypass with line-side main switch, contactors at converter output and in bypass, EMERGENCY OFF safety relay, switchover between manual and automatic, local/remote switch | S23 | ✓ | ✓ | ✓ | ✓ | H823) | H833) | ✓ | ✓ | ✓ | ✓ | H823) | H833) |
Bypass with line-side circuit breaker, contactors at converter output and in bypass, EMERGENCY OFF safety relay, switchover between manual and automatic, local/remote switch | S24 | ✓ | ✓ | ✓ | ✓ | H823) | H833) | ✓ | ✓ | ✓ | ✓ | H823) | H833) |
NAMUR a Запрос коммерческого предложения× Сообщение отправлено× В ближайшее время сообщение будет обработано. Письмо с номером обращения отправлено на Ваш почтовый ящик. Спасибо за то, что выбрали Первый ZIP! Что-то пошло не так...× К сожалению, наша система расценила Ваше сообщение как спам. Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте. Приносим извинения за возможные неудобства. |