SINAMICS G180 cabinet units - air-cooled and liquid-cooled Siemens

Обзор
Example of SINAMICS G180 air-cooled converter cabinet unit
With its SINAMICS G180 cabinet units, Siemens is offering a drive system on which all line-side and motor-side components are integrated extremely compactly into a specially designed cabinet enclosure. This approach minimizes the effort and expense required to configure and install them.
SINAMICS G180 cabinet units are available in air-cooled and liquid-cooled versions.
SINAMICS G180 converter cabinet units are available for the following voltages and power ratings:
Rated line voltage | Power |
---|---|
400 V 3 AC | 200 ... 630 kW1) |
500 V 3 AC | 250 ... 800 kW1) |
690 V 3 AC | 250 ... 6600 kW |
1) Higher outputs available on request.
Global use
SINAMICS G180 converter cabinet units are manufactured in compliance with relevant international standards and regulations, and are therefore suitable for global use (see technical data).
Air-cooled converter cabinet units
Air-cooled converter cabinet units are equipped with an ingeniously designed, highly efficient air guidance system which is quiet in operation.
Liquid-cooled converter cabinet units
These specially designed liquid-cooled versions of the SINAMICS G180 converter cabinet unit are extremely quiet in operation. Closed control cabinets in degree of protection IP54 or higher make these liquid-cooled converters suitable for applications in harsh environmental conditions.
The advantages of the liquid-cooled version as compared to the air-cooled version are as follows:
- Very low thermal loading of switch rooms
- Can be used almost anywhere, even in atmospheres harmful to machines, thanks to the IP55 degree of protection (IP54 with display in cabinet door)
- Reliable even at higher ambient temperatures up to 55° C thanks to optimal cooling effect
- Reduced noise emission through elimination of the cooling ventilation
- Improved efficiency
- The water-conveying parts of the cooling system are made of stainless steel (V2A), making it resistant to almost any water quality
Опции
The following tables provide an overview of the options and their availability for SINAMICS G180 cabinet units with a supply voltage of 400 V, 500 V or 690 V. (For details, see catalog chapter 4 "Option descriptions".)
|
| Air-cooled and liquid-cooled versions of SINAMICS G180 cabinet units | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| 400 V | 500 V | 690 V | ||||||||||||
Pulse number |
| 6 | 12 | 6 | 12 | 6 | 12 | |||||||||
Version – see selection and ordering data | ||||||||||||||||
Option text | Additional ordering data -Z with order code and, if necessary, with plain text specification | A | B | C | D | E | F | G | H | I | J | K | L | M | N | O |
Line voltages | ||||||||||||||||
Line voltage 380 V, 50 Hz | V70 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | – | – | – | – | – | – | – |
Line voltage 400 V, 50 Hz | V71 | ❑ | ❑ | ❑ | ❑ | ❑ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 415 V, 50 Hz | V72 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 500 V, 50 Hz | V73 | – | – | – | – | – | ❑ | ❑ | ❑ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 660 V, 50 Hz | V74 | – | – | – | – | – | – | – | – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 690 V, 50 Hz | V75 | – | – | – | – | – | – | – | – | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ |
Line voltage 440 V, 60 Hz | V76 | – | – | – | – | – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 460 V, 60 Hz | V77 | – | – | – | – | – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 480 V, 60 Hz | V78 | – | – | – | – | – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 600 V, 60 Hz | V79 | – | – | – | – | – | – | – | – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Line voltage 660 V, 60 Hz | V80 | – | – | – | – | – | – | – | – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Special line voltage; please specify voltage | Y70 • and identification code | ✓1) | ✓1) | ✓1) | ✓1) | ✓1) | ✓2) | ✓2) | ✓2) | ✓3) | ✓3) | ✓3) | ✓3) | ✓3) | ✓3) | ✓3) |
Additional cabinet | ||||||||||||||||
400 mm | H90 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
600 mm | H91 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
800 mm | H92 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1000 mm | H93 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
1200 mm | H94 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
External auxiliary power supply | ||||||||||||||||
Connection for 230 V 1 AC 50 Hz auxiliary voltage provided by customer | C36 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 400 V 3 AC 50 Hz auxiliary voltage provided by customer | C38 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 500 V 3 AC 50 Hz auxiliary voltage provided by customer | C43 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 690 V 3 AC 50 Hz auxiliary voltage provided by customer | C48 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for other 3 AC voltage provided by customer; please specify voltage | Y36 • and identification code | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
External control voltage supply | ||||||||||||||||
Connection for 230 V 1 AC 50 Hz control voltage provided by customer, without UPS backup | C56 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for 230 V 1 AC 50 Hz control voltage provided by customer, with UPS backup | C57 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Connection for different 1 AC control voltage (47 to 63 Hz) provided by customer; please specify voltage | Y55 • and identification code | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Other option | ||||||||||||||||
Board for mains supply backup | E85 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
RFI suppression filter | ||||||||||||||||
RFI suppression filter, category C2 or C3 (class A) | L00 | ❑ | ❑ | ❑ | ❑ | – | ✓ | ✓ | – | ❑ | ❑ | ❑ | ✓ | ✓ | ✓ | – |
Line Harmonics Filter | ||||||||||||||||
Line Harmonics Filter for 50 Hz line frequency | L03 | H926) | H926) | H936) | ✓5) | – | H936) | ✓5) | – | H926) | H936) | ✓5) | H926) | H936) | ✓5) | – |
Line Harmonics Filter for 60 Hz line frequency | L04 | H926) | H926) | H936) | ✓5) | – | H936) | ✓5) | – | H926) | H936) | ✓5) | H926) | H936) | ✓5) | – |
Output filter | ||||||||||||||||
Strengthened dv/dt output filter for max. 250/300 m (type-dependent). Design for longer motor cables available on request | L10 | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ❑ | ✓4) | ✓4) | ✓4) | ✓4) | ✓4) | ✓4) | ✓4) |
Sine-wave filter integrated in control cabinet or additional cabinet, suitable for motor frequencies of ≤ 75 Hz, voltage drop of approximately 10 % of line voltage | L14 | H916) | H926) | H926) | H926) | ✓5) | H916) | H926) | ✓5) | – | – | – | – | – | – | – |
Sine-wave filter integrated in control cabinet or additional cabinet, suitable for motor frequencies of ≤ 60 Hz, voltage drop of approximately 10 % of line voltage | L15 | – | – | – | – | – | – | – | – | ✓5) | ✓5) | ✓5) | ✓5) | ✓5) | ✓5) | ✓5) |
Standard accessories packages | ||||||||||||||||
Peripheral board 4 (G05) instead of peripheral board 2 (G03) (only in conjunction with package S01, S02, S03, S04, S08, S09, S11, S12) | G08 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package S01 with main switch, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch | S01 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package S02 with circuit breaker, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch | S02 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package with main switch, line contactor, board G03, local/remote switch | S03 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package with circuit breaker, line contactor, board G03, local/remote switch | S04 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package with main switch, line contactor, Calomat, RCU box connection | S06 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Bypass for smooth line synchronization (soft start function) incl. line-side main switch and contactors at the converter output and in bypass | S08 | H926) | H926) | H926) | H926) | ✓5) | H926) | H926) | ✓5) | H926) | H926) | H926) | ✓5) | ✓5) | ✓5) | ✓5) |
Bypass for smooth line synchronization (soft start function) incl. line-side circuit breaker and contactors at the converter output and in bypass | S09 | H926) | H926) | H926) | H926) | ✓5) | H926) | H926) | ✓5) | H926) | H926) | H926) | ✓5) | ✓5) | ✓5) | ✓5) |
Accessories package S11 with line-side main switch, board G03, local/remote switch | S11 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Accessories package S12 with line-side circuit breaker, board G03, local/remote switch | S12 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Bypass with line-side main switch, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch | S21 | H916) | H916) | H916) | H916) | ✓5) | H916) | H916) | ✓5) | H916) | H916) | H916) | ✓5) | ✓5) | ✓5) | ✓5) |
Bypass with line-side circuit breaker, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch | S22 | H916) | H916) | H916) | H916) | ✓5) | H916) | H916) | ✓5) |
Запрос коммерческого предложения× Сообщение отправлено× В ближайшее время сообщение будет обработано. Письмо с номером обращения отправлено на Ваш почтовый ящик. Спасибо за то, что выбрали Первый ZIP! Что-то пошло не так...× К сожалению, наша система расценила Ваше сообщение как спам. Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте. Приносим извинения за возможные неудобства. |