SIPLUS master interface modules for IM 151 CPU Siemens

Область применения



The master interface module adds a DP master interface to the IM 151-7(F-)CPU / IM 151-8(F) PN/DP CPU. A lower-level PROFIBUS DP line can thus be established. This results in the following advantages:

  • Offloading of the central controller by means of distributed preprocessing
  • IM 151-7 (F-)CPU / IM 151-8(F) PN/DP CPU is possible as DP master in stand-alone mode
  • Use of the CPU in hierarchical networks, e.g. with IE/PB Link also on Ethernet (CBA, etc.)

Обзор



PROFIBUS DP master interface module for interface module IM 151-7 (R) CPU / IM 151-8 (F) PN/DP CPU

  • Integrated 12 Mbit/s PROFIBUS DP master interface in Cu version
  • Allows parallel operation of two PROFIBUS DP interfaces on one IM 151-7 CPU
  • Allows operation of one PROFIBUS DP interface with an IM 151-8 (F) PN/DP CPU
  • Increase in availability of systems and machines
  • Functionality in accordance with a DP master configured interface of an S7-314 CPU

Programming is performed with STEP 7 from version V5.2 with Service Pack 1.

Note:

SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added.

 

SIPLUS master interface module for IM 151 CPU

Article No.

6AG1 138-4HA00-7AB0

BasedOn Article No.

6ES7 138-4HA00-0AB0

Ambient temperature range

-25 °C … +70 °C

Conformal coating

Coating of the printed circuit boards and the electronic components

Technical data

The technical data of the standard product applies except for the ambient conditions.

Ambient conditions

Relative humidity

100%, condensation/frost permitted. No commissioning in bedewed state.

Biologically active substances, compliance with EN 60721-3-3

Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

Chemically active substances, compliance with EN 60721-3-3

Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation!

Mechanically active substances, compliance with EN 60721-3-3

Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation!

Air pressure (depending on the highest positive temperature range specified)

1 080 ... 795 hPa (-1 000 … +2 000 m)

See ambient temperature range

795 ... 658 hPa (+2 000 ... +3 500 m)

derating 10 K
658 … 540 hPa (+3 500 … +5 000 m) derating 20 K



For technical documentation on SIPLUS, see:

http://www.siemens.de/siplus-extreme

Дизайн



The master interface module has a 9-pin Sub-D connector (socket) for connecting to PROFIBUS DP.

Installation information:
The master interface module is to be plugged in to the right of the IM 151-7 (F-) CPU / IM 151-8(F) PN/DP CPU.

Функции



The master interface module adds a DP master interface to the IM 151-7(F-)CPU / IM 151-8(F) PN/DP CPU. The functionality and quantity structures are defined by the IM 151-7 (F-)CPU / IM 151-8(F) PN/DP CPU.

The master interface module also enables connection of a programming device to its interface. This makes routing to bus nodes possible on the integral CPU interface possible if it is operated in active mode.

Технические данные



Order number

6AG1138-4HA00-7AB0

SIPLUS ET200S DP-MASTER INTERFACE

Hardware configuration

 

Number of modules per CPU

1

Ambient conditions

 

Ambient temperature during operation

 

  • min.

-40 °C; = Tmin

  • max.

70 °C; = Tmax

Extended ambient conditions

 

  • relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Запрос коммерческого предложения

×


    * Поля, обязательные для заполнения.

    Сообщение отправлено

    ×

    В ближайшее время сообщение будет обработано.

    Письмо с номером обращения отправлено на Ваш почтовый ящик.

    Спасибо за то, что выбрали Первый ZIP!

    Что-то пошло не так...

    ×

    К сожалению, наша система расценила Ваше сообщение как спам.

    Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте.

    Приносим извинения за возможные неудобства.