Antenna Connection System Siemens

Область применения
SIMATIC NET antenna connecting cables
- The flexible SIMATIC NET antenna connecting cables are required for connecting antennas with active devices.
- The cables offer low attenuation so that the quality of the radio signal is only minimally reduced.
- All antenna cables are flame-resistant, chemical-resistant and silicone-free.
- These cables are also suitable for railway applications and meet the increased requirements for environmental conditions and fire protection which are required for use in vehicles (including EN45545-2).
Lightning protection elements
- When remote antennas are used outdoors, there is a risk of lightning strikes
- A lightning protector can be used to prevent damage
Cabinet feedthroughs
Together with the antenna connecting cables, the cabinet feedthroughs enable simple connection of remote antennas to the active components located in the control cabinet/box.
Product versions
SIMATIC NET antenna connecting cables
- Pre-assembled cable lengths (0.3 m, 1 m, 2 m, 5 m and 10 m)
- Two different cable versions: Standard cables and cables suitable for railway applications
- Different connector types and combinations (N-Connect, SMA, QMA)
Lightning protection elements
- LP798-1N: Lightning protection element for N-Connect connections
- With gas discharge arrester for the frequency range 0 to 6 GHz for N-Connect connections
- Suitable for DC infeed via the antenna cable
Cabinet feedthroughs
- N-Connect female/N-Connect female without flange for panel thicknesses up to 4.5 mm
- Can also be used to connect two antenna connecting cables
Обзор
A coordinated range of coaxial accessories is offered for flexible combination and installation of the individual Remote Networks components both indoors and outdoors.
This range encompasses connecting cables as well as lightning protection elements and plug-in connectors.
Особенности
- Flexible use thanks to extensive, coordinated range
- Outdoor operation also possible with extended temperature range and protection against water and dust thanks to degree of protection IP65 or higher
- Components are suitable for use with SCALANCE M800, CP1242-7 und MD720 including national approvals
- Application in the railway environment can be implemented by using antenna connecting cables that are especially suitable for such applications.
Технические данные
Order number | 6XV1875-5AH10 | 6XV1875-5LH10 | |
---|---|---|---|
Product type designation | SIMATIC NET Antenna Connection Cable N-Connect Male/ Male | SIMATIC NET Antenna Connection Cable N-Connect/SMA Male/Male | |
Product description | Connecting cable for SIMATIC NET antennas, preassembled | Connecting cable for SIMATIC NET antennas, preassembled | |
Suitability for use | Flexible connecting cable for connecting an antenna or RCoax cable to a SCALANCE M/W | Flexible connecting cable for connecting an antenna to SCALANCE M | |
Cable length | 1 m | 1 m | |
Electrical data |
|
| |
Number of electrical connections | 2 | 2 | |
Type of electrical connection | N-Connect/N-Connect male/male | N-Connect/SMA male/male | |
Transmission frequency | 0 ... 6 000 MHz | 0 ... 6 000 MHz | |
Damping ratio per length |
|
| |
| 530 dB/km | 530 dB/km | |
| 830 dB/km | 830 dB/km | |
| 890 dB/km | 890 dB/km | |
Return loss minimum | 23 dB | 23 dB | |
Impedance |
|
| |
| 50 Ω | 50 Ω | |
Capacity per length at 1 kHz | 82 pF/m | 83 pF/m | |
Relative speed | 82 % | 82 % | |
Mechanical data |
|
| |
Design of the shield | Braided shield made of tin-plated copper wires | Braided shield made of tin-plated copper wires | |
Outer diameter |
|
| |
| 1.4 mm | 1.4 mm | |
| 3.8 mm | 3.8 mm | |
| 6.3 mm | 6.3 mm | |
Symmetrical tolerance of the outer diameter of cable sheath | 0.2 mm | 0.2 mm | |
Thickness of cable sheath | 0.76 mm | 1.76 mm | |
Material |
|
| |
| Cu | Cu | |
| polyethylene foam | polyethylene foam | |
| FRNC | FRNC | |
Color |
|
| |
| pastel turquoise | pastel turquoise | |
Bending radius |
|
| |
| 32 mm | 32 mm | |
| 45 mm | 45 mm | |
Tensile load maximum | 80 N | 80 N | |
Weight per length | 75 kg/km | 75 kg/km | |
Permitted ambient conditions |
|
| |
Ambient temperature |
|
| |
| -40 ... +80 °C | -40 ... +80 °C | |
| -40 ... +80 °C | -40 ... +80 °C | |
| -40 ... +80 °C | -40 ... +80 °C | |
| -25 ... +80 °C | -25 ... +80 °C | |
Chemical resistance |
|
| |
| conditional resistance | conditional resistance | |
Radiological resistance to UV radiation | resistant | resistant | |
Protection class IP | IP68; when plugged in | ; when plugged in | |
Product properties, functions, components general |
|
| |
Product property |
|
| |
| Yes | Yes | |
| Yes | Yes | |
Standards, specifications, approvals |
|
| |
Certificate of suitability |
|
| |
| Yes | Yes |
Order number | 6XV1875-5SH10 | 6XV1875-5UH10 | 6XV1875-5VH10 | |
---|---|---|---|---|
Product type designation | SIMATIC NET Antenna Connection Cable N-Connect Male/ Male | SIMATIC NET Antenna Connection Cable N-Connect/SMA Male/Male | SIMATIC NET Antenna Connection Cable QMA / N-Connect Male/Female | |
Product description | Connecting cable for SIMATIC NET antennas, preassembled | Connecting cable for SIMATIC NET antennas, preassembled | Connecting cable for SIMATIC NET antennas, preassembled | |
Cable length | 1 m | 1 m | 1 m | |
Electrical data |
|
|
| |
Number of electrical connections | 2 | 2 | 2 | |
Type of electrical connection | N-Connect/N-Connect male/male | N-Connect/SMA male/male | QMA/N-Connect male/female | |
Transmission frequency | 0 ... 6 000 MHz | 0 ... 6 000 MHz | 0 ... 6 000 MHz | |
Damping ratio per length |
|
|
| |
| 0.47 dB/m | 0.47 dB/m | 0.47 dB/m | |
| 0.77 dB/m | 0.77 dB/m | 0.77 dB/m | |
| 0.83 dB/m | 0.83 dB/m | 0.83 dB/m | |
Impedance |
|
|
| |
| 50 Ω | 50 Ω | 50 Ω | |
Capacity per length at 1 kHz | 80.2 pF/m | 80.2 pF/m | 80.2 pF/m | |
Relative speed | 83 % | 83 % | 83 % | |
Mechanical data |
|
|
| |
Outer diameter |
|
|
| |
| 1.4 mm | 1.4 mm | 1.4 mm | |
| 3.8 mm | 3.8 mm | 3.8 mm | |
| 5.5 mm | 5.5 mm | 5.5 mm | |
Symmetrical tolerance of the outer diameter of cable sheath | 0.1 mm | 0.1 mm | 0.1 mm | |
Color |
|
|
| |
| Black | Black | Black | |
Bending radius |
|
|
| |
| 25 mm | 25 mm | 25 mm | |
| 90 mm | 90 mm | 90 mm | |
Number of bending cycles | 50 | 50 | 50 | |
Weight per length | 47.8 kg/km | 47.8 kg/km | 47.8 kg/km | |
Permitted ambient conditions |
|
|
| |
Ambient temperature |
|
|
| |
| -30 ... +100 °C | -30 ... +100 °C | -30 ... +100 °C | |
| -30 ... +100 °C | -30 ... +100 °C | -30 ... +100 °C | |
| -30 ... +100 °C | -30 ... +100 °C | -30 ... +100 °C | |
Protection class IP | IP67; when plugged in | IP67; when plugged in | IP67; when plugged in | |
Product properties, functions, components general |
|
|
| |
Product property |
|
|
| |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
Standards, specifications, approvals |
|
|
| |
Certificate of suitability |
|
|
| |
| Yes | Yes | Yes |
Order number | 6GK5798-2LP00-2AA6 | |
---|---|---|
Product type designation | Lightning Protector LP798-1N | |
Interfaces |
| |
Number of electrical connections | 2 | |
Type of electrical connection | N-Connector | |
Design of plug-in connection | female / female | |
Electrical data |
| |
Transmission frequency | 0 ... 6 000 MHz | |
Impedance | 50 Ω | |
Permitted ambient conditions |
| |
Ambient temperature |
| |
| -40 ... +85 °C | |
| -40 ... +85 °C | |
| -40 ... +85 °C | |
Suitability for use |
| |
| Yes | |
| Yes | |
Protection class IP | IP67 | |
Design, dimensions and weight |
| |
Width | 54.8 mm | |
Diameter | 22.8 mm | |
Net weight | 50 g | |
Product properties, functions, components general |
| |
Product property silicon-free | Yes |
Order number | 6GK5798-2PP00-2AA6 | 6GK5798-0CP00-1AA0 | 6GK5898-1CV00-4AA0 | |
---|---|---|---|---|
Electrical data |
|
|
| |
Number of electrical connections | 2 | 2 | 2 | |
Type of electrical connection | N-Connect female/N-Connect female | N-Connect male/N-Connect male | ||
Transmission frequency | 0 ... 11 GHz | 0 ... 6 GHz | 0 ... 6 GHz | |
Impedance | 50 Ω | 50 Ω | 50 Ω | |
Return loss minimum | 0.1 dB | |||
Permitted ambient conditions |
|
|
| |
Ambient temperature |
|
|
| |
| -30 ... +100 °C | -40 ... +70 °C | -20 ... +80 °C | |
| -30 ... +100 °C | -40 ... +70 °C | -20 ... +80 °C | |
| -30 ... +100 °C | -40 ... +70 °C | -20 ... +80 °C | |
Protection class IP | IP68 | IP68 | ||
Запрос коммерческого предложения× Сообщение отправлено× В ближайшее время сообщение будет обработано. Письмо с номером обращения отправлено на Ваш почтовый ящик. Спасибо за то, что выбрали Первый ZIP! Что-то пошло не так...× К сожалению, наша система расценила Ваше сообщение как спам. Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте. Приносим извинения за возможные неудобства. |