SIPLUS MICROMASTER 420 Siemens

Обзор



General technical specifications of the SIPLUS MICROMASTER 420

Ambient temperature range

-10 ... +50 °C

Conformal Coating

Coating of the printed circuit board and the electronic components

Technical specifications

The technical specifications of the standard product apply with the exception of the ambient conditions.



Ambient conditions

Relative atmospheric humidity

5 … 100%,
condensation permissible



Application

The SIPLUS MICROMASTER 420 inverter is suitable for a variety of variable-speed drive applications. It is especially suitable for applications with pumps, fans and in conveyor systems.

It is the ideal cost-optimized frequency inverter solution. The inverter is especially characterized by its customer-oriented performance and ease-of-use. Its large range of line voltages enables it to be used all over the world.

Design

The SIPLUS MICROMASTER 420 inverter has a modular design. The operator panels and communication modules can be easily exchanged without the need for any tools.

Main features

  • Easy, guided commissioning
  • Modular construction allows maximum configuration flexibility
  • Three programmable isolated digital inputs
  • One analog input (0 to 10 V, scalable) can also be used as a 4th digital input
  • One programmable analog output (0 mA to 20 mA)
  • One programmable relay output
    30 V DC/5 A, resistive load
    250 V AC/2 A, inductive load
  • Low-noise motor operation through high pulse frequencies, adjustable (observe derating if necessary)
  • Protection for motor and inverter

Accessories (overview)

  • EMC filter, class A/B
  • LC filter
  • Line commutating reactors
  • Output reactors
  • Shield connection plates
  • Basic Operator Panel (BOP) for parameterizing the inverter
  • Plain-text Advanced Operator Panel (AOP) with multiple-language display
  • Plain-text Asian Advanced Operator Panel (AAOP) with Chinese and English display
  • Plain-text Cyrillic Advanced Operator Panel (CAOP) with Cyrillic, German and English display
  • Communication modules
    • PROFIBUS
    • DeviceNet
    • CANopen
  • PC connection kits
  • Mounting kits for installing the operator panels in control cabinet doors
  • PC commissioning programs under Windows 98/NT/2000/XP Professional
  • TIA integration with Drive ES

International standards

  • The MICROMASTER 420 inverter fulfills the requirements of the EU low-voltage directive
  • The MICROMASTER 420 inverter has CE marking.
  • Certified according to uL and c uL
  • c-tick

Mechanical characteristic data

  • Modular design
  • Operating temperature -10 °C to +50 °C (+14 °F to +122 °F)
  • Compact enclosure due to high power density
  • Simple cable connection, separate mains and motor connections for optimum electromagnetic compatibility
  • Plug-in operator panels
  • Screwless control terminal strip

Performance characteristic data

  • Latest IGBT technology
  • Digital microprocessor control
  • Flux current control (FCC) for enhanced dynamic response and optimized motor control
  • U/fcharacteristic linear
  • U/fcharacteristic quadratic
  • Multipoint characteristic (programmable U/fcharacteristic)
  • Flying restart
  • Slip compensation
  • Automatic restart after mains failure or operational fault
  • Simple process control
  • Parameterizable ramp-up/ramp-down times 0 s to 650 s
  • Ramp smoothing
  • Fast current limitation (FCL) for uninterrupted operation
  • Fast, reproducible response from the digital inputs
  • Precise setpoint input by means of a high-resolution 10-bit analog input
  • Compound braking for controlled rapid braking
  • 4 skip frequencies
  • Removable "Y" capacitor for use on IT networks (with ungrounded networks the "Y" capacitor must be removed and an output reactor installed)

Protection characteristic data

  • Overload current 1.5 x rated output current (i.e., 150% overload capability) for 60 s, cycle time 300 s
  • Overvoltage/undervoltage protection
  • Overtemperature protection for the inverter
  • Motor protection using a PTC connection via digital input (possible with supplementary circuit)
  • Ground-fault protection
  • Short-circuit protection
  • Thermal motor protection I2t
  • Motor blocking protection
  • Stall protection
  • Parameter locking