SINAMICS DCM demonstration case Siemens

Область применения


  • Demonstrating DC drives to customers
  • Training Siemens employees and customers
  • Test configurations

An automation group using a SIMATIC demonstration case together with one or several SINAMICS DC MASTER demonstration cases can be implemented.

Обзор



Demonstration case, opened

The SINAMICS DC MASTER demonstration model is installed ready to be connected-up in a rugged transport case and is immediately ready for operation. It comprises a DC converter 480 V 3 AC, 30 A DC, a 0.55 kW DC motor as well as numerous options and accessories. The case has two integrated transport wheels and a hinged handle.

Scope of delivery

The following main components are included in the SINAMICS DC MASTER demonstration case, including all of the required wiring, connection and signal cables:

  • DC converter 6RA8018‑6FV62‑0AA0‑Z; Z=G00+G10+G20+S01+L05
    G00 = Advanced CUD left
    G10 = Standard CUD right
    G20 = Communication Board CBE20 left
    S01 = memory card left
    L05 = electronics power supply for connection to 24 V DC

Option L05 permits operation on a three-phase line supply or a single-phase line supply, e.g. 230 V. Presentations or training courses can be carried out locally without requiring a three-phase supply; for instance in hotels or office buildings.

  • Terminal Module TM31
  • Terminal Module TM15
  • Advanced Operator Panel AOP30
  • Radio interference suppression filter
  • Three-phase commutating reactor for the armature circuit
  • Single-phase commutating reactor for the field circuit
  • DC motor 0.55 kW, 1 750 rpm
  • Pulse encoder OG 60 DN 2040 CI
  • Analog tachometer GT 5.05 L/410, Uo= 10 V/1 000 rpm
  • Commissioning box for SINAMICS DC MASTER to control analog and digital inputs and outputs

Free function blocks and Drive Control Chart can be used without any restrictions.

The demonstration case is also available without integrated DC motor to operate an externally mounted DC motor. (The rated converter data must be observed.)

Функции



Operator control

The converter can be operated from:

  • the commissioning box, which is connected to the terminals of the unit or the TM15 and TM31,
  • the AOP30 operator panel
  • the PROFIBUS interface
  • the PROFINET interface

A description is provided with the demonstration case. This clearly shows the principle operator panel design and the possible functions of the operator controls.
To use the STARTER commissioning tool, users require a programming device or PC. The system requirements are described in Chapter STARTER.

Технические данные



SINAMICS DCM demonstration case

Line connection

Supply voltage

110 … 480 V 3 AC (+15 %/-20 %)
or
110 … 480 V 1 AC (+15 %)

Rated frequency

45 … 65 Hz

Connecting cables

with 16 A Cecon connector (5UR5076 3), length approx. 4 m
and a 0.7 m long adapter cable with Cecon outlet and connector with ground connection

Line connection fusing required

16 A

Dimensions and weights

Width

Approx. 680 mm

Height

Approx. 700 mm

Depth

Approx. 430 mm

With integrated DC motor

Approx. 70 kg

Weight without motor

Approx. 55 kg