CP 440 Siemens

Область применения



The CP 440 communications processor is used for high-performance transmission of short message frames via RS 422/RS 485 (X27). This is the preferred method for implementing point-to-point connections.

Point-to-point connection is possible, for instance, for:

  • SIMATIC S7, SIMATIC S5 programmable logic controllers and third-party controllers
  • Programming devices and PCs
  • Robot controls
  • Scanners, barcode readers
  • Measuring systems
  • Scales

The RS 485 interface supports links to up to 32 partners.

Обзор


  • For high-performance transmission of messages via point-to-point connections (high message rate)
  • Physical interface: RS 422/RS 485 (X.27)
  • Up to 32 nodes
  • Protocol implemented: ASCII, 3964 (R)
  • Simple parameterization via a parameterization tool integrated into STEP 7

Дизайн



The communications processors have the following mechanical features:

  • Rugged plastic housing
  • LEDs:
    For "Send", "Receive” and ”Error”.

The CP 440 can also be used in expansion racks. However, transmission of the C bus signals must be ensured. A table with possible applications can be found under "Technical specifications".

Функции



A number of standard protocols are implemented and allow data exchange with a wide variety of nodes:

  • ASCII:
    For connection to third-party systems with simple communication protocols, such as protocols with start and end characters or protocols with block-check characters. The interface''s handshake signals can be scanned and controlled via the user program.
  • 3964 (R):
    For connection to Siemens devices or third-party devices by means of the standardized and published Siemens 3964 (R) protocol. Also implemented are a 3964(R) driver with default values and a programmable 3964(R) driver.

Parameterization

Parameterization of the CP 440 communications processor is particularly convenient and simple:

  • The user specifies module characteristics via a parameter assignment tool integrated in STEP 7, such as:
    • Which implemented protocol driver is to be used, or
    • Which driver-specific features are to be utilized
  • Parameterization via CPU:
    Simply connect the programming device to the CPU. The configuration data is filed in a system data block that is saved in the CPU. When a module is replaced, the new module is thus immediately ready for operation.
  • Configuring package (on CD-ROM):
    With electronic manual, parameterization screen forms and standard function block for communication with the CP

Технические данные



Order number

6ES7440-1CS00-0YE0

CP 440-1, PTP-CONNECTIONS, 1 CHANNEL

Supply voltage

 

Rated value (DC)

  • 5 V DC

Yes

  • 24 V DC

Yes

Input current

 

from backplane bus 5 V DC, max.

360 mA

Power loss

 

Power loss, typ.

1.7 W

Memory

 

Memory requirements per interface in memory card of S7-CPU

1 to 5 Kbytes for parameters

Interfaces

 

Number of interfaces

1

Interface (physical) RS 422/485 (X.27)

Yes

RS 422/RS 485, cable length shielded, max.

1 200 m

Point-to-point

 

Integrated protocol driver

 

  • 3964 (R)

Yes

  • ASCII

Yes

Transmission rate, RS 422/485

 

  • with 3964 (R) protocol, max.

115.2 kbit/s

  • with ASCII protocol, max.

115.2 kbit/s

Configuration

 

Configuration software

 

  • STEP 7

Yes; own parameter assignment forms

Dimensions

 

Width

25 mm

Height

290 mm

Depth

210 mm

Weights

 

Weight, approx.

600 g