Basic Line Modules Siemens

Обзор



Basic Line Modules are available for applications in which no energy is returned to the supply or where the energy exchange between motor and generator axes takes place in the DC link. The connected Motor Modules are pre-charged via the thyristor gate control. Basic Line Modules are designed for connection to grounded TN/TT and non-grounded IT supply systems.

A Braking Module of the appropriate frame size can be integrated into a Basic Line Module in order to permit, in conjunction with an external braking resistor, regenerative operation of the drive system (→ DC link components).

Дизайн



The Basic Line Modules have the following interfaces as standard:

  • 1 line supply connection
  • 1 connection for the 24 V DC electronics power supply
  • 1 DC link connection (DCP, DCN) for supplying the connected Motor Modules
  • 1 DC link connection (DCPA, DCNA) for connecting a Braking Module
  • 3 DRIVE-CLiQ sockets
  • 1 temperature sensor input (KTY84-130, PTC or Pt100)
  • 1 PE/protective conductor connection

The status of the Basic Line Modules is indicated via two multicolor LEDs.

The scope of supply of the Basic Line Modules includes:

  • DRIVE-CLiQ cable for connecting to a CU320-2 or SIMOTION D4x5 Control Unit
  • DRIVE-CLiQ cable to connect the Control Unit to the first Motor Module

Интеграция



The Basic Line Modules communicate with the higher-level control module via DRIVE-CLiQ. The control module in this case can be a CU320-2 or a SIMOTION D Control Unit. An external 24 V DC power supply is required to operate Basic Line Modules.

Connection example of a Basic Line Module

Технические данные



General technical specifications

Electrical specifications

Line power factor
with rated power

 
  • Basic fundamental (cos φ1)

> 0.96

  • Total (λ)

0.75 … 0.93

Efficiency

> 99 %

DC link voltage, approx. 1)

1.35 × line voltage under partial load
1.32 × line voltage under full load

Main contactor control

 
  • Terminal block-X9/5-6

240 V AC, max. 8 A
30 V DC, max. 1 A

Conformity

CE (EMC Directive No. 2004/108/EC and Low-Voltage Directive No. 2006/95/EC)

Approvals, according to

cULus (only for drive units connected to line voltages 380 ... 480 V 3 AC and 500 ... 600 V 3 AC)



1) The DC link voltage is unregulated and load-dependent. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 380 … 480 V 3 AC

Basic Line Modules

 

6SL3330-1TE34-2AA3

6SL3330-1TE35-3AA3

6SL3330-1TE38-2AA3

6SL3330-1TE41-2AA3

6SL3330-1TE41-5AA3

Rated power

      
  • For IN DC (50 Hz 400 V)

kW

200

250

400

560

710

  • For IH DC (50 Hz 400 V)

kW

160

200

315

450

560

  • For IN DC (60 Hz 460 V)

hp

305

385

615

860

1090

  • For IH DC (60 Hz 460 V)

hp

245

305

485

690

860

DC link current

      
  • Rated current IN DC

A

420

530

820

1200

1500

  • Base load current IH DC 1)

A

328

413

640

936

1170

  • Maximum current Imax DC

A

630

795

1230

1800

2250

Input current

      
  • Rated current IN E

A

365

460

710

1010

1265

  • Maximum current Imax E

A

547

690

1065

1515

1897

Current demand

      
  • 24 V DC auxiliary power supply

A

1.1

1.1

1.1

1.1

1.1

DC link capacitance

      
  • Basic Line Module

μF

7200

9600

14600

23200

29000

  • Drive line-up, max.

μF

57600

76800

116800

185600

232000

Power loss, max. 2)

      
  • At 50 Hz 400 V

kW

1.9

2.1

3.2

4.6

5.5

  • At 60 Hz 460 V

kW

1.9

2.1

3.2

4.6

5.5

Cooling air requirement

m3/s

0.17

0.17

0.17

0.36

0.36

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

66/68

66/68

66/68

71/73

71/73

Line supply connection

U1, V1, W1

 

M10 screw

M10 screw

M10 screw

3 × M12 screw

3 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

6 × 185

6 × 185

DC link connection

DCP, DCN

 

M10 screw

M10 screw

M10 screw

3 × hole for M12

3 × hole for M12

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

6 × 185

6 × 185

PE/GND connection

 

2 × hole for M10

2 × hole for M10

2 × hole for M10

2 × hole for M12

2 × hole for M12

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

4 × 240

4 × 240

Cable length, max. 3)

      
  • Shielded

m

2600

2600

2600

4000

4000

  • Unshielded

m

3900

3900

3900

6000

6000

Degree of protection

 

IP00

IP00

IP00

IP00

IP00

Dimensions

      
  • Width

mm

310

310

310

310

310

  • Height

mm

1164

1164

1164

1653

1653

  • Depth

mm

352

352

352

550

550

Weight, approx.

kg

96

96

96

214

214

Frame size

 

FB

FB

FB

GB

GB



1) The base load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.

2) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

3) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 500 … 690 V 3 AC

Basic Line Modules

 

6SL3330-1TG33-0AA3

6SL3330-1TG34-3AA3

6SL3330-1TG36-8AA3

6SL3330-1TG41-1AA3

6SL3330-1TG41-4AA3

Rated power

      
  • For IN DC (50 Hz 690 V)

kW

250

355

560

900

1100

  • For IH DC (50 Hz 690 V)

kW

195

280

440

710

910

  • For IN DC (50 Hz 500 V)

kW

175

250

390

635

810

  • For IH DC (50 Hz 500 V)

kW

165

235

365

595

755

  • For IN DC (60 Hz 575 V)

hp

250

350

600

900

1250

  • For IH DC (60 Hz 575 V)

hp

200

300

450

800

1000

DC link current

      
  • Rated current IN DC

A

300

430

680

1100

1400

  • Base load current IH DC 1)

A

234

335

530

858

1092

  • Maximum current Imax DC

A

450

645

1020

1650

2100

Input current

      
  • Rated current IN E

A

260

375

575

925

1180

  • Maximum current Imax E

A

390

563

863

1388

1770

Current demand

      
  • 24 V DC auxiliary power supply

A

1.1

1.1

1.1

1.1

1.1

DC link capacitance

      
  • Basic Line Module

μF

3200

4800

7300

11600

15470

  • Drive line-up, max.

μF

25600

38400

58400

92800

123760

Power loss, max. 2)

      
  • At 50 Hz 690 V

kW

1.5

2.1

3.0

5.4

5.8

  • At 60 Hz 575 V

kW

1.5

2.1

3.0

5.4

5.8

Cooling air requirement

m3/s

0.17

0.17

0.17

0.36

0.36

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

66/68

66/68

66/68

71/73

71/73

Line supply connection

U1, V1, W1

 

M10 screw

M10 screw

M10 screw

3 × M12 screw

3 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

6 × 185

6 × 185

DC link connection

DCP, DCN

 

M10 screw

M10 screw

M10 screw

3 × M12 screw

3 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

6 ×185

6 × 185

PE/GND connection

 

2 × hole M10

2 × hole M10

2 × hole M10

2 × hole M12

2 × hole M12

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

4 × 240

4 × 240

Cable length, max. 3)

      
  • Shielded

m

1500

1500

1500

2250

2250

  • Unshielded

m

2250

2250

2250

3375

3375

Degree of protection

 

IP00

IP00

IP00

IP00

IP00

Dimensions

      
  • Width

mm

310

310

310

310

310

  • Height

mm

1164

1164

1164

1653

1653

  • Depth

mm

352

352

352

550

550

Weight, approx.

kg

96

96

96

214

214

Frame size

 

FB

FB

FB

GB

GB



1) The base load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.

2) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

3) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.