SIPLUS S7-400 IM 460-0 Siemens

Область применения
The IM 460-0 interface module is intended for use as a send IM for central connection over short distances of up to 5 m. It transfers data from both the P-bus and the C-bus to the expansion racks.
The IM 460-0 is intended for use only in association with the IM 461-0 interface module (in the expansion racks).
Обзор
- Send interface module for centralized expansion up to 5 m
- Transfer from P and K Bus
- Plug into central controller
- You may connect up to 8 expansion units (max. 4 per port)
- Usable exclusively with IM 461-0
Note:
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added.
Technical documentation on SIPLUS can be found here:
http://www.siemens.de/siplus-extreme
Дизайн
The IM 460-0 interface module can be inserted into the following central controllers:
- UR1,
- UR2 and
- CR2.
Up to 8 expansion units can be connected (up to 4 per interface). Up to 6 IM 460-0 units can be plugged in per central controller.
The module has:
- 3 LEDs for indicating faults.
- 2 interfaces for connecting the expansion lines via 468-1 connecting cable.
Технические данные
Order number | 6AG1460-0AA01-2AB0 | |
|---|---|---|
SIPLUS S7-400 IM460-0 TX | ||
Input current |
| |
from backplane bus 5 V DC, max. | 140 mA | |
Power loss |
| |
Power loss, max. | 700 mW | |
Hardware configuration |
| |
Cable length between first and last interface module, max. | 5 m | |
Ambient conditions |
| |
Ambient temperature during operation |
| |
| -25 °C; = Tmin | |
| 60 °C; = Tmax | |
Extended ambient conditions |
| |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity |
| |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance |
| |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
| Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Dimensions |
| |
Width | 25 mm | |
Height | 290 mm | |
Depth | 217 mm | |
Weights |
| |
Weight, approx. | 600 g | |






Ответ от производителя может занять до 5 дней и более.