Lutze — . A3311812 - LÜTZE SILFLEX® Tray-ER TPE with UL/TC-ER/WTTC/MTW/CE Approvals

Наличие
Цена
Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.
Ответим на Ваш запрос завтра 01.11.2025 в течение дня.
Доставка
- транспортной компанией на Ваш выбор
- самовывоз из офиса в Санкт-Петербурге
- бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
- Part No. - A3311812 - Type - SI N(C)TPE TRAY-ER (12×AWG18) SW - LÜTZE SILFLEX® Tray-ER TPE with UL/TC-ER/WTTC/MTW/CE Approvals - Flexible Tray Cable · Shielded - Symbols - Application - Shielded multi-conductor cable for tray applications, with exposed run (open wiring) approvalCompliant with NFPA 79 for machine tool wiringTC-ER for use with cable trays without conduit, which can reduce material and labor costsMetal cutting equipment, machine tools, machine and plant construction, HVAC technology, assembly and production lines, and other industrial applicationsWTTC – wind turbine tray cable rating for use in wind power generationDry, damp and wet locations - Characteristics - Flexible design with Nylon for crush impact resistance per UL 1277 and easy installationSpecially formulated TPE jacket for superior oil resistanceCutting oil resistant – mineral & bio/vegetable based oil *specially tested with plant based cutting oilSunlight resistantDirect burialUL Type TC-Exposed RunTalc freeSilicone free 
- Description - SILFLEX (C) TRAY-ER TPE - Number of conductors/cross-section - (12×AWG18) - Jacket material - TPE - Jacket color - black RAL 9005 - Outer Ø - 12,2 mm - Outer Ø - 0,479 inches - Weight - 176 Lbs/Mft - Cu-Index - 85 Lbs/Mft - Element construction - AWG18/12C - Conductor construction - AWG 18 (16/30) - Conductor - AWG conductorCU-wire bare - Conductor category - fine wire - Conductor marking - blackwith white number printgreen/yellow - Conductor insulation - PVC/NylonTHHN – THWN - Drain wire - CU-wire tin-plated - Overall shield - Aluminium laminate Foil shieldBraid shieldTinned copper wires - Jacket characteristics - Oil resistantSilicone-freemineral oil-resistantbio-oil-resistant - Rated voltage - 600 V TC-ER 90C600 V MTW 90C1000 V WTTC 90C600 V UL AWM 105 °C - Temperature range fixed - -40 °C … +90 °C - Minimum bending radius fixed - 6×D - Element construction - AWG18/12C - Approvals - TC-ERcURuscULusUL Type MTW or DP-1WTTCClass 1 Div. 2 per NECArt. 336, 392, 501cUL TCCIC FT4UL 1277 - Conformity - CEREACHRoHS - Oil resistant according to - Oil Res IIOil Res I - Note - CE These products are in conformity with the EU Low Voltage Directive 2014/35/EU 
- Технические данные - a3311812-luetze-silflex-tray-er-tpe-us-data-sheet-009785920.pdf 
 
                        





 Ответ от производителя может занять до 5 дней и более.
Ответ от производителя может занять до 5 дней и более.