Артикул: 949933
Тип расширенного изделия: MS116-25-HKF1-11
Идентификационный номер изделия: 1SAM250005R1014
Европейский товарный код (EAN): 4013614405631
Описание в каталоге: MS116-25-HKF1-11 Manual Motor Starter
Длинное описание: The MS116-25-HKF1-11 manual motor starter is a compact 45 mm width devices with a rated operational current of Ie = 25.0 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949935
Тип расширенного изделия: MS116-32-HKF1-11
Идентификационный номер изделия: 1SAM250005R1015
Европейский товарный код (EAN): 4013614405648
Описание в каталоге: MS116-32-HKF1-11 Manual Motor Starter
Длинное описание: The MS116-32-HKF1-11 manual motor starter is a compact 45 mm width devices with a rated operational current of Ie = 32.0 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1006381
Extended Product Type:CK1-11
Product ID:1SAM301901R1001
EAN:4013614403927
Catalog Description:CK1-11 Short Circuit Signaling Contact
Long Description:CK1-11 Short-Circuit Signal Contact 2 NO
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949942
Тип расширенного изделия: MS132-0.16T
Идентификационный номер изделия: 1SAM340000R1001
Европейский товарный код (EAN): 4013614484919
Описание в каталоге: MS132-0.16T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-0.16T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.16 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949945
Тип расширенного изделия: MS132-0.25T
Идентификационный номер изделия: 1SAM340000R1002
Европейский товарный код (EAN): 4013614484926
Описание в каталоге: MS132-0.25T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-0.25T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.25 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949948
Тип расширенного изделия: MS132-0.4T
Идентификационный номер изделия: 1SAM340000R1003
Европейский товарный код (EAN): 4013614484933
Описание в каталоге: MS132-0.4T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-0.4T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949951
Тип расширенного изделия: MS132-0.63T
Идентификационный номер изделия: 1SAM340000R1004
Европейский товарный код (EAN): 4013614484940
Описание в каталоге: MS132-0.63T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-0.63T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.63 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949954
Тип расширенного изделия: MS132-1.0T
Идентификационный номер изделия: 1SAM340000R1005
Европейский товарный код (EAN): 4013614484957
Описание в каталоге: MS132-1.0T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-1.0T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 1.0 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949957
Тип расширенного изделия: MS132-1.6T
Идентификационный номер изделия: 1SAM340000R1006
Европейский товарный код (EAN): 4013614484964
Описание в каталоге: MS132-1.6T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-1.6T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 1.6 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949970
Тип расширенного изделия: MS132-2.5T
Идентификационный номер изделия: 1SAM340000R1007
Европейский товарный код (EAN): 4013614484971
Описание в каталоге: MS132-2.5T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-2.5T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 2.5 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949981
Тип расширенного изделия: MS132-4.0T
Идентификационный номер изделия: 1SAM340000R1008
Европейский товарный код (EAN): 4013614484988
Описание в каталоге: MS132-4.0T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-4.0T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 4.0 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949984
Тип расширенного изделия: MS132-6.3T
Идентификационный номер изделия: 1SAM340000R1009
Европейский товарный код (EAN): 4013614484995
Описание в каталоге: MS132-6.3T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-6.3T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 6.3 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949960
Тип расширенного изделия: MS132-10T
Идентификационный номер изделия: 1SAM340000R1010
Европейский товарный код (EAN): 4013614485008
Описание в каталоге: MS132-10T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-10T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 10 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949967
Тип расширенного изделия: MS132-16T
Идентификационный номер изделия: 1SAM340000R1011
Европейский товарный код (EAN): 4013614485022
Описание в каталоге: MS132-16T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-16T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 16 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949963
Тип расширенного изделия: MS132-12T
Идентификационный номер изделия: 1SAM340000R1012
Европейский товарный код (EAN): 4013614485015
Описание в каталоге: MS132-12T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-12T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 12 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949973
Тип расширенного изделия: MS132-20T
Идентификационный номер изделия: 1SAM340000R1013
Европейский товарный код (EAN): 4013614485039
Описание в каталоге: MS132-20T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-20T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 20 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949976
Тип расширенного изделия: MS132-25T
Идентификационный номер изделия: 1SAM340000R1014
Европейский товарный код (EAN): 4013614485046
Описание в каталоге: MS132-25T Circuit Breaker for Primary Transformer Protection
Длинное описание: The circuit breaker for transformer protection MS132-25T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 25 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 50 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949940
Тип расширенного изделия: MS132-0.16
Идентификационный номер изделия: 1SAM350000R1001
Европейский товарный код (EAN): 4013614400018
Описание в каталоге: MS132-0.16 Manual Motor Starter
Длинное описание: The MS132-0.16 manual motor starter is a compact 45 mm width devices with a rated operational current of Ie = 0.16 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949943
Тип расширенного изделия: MS132-0.25
Идентификационный номер изделия: 1SAM350000R1002
Европейский товарный код (EAN): 4013614400025
Описание в каталоге: MS132-0.25 Manual Motor Starter
Длинное описание: The MS132-0.25 manual motor starter is a compact 45 mm width devices with a rated operational current of Ie = 0.25 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 949946
Тип расширенного изделия: MS132-0.4
Идентификационный номер изделия: 1SAM350000R1003
Европейский товарный код (EAN): 4013614400032
Описание в каталоге: MS132-0.4 Manual Motor Starter
Длинное описание: The MS132-0.4 manual motor starter is a compact 45 mm width devices with a rated operational current of Ie = 0.40 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and the trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.