1SBL411501R8400 ABB A75-22-00 110V 50Hz / 110-120V 60Hz Contactor - A75-22-00 110V 50Hz / 110-120V 60Hz SST1SBL411501R8400
Наличие
Цена
Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.
Ответим на Ваш запрос сегодня в течение дня.
Доставка
- транспортной компанией на Ваш выбор
- самовывоз из офиса в Санкт-Петербурге
- бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Ordering
Minimum Order Quantity 1 piece Customs Tariff Number 85364900 Popular Downloads
Data Sheet, Technical Information 1SBC100122C0202_Ch02 Instructions and Manuals FPTC407701P0003 Dimensions
Product Net Width 92 mm Product Net Depth 119.5 mm Product Net Height 110 mm Product Net Weight 1.400 kg Technical
Number of Main Contacts NO 2 Number of Main Contacts NC 2 Number of Auxiliary Contacts NO 0 Number of Auxiliary Contacts NC 0 Standards Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1 Rated Operational Voltage Main Circuit 1000 V Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A Rated Operational Current AC-1 (Ie) (690 V) 40 °C 125 A (690 V) 55 °C 105 A (690 V) 70 °C 85 A Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3 Rated Making Capacity AC-3 acc. to IEC 60947-4-1 10 x Ie AC-3 Short-Circuit Protective Devices gG Type Fuses 160 A Rated Short-time Withstand Current (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A Maximum Electrical Switching Frequency AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 600 cycles per hour Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V Rated Impulse Withstand Voltage (Uimp) 8 kV Mechanical Durability 10 million Maximum Mechanical Switching Frequency 3600 cycles per hour Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C Rated Control Circuit Voltage (Uc) 50 Hz 110 V 60 Hz 110 … 120 V Coil Consumption Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W Average Holding Value 50 / 60 Hz 18 V·A Average Holding Value 50 / 60 Hz 5.5 W Average Pull-in Value 50 Hz 190 V·A Average Pull-in Value 60 Hz 180 V·A Operate Time Between Coil Energization and NO Contact Closing 8 ... 27 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Connecting Capacity Main Circuit Flexible with Cable End 6 ... 16 mm² Rigid Cable 6 ... 25 mm² Connecting Capacity Auxiliary Circuit Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm² Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 Connecting terminals (delivered in open position) Main poles M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector Terminal Type Screw Terminals Environmental
Ambient Air Temperature Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C Close to Contactor for Storage -60 ... +80 °C Climatic Withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II Maximum Operating Altitude Permissible 3000 m Resistance to Shock acc. to IEC 60068-2-27 Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g RoHS Status Following EU Directive 2002/95/EC August 18, 2005 and amendment Container Information
Package Level 1 Units 1 piece Package Level 1 Width 142 mm Package Level 1 Length 190 mm Package Level 1 Height 136 mm Package Level 1 Gross Weight 1.4 kg Package Level 1 EAN 3471522096845 Package Level 2 Units 63 piece Classifications
Object Classification Code Q ETIM 4 EC000066 - Magnet contactor, AC-switching ETIM 5 EC000066 - Magnet contactor, AC-switching ETIM 6 EC000066 - Power contactor, AC switching UNSPSC 39121529
О компании ABB
ABB – высокотехнологичная компания, лидирующая в разработке систем автоматизации промышленных производств. Её история началась ещё 130 лет назад, и сейчас филиалы ABB работают в 100 странах, а количество служащих превышает 135,000 человек.
Уже более 40 лет специалисты ABB занимаются разработкой инновационных технологий цифрового соединения и управления промышленным оборудованием и системами. За это время на предприятиях заказчиков были установлены и введены в эксплуатацию 70,000 систем управления, объединяющие более 70 миллионов устройств.
Каждый день компания выпускает новые решения безопасности, эффективности и продуктивности для коммунальной и промышленной сферы, транспорта и инфраструктуры по всему миру.
Вся продукция, системы и комплексные решения ABB разрабатываются с заботой об окружающей ... Читать далее...






Ответ от производителя может занять до 5 дней и более.