Long Description:1 change over and 1 closing contact for each Push Button. Good marking possibilities. Nominal voltage of LED: 24 V ac/dc (operates 8 - 30 V ac/dc, britghtness changes). Loading capacity of switch (max)42 V ac / 60 V dc, 250 mA ac/dc, 6 VA / 4 W.
Long Description:1 change over and 1 closing contact for each Push Button. Good marking possibilities. Nominal voltage of LED: 24 V ac/dc (operates 8 - 30 V ac/dc, britghtness changes). Loading capacity of switch (max)42 V ac / 60 V dc, 250 mA ac/dc, 6 VA / 4 W.
Long Description:4/2-gang push button panel to control bistable relays or electronic control systems. Load capacity 1A AC/DC. White LED-light with adjustable illumination. Installation on surface or on top of a standard flush mounting box.
Long Description:Signal Push Button with LED. Adressed / non-adressed function. Good marking possibilities. Operating voltage 9,5 - 28 V ac / 9,5 - 35 V dc. Current consumption: 20 mA ac / 10 mA dc. Switching voltage / -current / -power: 30 V ac / 35 V dc / 100 mA ac/dc / 3 VA/W.
Long Description:Signal Push Button with LED. Additional plug for 6.3 mm Jack connector. Adressed / non-adressed function available. Good marking possibilities. Operating voltage: 9,5-28 Vac / 9,5-35 Vdc. Current consumption: 20 mA ac / 10 mA dc. Switching voltage / -current / -power: 30 Vac/35 Vdc / 100 mA ac/dc / 3 VA/W.
Long Description:The loop controls itself against short circuits and breaks. Possibility to connect both closing and opening potential free contacts. Input delay 150 ms / 2,5 s. Memory / no memory function. Potential free output. Cancelling button with LED. Good marking possibilities on the button and name plate._x000D_Operating voltage: 15 - 28 V ac / 18 - 35 V dc. Current consumption: 70 mA ac / 40 mA dc.
Long Description:The loop controls itself against short circuits and breaks. Possibility to connect both closing and opening potential free contacts. Input delay 150 ms / 2,5 s. Memory/no memory function. Potential free output. Cancelling button with LED. Good marking possibilities on the button and name plate. Operating voltage: 15 - 28 V ac / 18 - 35 V dc. Current consumption: 110 mA ac / 60 mA dc.
Long Description:As FEH1001, but instead of a Push Button equipped with a Switch._x000D_The loop controls itself against short circuits and breaks. Possibility to connect both closing and opening potential free contacts. Input delay 150 ms / 2,5 s. Memory/no memory function. Potential free output. Cancelling button with LED. Operating voltage: 15 - 28 V ac / 18 - 35 V dc. Current consumption: 70 mA ac / 40 mA dc. Good marking possibilities on the button and name plate._x000D_
Long Description:The loop controls itself against short circuits and breaks. Possibility to connect both closing and opening contacts. Input Memory / no memory. Potential free output. External cancelling with closing / opening contact. Operating voltage: 15 - 28 V ac / 18 - 35 V dc. Current Consumption: 110 mA ac / 60 mA. Sound intensity / frequency: 78 dB / 2,3 kHz (Intensity measured at 30 cm distance).
Long Description:The Leak Guard unit operates as the standard Control Unit FEH1001, with the exception that the loop monitors leakage current (10 µA). Tape sensors, conduit pairs or other leakage sensors could be connected to the device. Memory/no memory function. Potential free output. Cancelling button with LED. Operating voltage: 9.5 - 28 V ac / 9.5 - 35 V dc. Current consumption: 75 mA ac / 40 mA dc. Good marking possibilities on the button and name plate.
Long Description:Two audio frequencies available. Volume adjustment possible. Operating voltage: 9,5 - 28 V ac / 9,5 - 35 V dc. Current consumption: 20 mA ac / 10 mA dc. Sound intensity / frequency: 70 dB / 250 Hz or 70 dB / 750 Hz (intensity measured at 30 cm distance).
Long Description:With red flashing light. Interrupting sound. Operating voltage: 9,5 - 28 V ac / 9,5 - 35 V dc. current consumption: 60 mA ac / 30 mA dc. Sound intensity / frequency: 78 dB / 2,3 kHz (intensity measured at a 30 cm distance). Sound disconnectable.
Long Description:With yellow flashing light. Interrupting sound. Operating voltage: 9,5 - 28 V ac / 9,5 - 35 V dc. current consumption: 60 mA ac / 30 mA dc. Sound intensity / frequency: 78 dB / 2,3 kHz (intensity measured at a 30 cm distance). Sound disconnectable.
Long Description:Could be used as an 3/6 points alarm receiving panel in calling and alarm systems. With 6 LED's. Good marking possibilities. Operating voltage: 12 - 24 V ac/dc. Current consumption/LED: 4 mA ac / 7 mA dc.
Long Description:A device including a push button as well as a buzzer. The LED of the push button and the buzzer operates in parallel. The buzzer can be cancelled with the push button. When cancelled the LED remains on till the alarm goes off. Good marking possibilities on the push button and the name plate. Operating voltage 9,5 - 28 Vac / 9,5 - 35 Vdc. Current consumption: 45 mA ac / 35 mA dc. Load capacity of the switch: 42 Vac / 60 Vdc, 250 mA ac/dc, 6 VA / 4 W
Long Description:Used to control lighting, heating, alarm lights, magnetic valves etc. Controlled by low voltage potential free contact (e.g. switches, push buttons, potential free contacts or alarm panels). the relay provides protection between low- and high voltage circuits. Separate transformer not needed. Loading capacity: 10 A / 230 V ac. Fluorescent light load max 300 VA.