Catalog Description:6173/11 U-500 Combined actuator, Flush-mounted bus coupler, flush-mounted actuators
Long Description:For controlling blind or awning motors. For connecting the thermoelectric actuating drives 6164/10 101. 1 electronic output (noiseless) The bus can be connected via enclosed terminal block.
Long Description:Power adapter for the power supply of Busch-ComfortTouch® 8136/09-… and 8136/12-…. With integrated KNX bus coupler for the establishment of the local bus connection to the ABB i-bus® KNX. With integrated audio outputs (LineOut).
Catalog Description:6190/41 Wind Velocity transmitter, Physical sensors, weather station
Long Description:For Weather Station 6190/40-101. Serves for converting the detected wind velocity (0.7-40 m/s) into electrical signals (0-10 V). With PTC heating element for winter operation (in combination with filament transformer 6190/49). Incl. 3 m supply lead LIYY 6 x 0.25 mm²
Catalog Description:6190/42 Temperature-value transmitter, Physical sensors, weather station
Long Description:For Weather Station 6190/40-101. Serves for converting the measured temperature (-30 to +70 degrees) into electrical signals (0-10 V). Recommended supply lead 3 x 0.25 mm² (max. 100 m)
Catalog Description:6190/43 Rain sensor, Physical sensors, weather station
Long Description:For Weather Station 6190/40-101. Serves for converting the detected rain into electrical signals (0 V=dry - 10 V=rain). Heating 6190/49 required Incl. 3 m supply lead LIYY 5 x 0.25 mm²
Catalog Description:6190/44 Twilight value sensor, Physical sensors, weather station
Long Description:For Weather Station 6190/40-101. Serves for converting the measured light value (0-255 lux) into electrical signals (0-10 V). Surface mounting box IP 65 Recommended supply lead 3 x 0.25 mm² (max. 100 m)
Catalog Description:6190/45 Brightness-value transmitter, Physical sensors, weather station
Long Description:For Weather Station 6190/40-101. Serves for converting the measured light value (3,000-60,000 lux) into electrical signals (0-10 V). Surface mounting box IP 65 Recommended supply lead 3 x 0.25 mm² (max. 100 m)
Long Description:Multichannel universal dimming actuator for controlling incandescent lamps, 230 V incandescent halogen lamps, low-voltage halogen lamps with conventional or electronic transformers, and dimmable energy-saving halogen lamps. Optimized for dimming of Philips retrofit LEDs (LEDi). Increasing the max. load via channel bridging possible. The outputs can be switched parallel in any combination. Outputs automatically recognise the connected load. In addition, the operating mode can be selected manually. Status indication of the channels via LED. Direct manual operation with / without KNX voltage connected or in an unprogrammed status possible. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.).
Catalog Description:6197/13-101-500 Universal dimming actuator 4 x 315 W/VA to 1 x 1260 W/VA, MDRC universal dimming actuators
Long Description:Multichannel universal dimming actuator for controlling incandescent lamps, 230 V incandescent halogen lamps, low-voltage halogen lamps with conventional or electronic transformers, and dimmable energy-saving halogen lamps. Optimized for dimming of Philips retrofit LEDs (LEDi). Increasing the max. load via channel bridging possible. The outputs can be switched parallel in any combination. Outputs automatically recognise the connected load. In addition, the operating mode can be selected manually. Status indication of the channels via LED. Direct manual operation with / without KNX voltage connected or in an unprogrammed status possible. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.).
Long Description:Multichannel universal dimming actuator for controlling incandescent lamps, 230 V incandescent halogen lamps, low-voltage halogen lamps with conventional or electronic transformers, and dimmable energy-saving halogen lamps. Optimized for dimming of Philips retrofit LEDs (LEDi). Increasing the max. load via channel bridging possible. The outputs can be switched parallel in any combination. Outputs automatically recognise the connected load. In addition, the operating mode can be selected manually. Status indication of the channels via LED. Direct manual operation with / without KNX voltage connected or in an unprogrammed status possible. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.).
Long Description:Multichannel universal dimming actuator for controlling incandescent lamps, 230 V incandescent halogen lamps, low-voltage halogen lamps with conventional or electronic transformers, and dimmable energy-saving halogen lamps. Optimized for dimming of Philips retrofit LEDs (LEDi). Increasing the max. load via channel bridging possible. The outputs can be switched parallel in any combination. Outputs automatically recognise the connected load. In addition, the operating mode can be selected manually. Status indication of the channels via LED. Direct manual operation with / without KNX voltage connected or in an unprogrammed status possible. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.).
Long Description:Universal dimming actuator for controlling incandescent lamps, 230 V tungsten halogen lamps, low-voltage halogen lamps with conventional or electronic transformers, and dimmable energy-saving halogen lamps. Outputs automatically recognise the connected load. In addition, the operating mode can be selected manually. Status indication of the channels via LED. Direct manual operation with / without KNX voltage connected or in an unprogrammed status possible. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.).
Long Description:Universal dimming actuator for controlling incandescent lamps, 230 V tungsten halogen lamps, low-voltage halogen lamps with conventional or electronic transformers, and dimmable energy-saving halogen lamps. Outputs automatically recognise the connected load. In addition, the operating mode can be selected manually. Status indication of the channels via LED. Direct manual operation with / without KNX voltage connected or in an unprogrammed status possible. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.).
Catalog Description:SU-F-1.0.1 Sensor unit, 1gang, Sensors, room temperature controllers, movement detector, fan coils
Long Description:For transmitting switching, push-button, dimming and blind commands to an ABB-free@home® actuator. For contacting 1gang rocker 6230-10-xxx, 6231-10-xxx, 6232-10-xxx, 6233-10-xxx und 6234-10-xxx. The bus can be connected via enclosed terminal block.
Catalog Description:SU-F-2.0.1 Sensor unit, 2gang, Sensors, room temperature controllers, movement detector, fan coils
Long Description:For transmitting switching, push-button, dimming and blind commands to an ABB-free@home® actuator. For contacting 2gang rocker 6230-2x-xxx, 6231-2x-xxx, 6232-2x-xxx, 6233-2x-xxx and 6234-2x-xxx. The bus can be connected via enclosed terminal block.
Long Description:For the central control of up to 16 configurable ABB-free@home® functions. For the display of configurable system messages. A configurable primary function can be triggered with a multi-touch gesture. Capacitive touch screen with closed glass surface. With integrated room temperature controller and temperature sensor. In connection with temperature sensor 6226/T the integrated room temperature controller can be fitted with a remote sensor. Suitable as room temperature controller extension unit (up to 8). Requires additional power supply 24 VDC, e.g. 6358-101. Display size: 10.9 cm (4.3'') Display resolution: 480 x 854 Mounting height: 8 mm
Long Description:For the central control of up to 16 configurable ABB-free@home® functions. For the display of configurable system messages. A configurable primary function can be triggered with a multi-touch gesture. Capacitive touch screen with closed glass surface. With integrated room temperature controller and temperature sensor. In connection with temperature sensor 6226/T the integrated room temperature controller can be fitted with a remote sensor. Suitable as room temperature controller extension unit (up to 8). Requires additional power supply 24 VDC, e.g. 6358-101. Display size: 10.9 cm (4.3'') Display resolution: 480 x 854 Mounting height: 8 mm
Catalog Description:RTC-F-1 Room thermostat, Sensors, room temperature controllers, movement detector, fan coils
Long Description:Heating/cooling operation. Control element with room temperature controller function for controlling commercially available actuating drives in connection with 6254/0.6, 6254/0.12. With display of set-value temperature. For contacting cover plate 6235-XX or 6236-xx The bus can be connected via enclosed terminal block.
Long Description:For switching 127 V~/230 V~ consumers. With integrated switch actuator. Switching function is available also without prior programming (pre-configured). Configuration can be changed later via the web interface (groups, scenes, etc.). For contacting 1gang rocker 6230-10-xxx, 6231-10-xxx, 6232-10-xxx, 6233-10-xxx und 6234-10-xxx. The bus can be connected via enclosed terminal block. When installing in the flush-mounted box, a spatial division between the bus cable and 127 V/230 V installation cable is to be adhered to! If this minimum distance is not possible, use electronic boxes or insulating tubes.