Описание в каталоге: OS600J04FP Fusible disconnect switch
Длинное описание: Including terminal bolt kit, a black ON-OFF plastic handle and shaft as standard. The handle is IP65, NEMA 1, 3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths. Fuse standards UL 248.
Описание в каталоге: OS600J04N2P Fusible disconnect switch
Длинное описание: Including terminal bolt kit, a black ON-OFF plastic handle and shaft as standard. The handle is IP65, NEMA 1, 3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths. Fuse standards UL 248.
Описание в каталоге: OS600J12P Fusible disconnect switch
Длинное описание: Including terminal bolt kit, a black ON-OFF plastic handle and shaft as standard. The handle is IP65, NEMA 1, 3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths. Fuse standards UL 248.
Описание в каталоге: OS600J40FP Fusible disconnect switch
Длинное описание: Including terminal bolt kit, a black ON-OFF plastic handle and shaft as standard. The handle is IP65, NEMA 1, 3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths. Fuse standards UL 248.
Длинное описание: Including a black handle OHB65J6 with I-0 and ON-OFF -indication (IP65) and a shaft OXP6X161 (length 161 mm, mounting depth H=141…260 mm). Protected tunnel terminals, IP20, cable size 2.5…25 mm2. Terminal shroud OSS63G1 needed for maintaining IP20 rating for wire sizes <10mm2, (AWG 14 - 4). Fuse standards CSA C22.2 No 106, IEC 60269-2-1 Sec. II (Dimensions).
Длинное описание: Including a black handle OHB65J6 with I-0 and ON-OFF -indication (IP65) and a shaft OXP6X161 (length 161 mm, mounting depth H=141…260 mm). Protected tunnel terminals, IP20, cable size 2.5…25 mm2. Terminal shroud OSS63G1 needed for maintaining IP20 rating for wire sizes <10mm2, (AWG 14 - 4). Fuse standards CSA C22.2 No 106, IEC 60269-2-1 Sec. II (Dimensions).
Длинное описание: Including black handle with I-0 and ON-OFF -indication (IP65) and a shaft. Mounting depths measured from the left side of the switch, 3-pole:H=221…283 mm and 4-pole:H= 266...328 mm. Protected tunnel terminals, IP20, cable size 2.5…25 mm2. Terminal shroud OSS63G1 needed for maintaining IP20 rating for wire sizes <10mm2, (AWG 14 - 4). Fuse standards CSA CS40.2 No 106, IEC 60269-2-1SEC II (Dimensions).
Длинное описание: Including black handle with I-0 and ON-OFF -indication (IP65) and a shaft. Mounting depths measured from the left side of the switch, 3-pole:H=221…283 mm and 4-pole:H= 266...328 mm. Protected tunnel terminals, IP20, cable size 2.5…25 mm2. Terminal shroud OSS63G1 needed for maintaining IP20 rating for wire sizes <10mm2, (AWG 14 - 4). Fuse standards CSA CS40.2 No 106, IEC 60269-2-1SEC II (Dimensions).
Длинное описание: Including black handle with I-0 and ON-OFF -indication (IP65) and a shaft. Mounting depths measured from the left side of the switch, 3-pole:H=221…283 mm and 4-pole:H= 266...328 mm. Protected tunnel terminals, IP20, cable size 2.5…25 mm2. Terminal shroud OSS63G1 needed for maintaining IP20 rating for wire sizes <10mm2, (AWG 14 - 4). Fuse standards CSA CS40.2 No 106, IEC 60269-2-1SEC II (Dimensions).
Описание в каталоге: OS60GJ03P Fusible disconnect switch
Длинное описание: Including terminal bolt kit, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.
Описание в каталоге: OS60GJ04FP Fusible disconnect switch
Длинное описание: Including terminal bolt kit, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.