Multifunctional safety solutions DOLD

Показано товаров: 6 из 46
Артикул: 1324813
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact
• Parallel connection of several SAFEMASTER M-systems possible
• The functions are selected via rotary switch
- 1 Emergency stop circuit, 2-channel
- 2 Emergency stop circuits, single-channel
- 1 Emergency stop circuit, 2-channel + 1 stop single channel
• Auto or manual start
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Overvoltage and undervoltage monitoring function with error indication
• Permanently monitored feedback loop to connect external contactors
• Broken wire and short circuit monitoring function with error indication
• Width: 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324812
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Category 4 to EN 954-1
• Functions selectable via rotational switches to connect max.:
- 8 E-stop circuits, single channel or
- 4 E-stop circuits, 2-channel or
- 4 light curtains or
- 2 light curtains and 1 E-stop circuit or
- 4 safety gates or
- 2 safety gates and 1 E-stop circuit or
- 4 pairs of 2-hand-buttons or Typ III A according to DIN EN 547 or
- 2 pairs of 2-hand-buttons Typ III C according to DIN EN 547
and 1 E-stop circuit
• In addition selectable:
- auto or manual reset (simulation input for gate monitor)
- continuously monitored feedback circuit to monitor external
contactors
• Cross fault detection
• Short circuit and broken wire detection
• Outputs:
- 3 NO or 2 NO and 1 NC contacts
- 2 semiconductor outputs short circuit proof and overload
protected
• Under- and overvoltage detection and signalling
• LED indication for operation (RUN), channel 1/2
• 45 mm width
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324811
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: max. 4 NO instantaneous semiconductor monitoring output
• LED indicator for operation, delay contects and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324810
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: 2 NO instantaneous contact and 2 NO contacts delayed
• 1 semiconductor output for instantaneous contacts
1 semiconductor output for delayed contacts
• LED indicator for operation, safety function, time delay and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324809
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: max. 4 NO instantaneous semiconductor monitoring output
• LED indicator for operation, delay contects and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324808
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: 2 NO contacts per safety function
• 1 semiconductor output per safety function
• LED indicator for operation, safety function 1, 2 and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину

Multifunctional safety solutions save space and costs

Alongside a multitude of monofunctional safety switching devices, DOLD also offer high-performance multifunctional safety switching devices and systems. In doing so, DOLD integrates increasing functionality with constantly sinking space requirements. The multifunctional safety switching devices offer you optimal solutions for many areas of use in machinery and system construction. SAFEMASTER C, which is configurable without additional hardware, is one option here just like the modular safety system SAFEMASTER M, which allows you a cost-effective and software-free adjustment of the safety functions to the respective task. With SAFEMASTER PRO, you receive a safety system that you can tailor to the application using variable expansion modules.