Safety switching devices DOLD

    Показано товаров: 17 из 37
    Артикул: 1324755
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508
    - Directive 2014/33/EU for elevators
    • Output: 3 NO contacts, 1 NC contact
    • Single or 2-channel operation
    • Line fault detection on On-button
    • Manual restart or automatic restart, switch S2
    • With or without cross fault monitoring in the loop, switch S1
    • LED indicator for state of operation
    • LED indicator for channel 1 and 2
    • Degree of protection IP40; can be mounted in cabinets and installations
    with lower degree of protection without additional measures
    (depending on ambient conditions)
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or
    2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • As option with pluggable terminal blocks for easy exchange of devices
    - with screw terminals
    - or with cage clamp terminals
    • Width 22.5 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324754
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Category 4 to EN 954-1
    • BN 5930.48/203 with cross fault detection by connecting
    2 different phases, max. 400 V,
    BN 5930.48/204 with cross fault detection by connecting
    phase and neutral, max. 230 V
    • Dual voltage version
    • Emergency-stop circuit T12, T22:
    optionally for AC 110 V / DC 60 V or AC 230 V / DC 110 V
    • Output: 3 NO, 1 NC contacts for AC 400 V
    • 1-channel or 2-channel circuit
    • LED displays for channel 1, 2 and mains
    • Feedback circuit X1 - X2 for monitoring external contactors
    • Removable terminal strips
    • Width 100 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324753
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Category 4 to EN 954-1
    • BN 5930.48/203 with cross fault detection by connecting
    2 different phases, max. 400 V,
    BN 5930.48/204 with cross fault detection by connecting
    phase and neutral, max. 230 V
    • Dual voltage version
    • Emergency-stop circuit T12, T22:
    optionally for AC 110 V / DC 60 V or AC 230 V / DC 110 V
    • Output: 3 NO, 1 NC contacts for AC 400 V
    • 1-channel or 2-channel circuit
    • LED displays for channel 1, 2 and mains
    • Feedback circuit X1 - X2 for monitoring external contactors
    • Removable terminal strips
    • Width 100 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324752
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL 3) to IEC/EN 61508
    - Category 4 to EN 954-1
    • E-stop with latching function
    • Automatic start when voltage returns after phase failure
    when no E-Stop was operated before phase failure.
    • Reset after E-stop with push button
    • Output max. 3 NO contacts, see contacts
    • B_ 5903._ _ /00000: 1 E-stop loop 2-channel operated
    • B_ 5903._ _ /00020: 2 E-stop loops single channel operated
    • Cross fault monitoring
    • Feedback loop for external contact reinforcement
    • Short circuit and broken wire detection on all inputs
    • LED indication for channel 1 and 2 and for diagnostics
    • Removable terminal strips
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or
    2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • BH 5903: width 45 mm
    BL 5903: width 90 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324751
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL 3) to IEC/EN 61508
    - Category 4 to EN 954-1
    • E-stop with latching function
    • Automatic start when voltage returns after phase failure
    when no E-Stop was operated before phase failure.
    • Reset after E-stop with push button
    • Output max. 3 NO contacts, see contacts
    • B_ 5903._ _ /00000: 1 E-stop loop 2-channel operated
    • B_ 5903._ _ /00020: 2 E-stop loops single channel operated
    • Cross fault monitoring
    • Feedback loop for external contact reinforcement
    • Short circuit and broken wire detection on all inputs
    • LED indication for channel 1 and 2 and for diagnostics
    • Removable terminal strips
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or
    2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • BH 5903: width 45 mm
    BL 5903: width 90 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324750
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511
    • Output: 3 NO or 2 NO, 1 NC instantaneous contacts and
    3 NO release delayed contacts
    • Single and 2-channel operation
    • Line fault detection on On-button,
    when On-button is connected to S33-S34
    • Manual restart with button on S33-S34 or automatic restart with
    bridge between S13-S14
    • With or without cross fault monitoring in the E-stop loop
    • LED indication for supply, channel 1/2 and release delayed contacts
    • Removable terminal strips
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or
    2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • Width
    BH 5928: 45 mm
    BI 5928: 67.5 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324749
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511
    • Output: 3 NO or 2 NO, 1 NC instantaneous contacts and
    3 NO release delayed contacts
    • Single and 2-channel operation
    • Line fault detection on On-button,
    when On-button is connected to S33-S34
    • Manual restart with button on S33-S34 or automatic restart with
    bridge between S13-S14
    • With or without cross fault monitoring in the E-stop loop
    • LED indication for supply, channel 1/2 and release delayed contacts
    • Removable terminal strips
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or
    2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • Width
    BH 5928: 45 mm
    BI 5928: 67.5 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324748
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
    • Output: 2 NO instantaneous contacts and 1 release delay contact
    • 1- or 2-channel connection
    • Line fault detection at the ON pushbuttons at connection on
    terminals S33-S34
    • Manual restart with button on S33-S34 or automatic restart with
    bridge between S13-S34
    • With or without cross fault monitoring in the E-stop loop
    • Indication for released time circuit
    • LED indication for supply, channel 1/2 and release delayed contacts
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • As option with pluggable terminal blocks for easy exchange of devices
    - with screw terminals
    - or with cage clamp terminals
    • Width 22.5 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324747
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL 3) to IEC/EN 61508
    • 1- or 2-channel connection
    • Operating state display
    • LED display for channels 1 and 2
    • Overvoltage and short circuit protection
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or
    2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • Output: optionally 1 NO / 1 NC or 3 NO / 1 NC contacts
    • Optionally automatic ON function or activation via the ON pushbutton
    • With fast auto start as option
    • Width 45 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324746
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508
    • Output: 3 NO, 1 NC contacts for AC 400 V
    • Optionally gold-plated contacts to switch small loads (input for PLC)
    • 1-channel or 2-channel connection
    • LED displays for channels 1 and 2
    • Feedback circuit X3 - X4 for monitoring external contactors
    • Removable terminal strips
    • Overvoltage and short circuit protection
    • Width 100 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324745
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508
    • Output: max. 3 NO contacts, see contacts
    • Single and 2-channel operation
    • Line fault detection on On-button
    • Manual restart or automatic restart, switch S2
    • With or without cross fault monitoring in the E-stop loop, switch S1
    • LED indicator for channel 1 and 2 and Power
    • Removable terminal strips
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • Width 22.5 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324744
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508
    • Output: 2 NO contacts for AC 250 V
    • 1-channel or 2-channel connection
    • LED displays for channels 1 and 2
    • Overvoltage and short circuit protection
    • Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or
    2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • Width 45 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324743
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
    • 1- or 2-channel operation
    • Output: 1 NO contact and 1 semiconductor monitoring output
    • LED-indicator for relay 1 / 2 and supply voltage
    • Width 17.5 mm and 64 mm depth
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324742
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508
    • According to EN 50156-1 for furnaces
    • Single channel or two-channel operation
    • Output: max. 4 NO contacts
    • AC 230 V model with galvanic separation
    • LED indicator for channel 1 / 2 and state of operation
    • Short circuit detection between terminal Y1 and common
    • BG 5924 with:
    - Removable terminal strips
    - Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • BG 5924: width 22.5 mm
    • IP 5924: width 70 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324740
    • According to
    - Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
    - SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
    - Safety Integrity Level (SIL 2) to IEC/EN 61508
    • Single channel operation
    • Output: max. 4 NO contacts
    • AC 230 V model with galvanic separation
    • LED indicator for channel 1 / 2 and state of operation
    • Short circuit detection between terminal Y1 and common
    • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
    2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
    • as option with pluggable terminal blocks for easy exchange
    of devices
    - with screw terminals
    - or with cage clamp terminals
    • Width 22.5 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324741
    • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508
    • According to EN 50156-1 for furnaces
    • Single channel or two-channel operation
    • Output: max. 4 NO contacts
    • AC 230 V model with galvanic separation
    • LED indicator for channel 1 / 2 and state of operation
    • Short circuit detection between terminal Y1 and common
    • BG 5924 with:
    - Removable terminal strips
    - Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
    DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
    • BG 5924: width 22.5 mm
    • IP 5924: width 70 mm
    В корзину

    Товар в корзине.

    Перейти в корзину
    Артикул: 1324738
    • According to
    -- Performance Level (PL) e and category 4 to EN ISO 13849-1
    -- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    -- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
    • According to EN 50156-1 for furnaces
    • 2-channel operation
    • Forcibly guided output contacts
    • With or without cross fault monitoring in the E-stop loop, switch S1
    • Manual restart or automatic restart, switch S2
    • LED indicator for channel 1, 2 and Netz
    • Width 17,5 mm
    В корзину

    Товар в корзине.

    Перейти в корзину

    The suitable solution for every challenge

    Safety switching devices from the DOLD SAFEMASTER family monitor various safety functions such as emergency stop, two-hand switching, safety mat, light barrier and more. From the monofunctional safety switching devices to the multifunctional modular safety system with field bus connection, all products serve a single purpose: the uncompromising protection of people and machinery. Manufacturers and operators of machines and systems are faced with the challenge of developing and/or operating safety-oriented switching devices that must meet numerous regulations. DOLD supports you with sample-tested modules you can use to realise function- and cost-optimal solutions.

    Свяжитесь с нами

    Если вы не нашли нужной информации на сайте или у вас остались вопросы по товарам, оставьте заявку на бесплатную консультацию, и мы вам перезвоним