FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 0.70...1.00 A 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
LOAD FEEDER FUSELESS DIRECT START,AC 400V, SZ. S00, 0.9...1.25A, 4KW, 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 0.90...1.25 A 24 V DC SPRING-TYPE TERMINALS FOR STANDARD RAIL MOUNTING, (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 0.90...1.25 A 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
LOAD FEEDER FUSELESS DIRECT START,AC 400V, SZ. S00, 1.1...1.6A, 4KW, 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 1.10...1.60 A 24 V DC SPRING-TYPE TERMINALS FOR STANDARD RAIL MOUNTING, (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 1.10...1.60 A 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
LOAD FEEDER FUSELESS DIRECT START,AC 400V, SZ. S00, 1.4...2A, 4KW, 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 1.40...2.00 A 24 V DC SPRING-TYPE TERMINALS FOR STANDARD RAIL MOUNTING, (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 1.40...2.00 A 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
LOAD FEEDER FUSELESS DIRECT START,AC 400V, SZ. S00, 1.8...2.5A, 4KW, 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 1.80...2.50 A 24 V DC SPRING-TYPE TERMINALS FOR STANDARD RAIL MOUNTING, (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 1.80...2.50 A 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
LOAD FEEDER FUSELESS DIRECT START,AC 400V, SZ. S00, 2.2...3.2A, 4KW, 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 2.20...3.20 A 24 V DC SPRING-TYPE TERMINALS FOR STANDARD RAIL MOUNTING, (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 2.20...3.20 A 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
LOAD FEEDER FUSELESS DIRECT START,AC 400V, SZ. S00, 2.8 ... 4A 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 2NO+2NC PLUGGED ONTO CONTACTOR 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 2.80...4.00 A 24 V DC SPRING-TYPE TERMINALS FOR STANDARD RAIL MOUNTING, (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 2.80...4.00 A 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED)
LOAD FEEDER FUSELESS DIRECT START,AC 400V, SZ. S00, 4.5...6.3A, 4KW, 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)