EMERGENCY POWER SUPPLY NV24/110 WITH CHARGER AND 2 ACCUS 12V/2.2AH FOR SUPPLY OF 8022 EVALUATION UNITS WITH 24V DC EMERGENCY SUPPLY POWER SUPPLY: 110V AC OUTPUT: 24V DC; HOUSING FOR RAIL MOUNTING 35MM
MINIATURE FIELD DISTRIBUTOR KFV1 TO ACCOMMODATE ONE 8022 EVALUATION UNIT, INCLUDING INSTALLATION AND WIRING; PROTECTION RATING: IP54 DIMENSIONS: 180X254X110MM
MINIATURE FIELD DISTRIBUTOR KFV2 TO ACCOMMODATE TWO 8022 EVALUATION UNIT, INCLUDING INSTALLATION AND WIRING; PROTECTION RATING: IP54 DIMENSIONS: 360X254X110MM
EXMONITOR TOX O2-25 GAS DETECTOR FOR OXYGEN DEFICIENCY, VERSION FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384 MEASURING PRINCIPLE: ELECTROCHEM. CELL; MEASURING RANGE: 0-25% VOL O2 LINEAR OUTPUT SIGNAL 4-20MA TWO-WIRE-SYSTEM 24V DC; POWER SUPPLY FROM EVALUATION UNIT 8022 HOUSING MATERIAL: GRP IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
EXMONITOR TOX CO-1000 GAS DETECTOR FOR CARBON MONOXIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-300PPM CO OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
EXMONITOR TOX H2S-50 GAS DETECTOR FOR HYDROGEN SULFIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-50PPM H2S OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
EXMONITOR TOX H2S-100 GAS DETECTOR FOR HYDROGEN SULFIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-100PPM H2S OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
EXMONITOR TOX CL2-20 GAS DETECTOR FOR CHLORINE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-10PPM CL2 OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
EXMONITOR TOX H2-1000 GAS DETECTOR FOR HYDROGEN, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-1000PPM H2 OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
EXMONITOR TOX HCN-100 GAS DETECTOR FOR HYDROGEN CYANIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-100PPM HCN OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
EXMONITOR TOX CL2-20 GAS DETECTOR FOR CHLORINE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-10PPM CL2 OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER