MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19, 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SENSITIVE EARTH CURRENT TRANSF. SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19, 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SENSITIVE EARTH CURRENT TRANSF. SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SENSITIVE EARTH CURRENT TRANSF. SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 48BI, 21BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 48BI, 21BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SENSITIVE EARTH CURRENT TRANSF. SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19, 48BI, 21BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM