Timers DOLD
Timers off delayed (21)
Cycling timers (6)
Timers on delayed (27)
Multifunction relays (10)
Flasher (8)
• Time range up to 32 h
• Seperate setting of impulse- and space time
• For impulse- and space time 4 time ranges each
• Repeat accuracy < ± 0.5 %
• Setting on relative scale
• Dual-voltage-version
• Programmable for start with impulse or space
• LED indication for operation and contact position
• BA 7864 available with remote potentiometer contact Z1-Z2, Z3-Z4
• EO 7864 with 11-pole socket
• Available with 1 or 2 changeover contacts,
or semiconductor output (BA 7864)
• BA 7864: width 45 mm
EO 7864: front size 35 x 48 mm
• With 10 time ranges from 0.05 s ... 300 h
• Impulse and break time separately adjustable
• Selectable start with impulse or break
• AC/DC 24 ... 240 V
• Control input for interruption of the time elapse
• LED indication for voltage supply and contact position
• Flashing function during elapse of time
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Impulse and break time separately adjustable
• Selectable start with impulse or break
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• LED indicators for operation, contact position and time delay
• 1 changeover contact
• As option connection of 2 remote potentiometers 10 kΩ
• Devices available in 2 enclosure versions:
IK 7854: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according to
DIN 43 880
SK 7854: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct
• 17.5 mm width
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Impulse and break time separately adjustable
• Selectable start with impulse or break
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• LED indicators for operation, contact position and time delay
• 1 changeover contact
• As option connection of 2 remote potentiometers 10 kΩ
• Devices available in 2 enclosure versions:
IK 7854: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according to
DIN 43 880
SK 7854: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct
• 17.5 mm width
• Time delay up to 100 s
• Repeat accuracy < ± 0.5 %
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
• Time ranges up to 100 s
• Repeat accuracy ≤ 0.5 % + 10 ms
• 2-voltage design
• LED indicators for contact position
• 1 NO contact fleeting make
1 NO contact operate delayed
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• Converts pulses to selectable length
• No repeat control during the time period (of the pulse)
• Pulse lengthening / shortening
• Time range up to 60 min
• Repeat accuracy ≤ ± 1 %
• Setting on aboslute scale
• 2-voltage version
• LED displays for availability and contact position
• Available with 1 or 2 changeover contacts
• Width 22.5 mm
• Programmable: fleeting on make, fleeting on break,
fleeting on make and brake
• Fleeting time 0.3 ... 0.6 s fixed
• Repeat accuracy < ± 5 %
• LED indication for supply and contact position
• 2-wire-proximity sensor control
• Available with 1 or 2 changeover contacts
• Width 22.5 mm
• Fleeting action 0.05 ... 1 s, adjustable
• Fleet make contact
• Repeat accuracy ≤ 0.5 % + 10 ms
• Pushbutton for manual actuation of the contact
• 1 changeover contact for 16 A
• Width 17.5 mm
• Fleeting time up to 60 min.
• Adjustable fleeting time
• Repeat accuracy ≤ ± 1 %
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7815: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7815: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• RK 7813, RK 7815, RK 7816: Time ranges up to 10 h
• RK 7814: 4 time ranges up to 16 h
• LED indicator for state of contact
• Dual-voltage-version AC 230 V + AC/DC 24 V or
AC 110 ... 127 V + AC/DC 24 V
• 1 changeover contact
• As option units with second changeover contact
(only for voltage AC 230 V + AC/DC 24 )
- on delayed
- as instantaneous contact
• Start with impuls only for version RK 7816
• Start with space only for version RK 7816._ _ /_10
• As option with plug in terminal blocks for
exchange of devices, available
- with screw terminals
- with cage clamp terminals
• Width: 17.5 mm
• Fleeting time up to 60 min.
• Adjustable fleeting time
• Repeat accuracy ≤ ± 1 %
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7815: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7815: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Fleeting make
• Fleeting time up to 300 s or on request
• Repeat accuracy < ± 0,5 %
• Setting on absolute scale
• Available as 2-voltage version
• LED displays for availability and contact position
• 2 fleeting make or
1 fleeting make and 1 non-delayed changeover contact
• Also available with instantaneous contact
• Also available with CSA approval
• Width 22.5 mm
• Fleeting action
• Repeat time adjustable to 100 s
• Repeat accuracy ≤ 0.5 % + 10 ms
• Dual voltage supply
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• Delay up to 180 s
• Repeat accuracy < ± 5 %
• 1 changeover contact delayed, 1 changeover contact without delay
• Width 45 mm
• For delay up to 99.99 h
• Repeat accuracy < ± 0.5 %
• LED indicators for power supply and state of contact
• As option with time progression indication
• As option 1 or 2 changeover contacts or semiconductor outputs
• 48 x 72 mm front surface
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm

Safe relays for applications with high demands
DOLD has been a renowned, innovative manufacturer in the field of timer technology for decades that has continued to set standards with its developments. Time relays, that is, relays with specific time response, help you to cost-effectively realised start-up and shut-down delays in industry and building technology. The timer technology from DOLD includes both electro-mechanical and electro-pneumatic time relays as well as electronic devices on the basis of modern microprocessor technology.