Data transmission/control components Leuze
Power supply (14)
Data transmission (108)
- The DDLS 500 is a data transmission photoelectric sensor that, in addition to a high transmission rate of 100 Mbit/s, sets new standards – above all with respect to usability.
- The DDLS 500 is a data transmission photoelectric sensor that, in addition to a high transmission rate of 100 Mbit/s, sets new standards – above all with respect to usability.
- The DDLS 500 is a data transmission photoelectric sensor that, in addition to a high transmission rate of 100 Mbit/s, sets new standards – above all with respect to usability.
- The DDLS 500 is a data transmission photoelectric sensor that, in addition to a high transmission rate of 100 Mbit/s, sets new standards – above all with respect to usability.
- The MSI-CM safety relay is used as a contact extension module in accordance with DIN EN 60204‑1/VDE 0113 Part 1 for contact extension for E-Stop relays and two-hand control units. Depending on the wiring and proper integration of the feedback path, a Performance Level PL e in accordance with EN ISO 13849‑1 is achieved.
- The MSI-CM safety relay is used as a contact extension module in accordance with DIN EN 60204‑1/VDE 0113 Part 1 for contact extension for E-Stop relays and two-hand control units. Depending on the wiring and proper integration of the feedback path, a Performance Level PL e in accordance with EN ISO 13849‑1 is achieved.
- This safety relay with adjustable delay time is equipped with two release current paths which release undelayed in accordance with stop category 0. Two additional release current paths release in accordance with stop category 1 with adjustable delay time.
- This safety relay with adjustable delay time is equipped with two release current paths which release undelayed in accordance with stop category 0. Two additional release current paths release in accordance with stop category 1 with adjustable delay time.
- The MSI-SR4 is used for evaluating safety-sensor input signals. Light curtains, E-Stop buttons and Safety Switches, for example, can thereby be integrated in the machine process in a safety-oriented manner.
- The MSI-SR4 is used for evaluating safety-sensor input signals. Light curtains, E-Stop buttons and Safety Switches, for example, can thereby be integrated in the machine process in a safety-oriented manner.
- Two devices can be connected to the MSI-SR5 safety relay, either with two transistor OSSDs or by designing as a two-channel contact circuit. As a result, two sensors can be connected to a common switch-off circuit – for applications up to Performance Level PLe acc. to EN ISO 13849-1.
- Two devices can be connected to the MSI-SR5 safety relay, either with two transistor OSSDs or by designing as a two-channel contact circuit. As a result, two sensors can be connected to a common switch-off circuit – for applications up to Performance Level PLe acc. to EN ISO 13849-1.
- With the MSI-RM2 relay module, a compact and – at the same time – economical solution is available in combination with safety sensors for applications up to Performance Level PLe. The relay module, only 17.5 mm wide, has two potential-free make contact circuits with a response time of only 10 ms.
- With the MSI-RM2 relay module, a compact and – at the same time – economical solution is available in combination with safety sensors for applications up to Performance Level PLe. The relay module, only 17.5 mm wide, has two potential-free make contact circuits with a response time of only 10 ms.
- The MSI-2H is the link between two-hand command devices and the machine control. The device checks the simultaneous activation of the two, 2-channel buttons and ensures a controlled process start. The module is used everywhere that feeding-in is not automatic, but rather has to be performed manually by people.
- The MSI-2H is the link between two-hand command devices and the machine control. The device checks the simultaneous activation of the two, 2-channel buttons and ensures a controlled process start. The module is used everywhere that feeding-in is not automatic, but rather has to be performed manually by people.
- MSI-TRM is a safety monitoring device for the evaluation of one-channel testable optoelectronic protective devices of type 4 acc. to EN IEC 61496. Up to six type 4 sensors can be connected to the device.
- MSI-TRM is a safety monitoring device for the evaluation of one-channel testable optoelectronic protective devices of type 4 acc. to EN IEC 61496. Up to six type 4 sensors can be connected to the device.
- MSI-T is a safety monitoring device for the periodic testing of one-channel testable Optoelectronic Protective Devices of type 2 acc. to EN IEC 61496. Up to six type 2 sensors can be connected to the device in daisy chain.
- MSI-T is a safety monitoring device for the periodic testing of one-channel testable Optoelectronic Protective Devices of type 2 acc. to EN IEC 61496. Up to six type 2 sensors can be connected to the device in daisy chain.

Свяжитесь с нами
Если вы не нашли нужной информации на сайте или у вас остались вопросы по товарам, оставьте заявку на бесплатную консультацию, и мы вам перезвоним








Ответ от производителя может занять до 5 дней и более.

