SPECTRALPYROMETER PA30AF4 ARDOCELL, MEASURING RANGE 500-2500 CEL, DISTANCE RATIO 55:1 (90%), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,78-1,06 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
SPECTRALPYROMETER PA35AF4 ARDOCELL, MEASURING RANGE 600-3000 CEL, DISTANCE RATIO 55:1 (90%), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,85-0,91 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA40AF4 ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 150:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA40AF5 ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 140:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA43AF5 ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=330:1,DH=45:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 7:1
SPECTRALPYROMETER PA20AF6 ARDOCELL, MEASURING RANGE 350-2500 CEL, DISTANCE RATIO 150:1 (90%), FOCAL RANGE 0,2 M..0,4 M, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA40AF6 ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 240:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA80AF6 ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 240:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA40AF7 ARDOCELL, MEASURING RANGE 850-3000 CEL, DISTANCE RATIO 150:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA43AF7 ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=350:1,DH=50:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 7:1
SPECTRALPYROMETER PA20AF8 ARDOCELL, MEASURING RANGE 350-2500 CEL, DISTANCE RATIO 40:1 (90%), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA40AF8 ARDOCELL, MEASURING RANGE 850-3000 CEL, DISTANCE RATIO 140:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA40AF9 ARDOCELL, MEASURING RANGE 850-3000 CEL, DISTANCE RATIO 240:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA43AF10 ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=55:1,DH=10:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 5:1
TWO-COLOUR PYROMETER PA83AF10 ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=55:1,DH=10:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 5:1
SPECTRALPYROMETER PA21AF11 ARDOCELL, MEASURING RANGE 300-2000 CEL, DISTANCE RATIO 180:1 (0,4M), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M LWL MUST BE ORDERED SEPARATELY 5 M - 7MC3900-8AA05 10 M - 7MC3900-8AA10
SPECTRALPYROMETER PA31AF11 ARDOCELL, MEASURING RANGE 550-2500 CEL, DISTANCE RATIO 190:1 (0,4M), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,78-1,06 1E-6 M LWL MUST BE ORDERED SEPARATELY 5 M - 7MC3900-8AA05 10 M - 7MC3900-8AA10
TWO-COLOUR PYROMETER PA40AF11 ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 35:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
TWO-COLOUR PYROMETER PA43AF11 ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=85:1,DH=11:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 7:1