TWO-COLOUR PYROMETER PA43AF12 ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=85:1,DH=11:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 7:1
TWO-COLOUR PYROMETER PA83AF13 ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=150:1,DH=30:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 5:1
TWO-COLOUR PYROMETER PA43AF14 ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=230:1,DH=34:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING RECTANGULAR TARGET SPOT 7:1
TWO-COLOUR PYROMETER PA40AF20 ARDOCELL, MEASURING RANGE 500-1400 CEL, DISTANCE RATIO 55:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING
SPECTRALPYROMETER PA31AF21 ARDOCELL, MEASURING RANGE 550-2500 CEL, DISTANCE RATIO 50:1, FOCAL RANGE 0,12 M..UNENDL, SPECTRAL RANGE 0,78-1,06 1E-6 M LWL MUST BE ORDERED SEPARATELY 5 M - 7MC3900-8AA05 10 M - 7MC3900-8AA10
SPECTRALPYROMETER PA21AF22 ARDOCELL, MEASURING RANGE 300-2000 CEL, DISTANCE RATIO 50:1, FOCAL RANGE 33..45 MM, SPECTRAL RANGE 1,1-1,7 1E-6 M LWL MUST BE ORDERED SEPARATELY 5 M - 7MC3900-8AA05 10 M - 7MC3900-8AA10
SPECTRALPYROMETER PA31AF22 ARDOCELL, MEASURING RANGE 550-2500 CEL, DISTANCE RATIO 50:1, FOCAL RANGE 33..45 MM, SPECTRAL RANGE 0,78-1,06 1E-6 M VERSION WITH THROUGH-THE-LENS SIGHTING AND POLARISING FILTER
SPECTRALPYROMETER PA36AF22 ARDOCELL, MEASURING RANGE 654-3000 CEL, DISTANCE RATIO 50:1, FOCAL RANGE 33..45MM, SPECTRAL RANGE 0,85-0,91 1E-6 M LWL MUST BE ORDERED SEPARATELY 5 M - 7MC3900-8AA05 10 M - 7MC3900-8AA10
TWO-COLOUR PYROMETER PA41AF22 ARDOCELL, MEASURING RANGE 800-2400 CEL, DISTANCE RATIO 50:1, FOCAL RANGE 33..45 MM, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIGHT AND POLARISING FILTER
TWO-COLOUR PYROMETER PA41AF111 ARDOCELL, MEASURING RANGE 900-3000 CEL, DISTANCE RATIO 190:1 (0,4M), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIGHT AND POLARISING FILTER
TWO-COLOUR PYROMETER PA41AF121 ARDOCELL, MEASURING RANGE 900-3000 CEL, DISTANCE RATIO 50:1, FOCAL RANGE 0,12 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIGHT
TWO-COLOUR PYROMETER PA41AF122 ARDOCELL, MEASURING RANGE 900-3000 CEL, DISTANCE RATIO 50:1, FOCAL RANGE 33..45 MM, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIGHT
TWO-COLOUR PYROMETER PA41AF211 ARDOCELL, MEASURING RANGE 700-1800 CEL, DISTANCE RATIO 110:1 (0,4M), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIGHT
TWO-COLOUR PYROMETER PA41AF221 ARDOCELL, MEASURING RANGE 700-1800 CEL, DISTANCE RATIO 36:1, FOCAL RANGE 0,12 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIGHT
TWO-COLOUR PYROMETER PA41AF222 ARDOCELL, MEASURING RANGE 700-1800 CEL, DISTANCE RATIO 36:1, FOCAL RANGE 33..45 MM, SPECTRAL RANGE 0,95/1,05 1E-6 M LWL MUST BE ORDERED SEPARATELY 5 M - 7MC3900-8AA05 10 M - 7MC3900-8AA10
SPECTRALPYROMETER PA10AF1L ARDOCELL, MEASURING RANGE 0-1000 CEL, DISTANCE RATIO 50:1 (90%), FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 8-14 1E-6 M VERSION WITH LASER SPOT LIGHT
SPECTRALPYROMETER PA20AF1L ARDOCELL, MEASURING RANGE 250-2000 CEL, DISTANCE RATIO 175:1 (90%), FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LIGHT
SPECTRALPYROMETER PA30AF1L ARDOCELL, MEASURING RANGE 500-2500 CEL, DISTANCE RATIO 210:1 (90%), FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,78-1,06 1E-6 M VERSION WITH LASER SPOT LIGHT
SPECTRALPYROMETER PA35AF1L ARDOCELL, MEASURING RANGE 600-3000 CEL, DISTANCE RATIO 210:1 (90%), FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,85-0,91 1E-6 M VERSION WITH LASER SPOT LIGHT