Control devices DOLD
Accessories (2)
I/O Modules (6)
• Optionally safe separation according to IEC/EN 61 140,
IEC/EN 60 947-1, 6 kV/2
- between coil and contacts
- between the two contacts
• As option with reduced power consumption
• Optionally for switching of low loads
• 1 or 2 changeover contacts
• for AC/DC 12 ... 240 V
• For 2-wire proximity sensors
• LED indicator
• Width 22.5 mm
• Width: 22.5 mm
• Operation as master
- Operation as slave
- Transfer rate up to 1 Mb/s
- Interface according to DS301 version 3.0
• IN 5504 locally extendable with digital and analoge in- / output
modules
• 2 digital inputs for DC 24 V
• 2 relay outputs
• LED indicators
• Standard programming software CODESYS® under Windows
according to IEC/EN 61131-3:
- Instruction set
- Ladder diagram
- Function block diagram
- Sequential function chart
- Structured text (similar to Pascal)
• 128 KB Flash memory for user program
• 128 KB RAM for user data
• 16 KB battery buffered RAM for no-voltage safe data
• Battery buffered real time clock
• Monitoring contact for RUN status of the PLC
• IL 5504: 35 mm width
IN 5504: 52.5 mm width
• Operation as master
- Operation as slave
- Transfer rate up to 1 Mb/s
- Interface according to DS301 version 3.0
• IN 5504 locally extendable with digital and analoge in- / output
modules
• 2 digital inputs for DC 24 V
• 2 relay outputs
• LED indicators
• Standard programming software CODESYS® under Windows
according to IEC/EN 61131-3:
- Instruction set
- Ladder diagram
- Function block diagram
- Sequential function chart
- Structured text (similar to Pascal)
• 128 KB Flash memory for user program
• 128 KB RAM for user data
• 16 KB battery buffered RAM for no-voltage safe data
• Battery buffered real time clock
• Monitoring contact for RUN status of the PLC
• IL 5504: 35 mm width
IN 5504: 52.5 mm width
UG 3076.15: 6 changeover contact
• Safe release voltage: the output relay is de-energized at U < 27 % UN • Width 22.5 mm
• Relay, triac or transistor output
• Protective separation according to IEC/EN 61 140,
IEC/EN 60 947-1 on devices with relay output (only at
IK 3070.01 / _0_,
IK 3070.02 /_0_,
IK 3070.11 /_0_)
• LED as operating position display
• Optionally input wiring with recovery diode or MOV
• Optionally for small switching currents
• Optionally with forcibly guided contacts
• As option with 3-position test switch:
Auto, Off, Manual/Sensor control (+ 24 V)
• As option with semiconductor output
- for high switching frequency
- input protection with varistor
• Optionally interface relay system to reduce the amount of wiring
• IK 3070: width 17.5 mm
IS 3070: width 140 mm
• Protective separation acc. to IEC/EN 61 140, IEC/EN 60 947-1:
6 kV/2, at CA/CB
• As option goldplated contacts (10 μm Au) to switch low loads
• LED indication
• Optionally with 1 NO contact, 1 NC contact, 1 C/O contact,
2 C/O contacts, 2 NO contacts
• Optionally with MOV on input to achieve higher surge immunity
• Width: 11.5 mm
• Protective separation acc. to IEC/EN 61 140, IEC/EN 60 947-1:
6 kV/2, at CA/CB
• As option goldplated contacts (10 μm Au) to switch low loads
• LED indication
• Optionally with 1 NO contact, 1 NC contact, 1 C/O contact,
2 C/O contacts, 2 NO contacts
• Optionally with MOV on input to achieve higher surge immunity
• Width: 11.5 mm
• High switching capacity of contacts
• High switching safety
• Width 45 mm
• With forcibly guided contacts according to DIN EN 50205
• With manual operation and contact position indication via control lever
• With impulse energization A1 - A2
• With reset pulse B1 - B2
• 4 NC contacts, 4 NO contacts or 4 changeover contacts
• With pluggable terminal blocks for easy exchange of devices
• Width 22.5 mm
• Manual operation possible
• Contact position indication via control lever
• max. 4 NC contacts, 4 NO contacts
• Width 45 mm
• Protective separation acc. to IEC/EN 61 140, IEC/EN 60 947-1:
6 kV/2, at CA/CB
• As option goldplated contacts (10 μm Au) to switch low loads
• LED indication
• Optionally with 1 NO contact, 1 NC contact, 1 C/O contact,
2 C/O contacts, 2 NO contacts
• Optionally with MOV on input to achieve higher surge immunity
• Width: 11.5 mm
• Input for AC/DC 24 V, AC 110 V or 230 V, as required
• 1 NO contact for AC 230 V
• LED indicator
• Width 9 mm
• Setting input A1 - A2
• Reset input A3 - A2
• Storage function
• Switch position indication
• Manual operation
• Width 22.5 mm
• Modbus RTU-interface
• 8 digital inputs for DC 24 V
• 4 Relay outputs ( 3 x 8 A, 1 x 16 A)
• LEDs for status indication
• 3 potentiometer for setting the modbus adress and baud rate
• 15 LEDs for status indication
• Width: 22.5 mm
• 2 output contacts with monostable PCB-relay OA 5668
• Version with bistable PCB-relay OB 5694
• Contact material AgNi with fine gold
• High thermal current up to Ith = 16 A with relays
OA 5682 and OB 5694
• Large temperature range: - 40 ... + 85 °C
• As option with free-wheel diode or varistor between A1/A2
• As option with AgSnO2 or AgNi with hard gold
• Width: 15.8 mm
• CANopen interface according to DS 301 version 3.0, DS 401
• 4 digital inputs for DC 24 V
• 4 relay outputs
• LED indicators
• 52.5 mm width

Control technology for all requirements
DOLD is a pioneer in the field of control technology and present the first SPS in a standard housing in the automobile and tool machine industry in 1978. Benefit from this experience. DOLD offers you a universal portfolio of safe, efficient solutions for control technology that is tailored to your needs. A comprehensive palette of field bus-capable input and output modules are available for you.