Safety technology DOLD

Показано товаров: 20 из 145
Артикул: 1324822
• According to
- Performance Level (PL) d and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Input module with enabling inputs
• for connection of 2 channel
- safety gates
- e-stop buttons
- light curtain (LC) Type 4
- change over switch
- enabling swtich
• Function combination and behaviour of enabling inputs selectable on
rotary switches
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5915) or 45 mm (BH 5915)
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324821
• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut,
autostart
- 8 E-STOP, single-channel, manual start
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
- 5 E-STOP, single-channel, + 1 E-STOP, 2-channel +
1 signal input, manual start
- As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected.
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs per function module for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324820
• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut,
autostart
- 8 E-STOP, single-channel, manual start
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
- 5 E-STOP, single-channel, + 1 E-STOP, 2-channel +
1 signal input, manual start
- As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected.
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs per function module for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324819
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module mit einer per Stufenschalter einstellbarer
Combination of the following 3 functions:
- Light curtains (LC) type 4 with manual or automatic start
- E-stop 2-channel and manual or automatic start
- Two-hand function type IIIC according to DIN/EN 574
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324818
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
· Input module for combination of 4 of the following functions to be set
via rotary switch:
- safety gate monitoring function (2 x 2 changeover contacts)
- Light curtain (LC type 4) with manual or automatic start
- Emergency stop (2-channel) with manual or automatic start
- Two-hand controls type IIIC acc. to DIN/EN 574
· Functions can be selected via rotary switches
· 8 inputs for safety sensors
· Broken wire and short circuit monitoring function with error indication
· 2 semiconductor outputs for status indication
· LEDs for status indication
· Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324817
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
· Input module for realization of
- 4 mixed 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain monitoring system (LC type 4)
· The functions are selected via rotary switch
· 8 safety inputs
· 2 semiconductor outputs for status indication
· Broken wire and short circuit monitoring function with error indication
· LEDs for status indication
· Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324816
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain (LC type 4)
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width
BG 5913.08/_0__: 22.5 mm
BH 5913.08/_0__: 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324815
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain (LC type 4)
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width
BG 5913.08/_0__: 22.5 mm
BH 5913.08/_0__: 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324814
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact
• Parallel connection of several SAFEMASTER M-systems possible
• The functions are selected via rotary switch
- 1 Emergency stop circuit, 2-channel
- 2 Emergency stop circuits, single-channel
- 1 Emergency stop circuit, 2-channel + 1 stop single channel
• Auto or manual start
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Overvoltage and undervoltage monitoring function with error indication
• Permanently monitored feedback loop to connect external contactors
• Broken wire and short circuit monitoring function with error indication
• Width: 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324813
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact
• Parallel connection of several SAFEMASTER M-systems possible
• The functions are selected via rotary switch
- 1 Emergency stop circuit, 2-channel
- 2 Emergency stop circuits, single-channel
- 1 Emergency stop circuit, 2-channel + 1 stop single channel
• Auto or manual start
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Overvoltage and undervoltage monitoring function with error indication
• Permanently monitored feedback loop to connect external contactors
• Broken wire and short circuit monitoring function with error indication
• Width: 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324812
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Category 4 to EN 954-1
• Functions selectable via rotational switches to connect max.:
- 8 E-stop circuits, single channel or
- 4 E-stop circuits, 2-channel or
- 4 light curtains or
- 2 light curtains and 1 E-stop circuit or
- 4 safety gates or
- 2 safety gates and 1 E-stop circuit or
- 4 pairs of 2-hand-buttons or Typ III A according to DIN EN 547 or
- 2 pairs of 2-hand-buttons Typ III C according to DIN EN 547
and 1 E-stop circuit
• In addition selectable:
- auto or manual reset (simulation input for gate monitor)
- continuously monitored feedback circuit to monitor external
contactors
• Cross fault detection
• Short circuit and broken wire detection
• Outputs:
- 3 NO or 2 NO and 1 NC contacts
- 2 semiconductor outputs short circuit proof and overload
protected
• Under- and overvoltage detection and signalling
• LED indication for operation (RUN), channel 1/2
• 45 mm width
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324811
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: max. 4 NO instantaneous semiconductor monitoring output
• LED indicator for operation, delay contects and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324810
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: 2 NO instantaneous contact and 2 NO contacts delayed
• 1 semiconductor output for instantaneous contacts
1 semiconductor output for delayed contacts
• LED indicator for operation, safety function, time delay and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324809
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: max. 4 NO instantaneous semiconductor monitoring output
• LED indicator for operation, delay contects and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324808
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: 2 NO contacts per safety function
• 1 semiconductor output per safety function
• LED indicator for operation, safety function 1, 2 and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324883
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Machine directive 2006/42/EG
• DIN EN 574: Safety of machinery - Two-hand control devices -
• DIN EN 300 220: Electromagnetic compatibility and Radio spectrum Matters
(ERM) - Short Range Devices (SRD) - Radio equipment to be used in
the 25 MHz to 1000 MHz frequency range with power levels ranging up
to 500 mW
• Depending on the operating mode, to connect:
- E-stop push-button (2-channel), safety gate, LC (non-contact safety
system, for example light curtain) of the type 4 in accordance with
EN 61 496 or the two-hand type IIIA in accordance with DIN EN 574.
- 1 start button
- Changeover switch (2-channel) to indicate radio use in the
Safety operation with optional radio control operating mode
• For two-way communication via radio:
- Safety shut-down commands
- Signals from 8 non-safety-relevant DC 24 V inputs at 8 non-safetyrelevant
DC 24 V semiconductor outputs
• Broken wire and short circuit monitoring function with error indication
• Semiconductor output to indicate poor or no radio control
• 2 semiconductor outputs for status indication
• LEDs to indicate
- status of module
- status of all inputs and outputs
- the radio transmission and its quality
• Width: 45 mm
В корзину

Товар в корзине.

Перейти в корзину
В корзину

Товар в корзине.

Перейти в корзину
В корзину

Товар в корзине.

Перейти в корзину
В корзину

Товар в корзине.

Перейти в корзину

SAFEMASTER - Innovation solutions for every function

Safety technology is an essential product group of the business area of switching devices at DOLD. What began decades ago with the development of a two-hand switch relay has been decisively continued in the last 20 years and expanded into a universal device programme. Today, safety switching devices from DOLD monitor various safety functions such as emergency stop, two-hand switching, safety mat, safety door, light barrier and more.