Safe switching and monitoring Schmersal
Key transfer system (53)
Foot switch (6)
Enabling device (3)
Control panels (46)
Solenoid interlock (227)
Position switch (824)
Safety sensors (235)
• Simple mounting without additional angle
• RFID-technology for needs-based protection against tampering
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 1 x connector plug M8
• Frontal and lateral actuation enabled
• Max. 31 sensors can be wired in series.
• Simple mounting without additional angle
• RFID-technology for needs-based protection against tampering
• Universal coding with RFID technology
• 1 x connector plug M8
• Frontal and lateral actuation enabled
• Max. 31 sensors can be wired in series.
• Simple mounting without additional angle
• RFID-technology for needs-based protection against tampering
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 1 x connector plug M8
• Frontal and lateral actuation enabled
• Max. 31 sensors can be wired in series.
• Simple mounting without additional angle
• RFID-technology for needs-based protection against tampering
• Repeated individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 1 x connector plug M8
• Frontal and lateral actuation enabled
• Max. 31 sensors can be wired in series.
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 2 Connector M12, 8- and 5-poles
• Guard locking monitored
• 2 Diagnostic outputs
• manual release
• Electric manual release with auxiliary voltage
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Repeated individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 2 Connector M12, 8- and 5-poles
• Guard locking monitored
• 2 Diagnostic outputs
• manual release
• Electric manual release with auxiliary voltage
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• Connector M12, 8-pole
• Guard locking monitored
• 1 Diagnostic output
• manual release
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Repeated individual coding with RFID technology
• Coding level "High" according to ISO 14119
• Connector M12, 8-pole
• Guard locking monitored
• 1 Diagnostic output
• manual release
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 2 Connector M12, 8- and 5-poles
• Guard locking monitored
• 2 Diagnostic outputs
• Emergency exit
• Electric manual release with auxiliary voltage
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Repeated individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 2 Connector M12, 8- and 5-poles
• Guard locking monitored
• 2 Diagnostic outputs
• Emergency exit
• Electric manual release with auxiliary voltage
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• Connector M12, 8-pole
• Guard locking monitored
• 1 Diagnostic output
• Emergency exit
• Clamping force 10.000 N
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Repeated individual coding with RFID technology
• Coding level "High" according to ISO 14119
• Connector M12, 8-pole
• Guard locking monitored
• 1 Diagnostic output
• Emergency exit
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool
• User-friendly parameter setting, no tools required
• Reliable safety concept in case of interferences (EMC, welding sparks)
• Process safety with highest availability
• Integrated set-up tool