Safe signal processing Schmersal
Input expander (12)
Output expanders (3)
• 2 safety contacts, STOP 0
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
• 2 Signalling outputs
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
• 2 Signalling outputs
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Safety mats
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Safety mats
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Two-hand control panels and Safety mats
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Two-hand control panels and Safety mats
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Fit for signal evaluation of outputs of safety magnetic switches
• 5 safety contacts, STOP 0
• 4 Signalling outputs
• 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• Level 1: Reset with edge detection, Level 2: / Opener (NC) Opener (NC)
• 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Opener (NC) Normally open contact (NO)
• Two-functions safety monitoring module (double evaluation)
• 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• Two-functions safety monitoring module (double evaluation)
• 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Opener (NC) Opener (NC)
• 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• Level 1: Reset with edge detection, Level 2: / Opener (NC) Normally open contact (NO)
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0;
2 safety contacts, STOP 1 (adjustable 1 ... 30 s)
• 4 Signalling outputs
• Optional: Short-circuit recognition, Manual reset with edge detection in fail-safe circuit, Automatic reset function
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0; 2, safety contacts STOP 1
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• 2 + 6 Signalling outputs
• Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit recognition, Level 2: / Opener (NC) Normally open contact (NO)

Свяжитесь с нами
Если вы не нашли нужной информации на сайте или у вас остались вопросы по товарам, оставьте заявку на бесплатную консультацию, и мы вам перезвоним












Ответ от производителя может занять до 5 дней и более.