Safe signal processing Schmersal
Input expander (12)
Output expanders (3)
• Fit for signal evaluation of outputs of safety magnetic switches
• 2 safety contacts, STOP 0
• 6 Signalling outputs
Multi-evaluation of up to 6 safety guards
• 2 safety contacts, STOP 0
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 2 safety contacts, STOP 0
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs
• Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: Opener (NC) / Opener (NC)
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs
• Level 1: Reset with edge detection, Level 2 Opener (NC) / Opener (NC)
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs
• Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Opener (NC) Normally open contact (NO)
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs
• Level 1: Reset with edge detection, Short-circuit recognition, Level 2 Opener (NC): Opener (NC) /
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs
• Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit recognition, Level 2: Opener (NC) / Normally open contact (NO)
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs
• Level 1: Reset with edge detection, Level 2: / Opener (NC) Normally open contact (NO)
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Drop-out delay can be set between 0,4 to 1,5 s
• 3 safety contacts, STOP 1
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 4 safety contacts, STOP 0
• 2 Signalling outputs
• 4 safety contacts, STOP 0
• 1 Signalling output
• 4 safety contacts, STOP 0
• 1 Signalling output
•
• Start button / Auto-start
• 2 Safety outputs
• 4 Signalling outputs