Measuring and monitoring relays DOLD

Показано товаров: 20 из 180
Артикул: 1324918
• According to IEC/EN 60 255, VDE 0435, DIN VDE 0660 part 302
(pr EN 60 947-8) and part 303
• Monitoring of phase failure
- Undervoltage 3-phase 3 or 4 wire
- Phase failure
- Phase sequence
- Loss of neutral
- Phase asymmetry
• Without auxiliary supply
• De-energized on trip
• LED indication
- Supply voltage
- Phase failure
• 1 or 2 changeover contacts
• Depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325022
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325020
• According to IEC/EN 60 255-1, IEC/EN 60 947-1
• to: monitor DC and AC
• BA 9053 with measuring ranges from 2 mA to 25 A
• BA 9053 optionally with 3 measuring ranges 0.1 up to 25 A
• MK 9053N with measuring ranges from 2 mA up to 10 A
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between auxiliary circuit - measuring ciruit
• Auxiliary supply AC/DC; BA 9053 with AC
• BA 9053 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9053 optionally with safe separation to IEC/EN 61140
• MK 9053N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9053N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9053: 45 mm
Width MK 9053N: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325021
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324925
• According to IEC/EN 60 255-1
• To monitor fuses in single and 3-phase AC voltage systems
with neutral
• Adjustable operating voltages: 400 V / 230 V and
230 V / 130 V and 110 V / 64V
• Undervoltage detection below 0.8 x UB
• Fast detection of a blown fuse
• No separate auxiliary necessary
• Output: 1 changeover contact
• De-energized on trip
• Adjustable switching delay
• Width:
-- RL 9075: 35 mm
-- RN 9075: 52.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324926
• According to IEC/EN 60 255-1
• To monitor fuses in single and 3-phase AC voltage systems
with neutral
• Adjustable operating voltages: 400 V / 230 V and
230 V / 130 V and 110 V / 64V
• Undervoltage detection below 0.8 x UB
• Fast detection of a blown fuse
• No separate auxiliary necessary
• Output: 1 changeover contact
• De-energized on trip
• Adjustable switching delay
• Width:
-- RL 9075: 35 mm
-- RN 9075: 52.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324928
• According to IEC/EN 60 255
• Detection of
- undervoltage 1 up to 3-phase, 0.85 x UN
- phase failure
• Without auxiliary voltage
• De-energized on trip
• LED indicator for L1, L2, L3 with test key to simulate failure
• 2 changeover contacts
• Width 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324927
• According to IEC/EN 60 255-1
• Monitors continuously breaker trip circuits
• 2 changeover contacts
• Galvanic separated electronic
• De-energized on trip
• With pluggable terminal blocks for easy exchange of devices
• Terminal blocks coded
• Width 22,5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324932
• According to IEC/EN 60 255, DIN VDE 0435-303
• Detection of phase failure in 3-phase systems
• Single phase connection possible
• Closed circuit operation
• Independent of phase sequence
• LED indicator for each phase
• Output 1 changeover contact
• Devices available in 2 enclosure versions:
- I- and R-versions, e.g. IK 9169 with depth 61 mm or RK 9169
with depth 71 mm with terminls at the bottom for installation
systems and industrial distribution systems according to DIN 43880
- S-version, e.g. SK 9169: depth 100 mm, with terminals at
the top for cabinets with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324931
• According to IEC/EN 60255-1
• Detection of under-/overvoltage and phase sequence in 3-phase
voltage systems
• Without separate auxiliary voltage
• LED-Indication for operation voltage and contact position
• De-energized on trip
• With fixed response value for undervoltage
• With fixed response value for overvoltage
• Width: 17,5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324930
• According to IEC/EN 60 255, DIN VDE 0435-303
• Indication of phase failure in 3-phase systems
• Single phase connection possible
• Independent of phase sequence
• LED indicator for each phase
• Devices available in 2 enclosure versions:
IK 9168: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9168: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324919
• According to IEC/EN 60 255, DIN VDE 0435-303
• Identification of overvoltage, undervoltage and phase failure
• With asymmetry identification as an option
• Mains fault diagnostics with a number of LEDs
• Setting values for overvoltage and undervoltage can be set
separately
• Large Setting Ranges 0.9 ... 1.3 UN and 0.7 ... 1.1 UN
• Time delay variable between 0.1 ... 20 s
• Closed circuit operation
• No auxiliary voltage
• Independant of phase sequence
• As option with phase sequence detection
• Single-phase connection possible
• Optionally for 3P3W Systems
• 2 changeover contacts, at IP/SP 9077 2 x 2 changeover contacts
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IL 9077, SL 9077: width 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324920
• According to IEC/EN 60 255, DIN VDE 0435-303
• Identification of overvoltage, undervoltage and phase failure
• With asymmetry identification as an option
• Mains fault diagnostics with a number of LEDs
• Setting values for overvoltage and undervoltage can be set
separately
• Large Setting Ranges 0.9 ... 1.3 UN and 0.7 ... 1.1 UN
• Time delay variable between 0.1 ... 20 s
• Closed circuit operation
• No auxiliary voltage
• Independant of phase sequence
• As option with phase sequence detection
• Single-phase connection possible
• Optionally for 3P3W Systems
• 2 changeover contacts, at IP/SP 9077 2 x 2 changeover contacts
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IP 9077, SP 9077: width 70 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324929
• According to IEC/EN 60 255, DIN VDE 0435-303
• Indication of phase failure in 3-phase systems
• Single phase connection possible
• Independent of phase sequence
• LED indicator for each phase
• Devices available in 2 enclosure versions:
IK 9168: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9168: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324933
• According to IEC/EN 60 255, DIN VDE 0435-303
• Detection of phase failure in 3-phase systems
• Single phase connection possible
• Closed circuit operation
• Independent of phase sequence
• LED indicator for each phase
• Output 1 changeover contact
• Devices available in 2 enclosure versions:
- I- and R-versions, e.g. IK 9169 with depth 61 mm or RK 9169
with depth 71 mm with terminls at the bottom for installation
systems and industrial distribution systems according to DIN 43880
- S-version, e.g. SK 9169: depth 100 mm, with terminals at
the top for cabinets with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325004
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of undervoltage
• Without auxiliary supply
• Optionally fixed or settable response value
• N.C. circuit operation
• Optionally with off-delay t1
• Optionally with on-delay t2
• LED indicator for state of output relay
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9173: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9173: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325003
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of undervoltage in 3-phase system
• Also for single phase
• Without auxiliary supply
• Optionally for 3p3w systems
• LED indicator for state of output relay
• Independent of phase sequence
• 1 or 2 changeover contacts
• Optionally fixed or settable response value
• As option with phase sequence detection
• Optionally with or without N
• Optionally with off-delay t1
• Opionally with on delay t2
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width:
IK 9171, SK 9171: 17.5 mm
IL 9171, SL 9171: 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325002
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of undervoltage in 3-phase system
• Also for single phase
• Without auxiliary supply
• Optionally for 3p3w systems
• LED indicator for state of output relay
• Independent of phase sequence
• 1 or 2 changeover contacts
• Optionally fixed or settable response value
• As option with phase sequence detection
• Optionally with or without N
• Optionally with off-delay t1
• Opionally with on delay t2
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width:
IK 9171, SK 9171: 17.5 mm
IL 9171, SL 9171: 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325001
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of undervoltage in 3-phase system
• Also for single phase
• Without auxiliary supply
• Optionally for 3p3w systems
• LED indicator for state of output relay
• Independent of phase sequence
• 1 or 2 changeover contacts
• Optionally fixed or settable response value
• As option with phase sequence detection
• Optionally with or without N
• Optionally with off-delay t1
• Opionally with on delay t2
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width:
IK 9171, SK 9171: 17.5 mm
IL 9171, SL 9171: 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325000
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of undervoltage in 3-phase system
• Also for single phase
• Without auxiliary supply
• Optionally for 3p3w systems
• LED indicator for state of output relay
• Independent of phase sequence
• 1 or 2 changeover contacts
• Optionally fixed or settable response value
• As option with phase sequence detection
• Optionally with or without N
• Optionally with off-delay t1
• Opionally with on delay t2
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width:
IK 9171, SK 9171: 17.5 mm
IL 9171, SL 9171: 35 mm
В корзину

Товар в корзине.

Перейти в корзину

Maximum functionality for your application

DOLD offers custom solutions for the monitoring of electrical variables such as current, voltage, power, resistance, et cetera. The measuring relays report error conditions and thus offer increased protection even for complex systems as well a ensure an optimal production process. LEDs on the front of the device provide you with optimal information about the current condition. We can provide you with both mono-functional and multifunctional relays with which you can realise your solutions with minimal costs or maximum flexibility and functionality.