Measuring and monitoring relays DOLD
• Recognizes fuse failures in three-phase mains up to 3 AC 690 V
• Can be used for all types and sizes of fuses
• Independent of phase sequence
• Signals even if loads are switched off
• No malfunction on
- asymmetrical mains
- mains with harmonic waves
- motors producing feedback
• Shorter response time than with motor circuit-breakers
• Green LED for intact fuses
• Red LED for fuse failure
• As option: open/closed circuit operation in the case
of IP 9075 programmable via X4-X5 or X3-X4
• As option: with manual reset function and remote reset,
programmable via X1-X2
• As option: 1 NO contact or 2 changeover contacts
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IL 9075, SL 9075: width 35 mm
IP 9075, SP 9075: width 70 mm
• Detection of over- or underfrequency of alternating voltage
(adjustable function)
• Fast reaction time by measuring duration of cycle of input frequency
• Universal measuring input for AC-voltages of 15 ... 280 V
as well as 30 ... 550 V
• As option with measuring input for inverters
• 4 ranges adjustable response value 1,5 ... 200 Hz or 5 ... 600 Hz
• Adjustable hysteresis
• Adjustable start up time delay 0 ... 50 s at function underfrequency
• Adjustable monitoring time for missing input signal at function
overfrequency
• Response delay programmable via terminals 0 ... 100 s
• Alarm storing or auto-reset programmable via terminals
• Galvanic separation between measuring input, auxiliary voltage
and output contacts
• MH 9837 available with wide input range for auxiliary supply
(AC/DC 24 ... 60 V or AC/DC 110 ... 230 V)
• 2 changeover contacts, closed circuit operation
• Open circuit operation on request
• LED indication for auxiliary voltage, measuring voltage and
alarm status
• MH 9837.12/008: with galvanic separated analogue output (current/
voltage) and 11 step LED chain for the actual frequency
• Device available with 2 response values and seperately controlled
outputrelays for under- and overfrequency see MK 9837N/500
• 2 possible compact designs:
MK 9837N: Width 22,5 mm
MH 9837: Width 45 mm
• To monitor fuses in single and 3-phase AC voltage systems
• Undervoltage detection below 0.7 x UN
• No separate auxiliary necessary
• 2 changeover contacts
• 2 nominal voltages adjustable:
3/N AC 240 V / 140 V or 3/N AC400 V / 230 V or
fixed nominal voltage: 3/N AC 110 V / 64 V
• Adjustable operate delay
• Energized on trip
• Automatic adjustment to 50 Hz and 60 Hz mains frequency
• Width 22.5 mm
• Recognizes fuse failures in three-phase mains up to 3 AC 690 V
• Can be used for all types and sizes of fuses
• Independent of phase sequence
• Signals even if loads are switched off
• No malfunction on
- asymmetrical mains
- mains with harmonic waves
- motors producing feedback
• Shorter response time than with motor circuit-breakers
• Green LED for intact fuses
• Red LED for fuse failure
• As option: open/closed circuit operation in the case
of IP 9075 programmable via X4-X5 or X3-X4
• As option: with manual reset function and remote reset,
programmable via X1-X2
• As option: 1 NO contact or 2 changeover contacts
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IL 9075, SL 9075: width 35 mm
IP 9075, SP 9075: width 70 mm
• Detection of under- or overfrequency
• Adjustable response value
• Optionally 1 or 2 changeover contacts
• Width 45 mm
• Detection of over- or underfrequency of alternating voltage
(adjustable function)
• Fast reaction time by measuring duration of cycle of input frequency
• Universal measuring input for AC-voltages of 15 ... 280 V
as well as 30 ... 550 V
• As option with measuring input for inverters
• 4 ranges adjustable response value 1,5 ... 200 Hz or 5 ... 600 Hz
• Adjustable hysteresis
• Adjustable start up time delay 0 ... 50 s at function underfrequency
• Adjustable monitoring time for missing input signal at function
overfrequency
• Response delay programmable via terminals 0 ... 100 s
• Alarm storing or auto-reset programmable via terminals
• Galvanic separation between measuring input, auxiliary voltage
and output contacts
• MH 9837 available with wide input range for auxiliary supply
(AC/DC 24 ... 60 V or AC/DC 110 ... 230 V)
• 2 changeover contacts, closed circuit operation
• Open circuit operation on request
• LED indication for auxiliary voltage, measuring voltage and
alarm status
• MH 9837.12/008: with galvanic separated analogue output (current/
voltage) and 11 step LED chain for the actual frequency
• Device available with 2 response values and seperately controlled
outputrelays for under- and overfrequency see MK 9837N/500
• 2 possible compact designs:
MK 9837N: Width 22,5 mm
MH 9837: Width 45 mm
• Detection of
-- missing neutral in the system
-- broken neutral on IL/SL 9069
-- neutral exchanged against phase
• Detection of phase failure also with disconnected load
• For 3-phase systems
• De-energized on trip
• LED indicator for operation/state of output contacts
• Single phase connection possible
• Without auxiliary voltage
• 2 cangeover contacts
• Optionally with adjustable asymmetry detection and on delay
• Devices available in 2 enclosure version:
IL 9069: depth 59 mm with terminals at the bottom for
installations systems and industrial distribution
systems according to DIN 43 880
SL 9069: depth 98 mm with terminals at the top for
cabinets with mounting plate and cable duct
• Width 35 mm
• Monitoring of overfrequency and underfrequency (selectable)
in A.C. power systems
• Without auxiliary voltage
• Selection of frequency range for 50 or 60 Hz systems
• Adjustable response value
• Adjustable hysteresis
• De-energized on trip (output relay not activated in case of error)
• LED indicators for measuring voltage and contact position
• 1 changeover contact
• As option energized on trip (output relay activated in case of error)
• Devices available in 2 enclosure versions:
IK 9143: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9143: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• 17.5 mm width
• Detection of
-- missing neutral in the system
-- broken neutral on IL/SL 9069
-- neutral exchanged against phase
• Detection of phase failure also with disconnected load
• For 3-phase systems
• De-energized on trip
• LED indicator for operation/state of output contacts
• Single phase connection possible
• Without auxiliary voltage
• 2 cangeover contacts
• Optionally with adjustable asymmetry detection and on delay
• Devices available in 2 enclosure version:
IL 9069: depth 59 mm with terminals at the bottom for
installations systems and industrial distribution
systems according to DIN 43 880
SL 9069: depth 98 mm with terminals at the top for
cabinets with mounting plate and cable duct
• Width 35 mm
• Overfrequency or underfrequency monitoring of AC voltages
• Adjustable response value fmin. or fmax 5 ... 200 Hz or 15 ... 600 Hz
• Adjustable hysteresis
• Large voltage range of the measuring input (nominal voltage
AC 24 ... 440 V)
• De-energized on trip
• LED indication for auxiliary voltage, measuring voltage and contact
position
• 1 changeover contact
• As option for frequency inverters with a range of 1 … 300 Hz
• 2 changeover contacts available on request
• As option adjustable start-up delay available
• Energized on trip function available on request
• Devices available in 2 enclosure versions:
IL 9837: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9837: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• 35 mm width
• Monitoring of overfrequency and underfrequency (selectable)
in A.C. power systems
• Without auxiliary voltage
• Selection of frequency range for 50 or 60 Hz systems
• Adjustable response value
• Adjustable hysteresis
• De-energized on trip (output relay not activated in case of error)
• LED indicators for measuring voltage and contact position
• 1 changeover contact
• As option energized on trip (output relay activated in case of error)
• Devices available in 2 enclosure versions:
IK 9143: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9143: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• 17.5 mm width
• Overfrequency or underfrequency monitoring of AC voltages
• Adjustable response value fmin. or fmax 5 ... 200 Hz or 15 ... 600 Hz
• Adjustable hysteresis
• Large voltage range of the measuring input (nominal voltage
AC 24 ... 440 V)
• De-energized on trip
• LED indication for auxiliary voltage, measuring voltage and contact
position
• 1 changeover contact
• As option for frequency inverters with a range of 1 … 300 Hz
• 2 changeover contacts available on request
• As option adjustable start-up delay available
• Energized on trip function available on request
• Devices available in 2 enclosure versions:
IL 9837: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9837: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• 35 mm width
and part 303
• 1 input for PTC-resistors or bimetal contacts
• Broken wire detection in sensor circuit
• Optionally with no voltage reclosing interlock
• Closed circuit operation
• 1 or 2 changeover contacts
• Width 45 mm
• For nominal voltage from 3 AC 230 V to 500 V
• Detection of
- voltage asymmetry
- wrong phase sequence
- phase failure
• Detection of feedback voltage
• BA 9042 optionally with adjustable time delay
• Closed circuit operation
• BA 9042 LED indicators for operation and state of contacts
• Width 45 mm
• For nominal voltage from 3 AC 230 V to 500 V
• Detection of
- voltage asymmetry
- wrong phase sequence
- phase failure
• Detection of feedback voltage
• BA 9042 optionally with adjustable time delay
• Closed circuit operation
• BA 9042 LED indicators for operation and state of contacts
• Width 45 mm
• Recognition of
- voltage asymmetry
- phase failure
- voltage feedback
- optionally with phase sequence recognition
• Optionally with adjustable response delay
• 2 LED displays for power supply and state of contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• BA 9040: width 45 mm
MK 9040N: width 22.5 mm
• Recognition of
- voltage asymmetry
- phase failure
- voltage feedback
- optionally with phase sequence recognition
• Optionally with adjustable response delay
• 2 LED displays for power supply and state of contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• BA 9040: width 45 mm
MK 9040N: width 22.5 mm
• Monitoring of
- Under- and overvoltage
- Asymmetry
- Phase failure
- Phase sequence
• Adjustable time delay between 0.1 ... 5 s
• One LED in each case for:
- Auxiliary voltage A1/A2
-Overvoltage Umax.
- Undervoltage Umin.
- Asymmetry / Phase sequence / Power failure
- Contact position
• Closed circuit operation
• 2 changeover contacts
• As option available with open circuit operation
• Width 45 mm
• to: monitor DC and AC
• BA 9053 with measuring ranges from 2 mA to 25 A
• BA 9053 optionally with 3 measuring ranges 0.1 up to 25 A
• MK 9053N with measuring ranges from 2 mA up to 10 A
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between auxiliary circuit - measuring ciruit
• Auxiliary supply AC/DC; BA 9053 with AC
• BA 9053 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9053 optionally with safe separation to IEC/EN 61140
• MK 9053N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9053N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9053: 45 mm
Width MK 9053N: 22.5 mm
Maximum functionality for your application
DOLD offers custom solutions for the monitoring of electrical variables such as current, voltage, power, resistance, et cetera. The measuring relays report error conditions and thus offer increased protection even for complex systems as well a ensure an optimal production process. LEDs on the front of the device provide you with optimal information about the current condition. We can provide you with both mono-functional and multifunctional relays with which you can realise your solutions with minimal costs or maximum flexibility and functionality.