Measuring and monitoring relays DOLD
• For DC monitoring
• Detection of
- Overvoltage
- Untervoltage
- Voltage range excess in single-phase AC voltage systems
• No separate auxiliary necessary
• Output: 1 changeover contact
• De-energized on trip
• Adjustable switching voltage
• Adjustable hysteresis for reset
• Adjustable switching delay
• Fast fault detection
• Width: 35 mm
• For DC monitoring
• Detection of
- Overvoltage
- Untervoltage
- Voltage range excess in single-phase AC voltage systems
• No separate auxiliary necessary
• Output: 1 changeover contact
• De-energized on trip
• Adjustable switching voltage
• Adjustable hysteresis for reset
• Adjustable switching delay
• Fast fault detection
• Width: 35 mm
• Effective power measuring
• For single and 3-phases
• Adjustable response value 2 ... 20 % reverse power
• Hysteresis 12.5 %
• Rated current BH 9140: 5 A or 40 A
Rated current RP 9140: 5 A
• Adjustable on delay
• Open circuit operation
• LED indication for voltage supply and contact position
• 2 changeover contacts
• As option closed circuit operation
• Width:
BH 9140: 45 mm
RP 9140: 70 mm
• Effective power measuring
• For single and 3-phases
• Adjustable response value 2 ... 20 % reverse power
• Hysteresis 12.5 %
• Rated current BH 9140: 5 A or 40 A
Rated current RP 9140: 5 A
• Adjustable on delay
• Open circuit operation
• LED indication for voltage supply and contact position
• 2 changeover contacts
• As option closed circuit operation
• Width:
BH 9140: 45 mm
RP 9140: 70 mm
• Detection of underload (cos ϕ)
• Without auxiliary supply
• Current up to 8 A
Motors up to 5 A nominal current can be connected directly
• Higher currents via current transformer
• SL 9065CT with integrated current transformer for currents up to 100 A
• Adjustable response value
• Automatic reset (Alarm auto reset)
• Adjustable operate delay up to 100 s
• De-energized on trip
• For single and 3-phase loads e.g. motors
• Independent of phase sequence
• 1 changeover contact
• LED indicator voltage supply and alarm
• Devices available in 2 enclosure versions: IK 9065: depth 58 mm,
with terminals at the bottom for installation systems and industrial
distribution systems according to DIN 43 880
SK 9065, SL 9065CT: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9065, SK 9065 width 17.5 mm
SL 9065CT width 35 mm
IK/SK 9065/100: as IK/SK 9065 but:
• programmable for
- automatic reset or manual reset (latched alarm)
- energized or de-energized on trip
• with reset button
• remote reset
• Detection of underload (cos ϕ)
• Without auxiliary supply
• Current up to 8 A
Motors up to 5 A nominal current can be connected directly
• Higher currents via current transformer
• SL 9065CT with integrated current transformer for currents up to 100 A
• Adjustable response value
• Automatic reset (Alarm auto reset)
• Adjustable operate delay up to 100 s
• De-energized on trip
• For single and 3-phase loads e.g. motors
• Independent of phase sequence
• 1 changeover contact
• LED indicator voltage supply and alarm
• Devices available in 2 enclosure versions: IK 9065: depth 58 mm,
with terminals at the bottom for installation systems and industrial
distribution systems according to DIN 43 880
SK 9065, SL 9065CT: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9065, SK 9065 width 17.5 mm
SL 9065CT width 35 mm
IK/SK 9065/100: as IK/SK 9065 but:
• programmable for
- automatic reset or manual reset (latched alarm)
- energized or de-energized on trip
• with reset button
• remote reset
• Detection of underload (cos ϕ)
• Without auxiliary supply
• Current up to 8 A
Motors up to 5 A nominal current can be connected directly
• Higher currents via current transformer
• SL 9065CT with integrated current transformer for currents up to 100 A
• Adjustable response value
• Automatic reset (Alarm auto reset)
• Adjustable operate delay up to 100 s
• De-energized on trip
• For single and 3-phase loads e.g. motors
• Independent of phase sequence
• 1 changeover contact
• LED indicator voltage supply and alarm
• Devices available in 2 enclosure versions: IK 9065: depth 58 mm,
with terminals at the bottom for installation systems and industrial
distribution systems according to DIN 43 880
SK 9065, SL 9065CT: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9065, SK 9065 width 17.5 mm
SL 9065CT width 35 mm
IK/SK 9065/100: as IK/SK 9065 but:
• programmable for
- automatic reset or manual reset (latched alarm)
- energized or de-energized on trip
• with reset button
• remote reset
• Detection of underload (cos ϕ)
• Current ranges up to 10 A
• Adjustable response value
• Programmable functions:
- automatic or manual reset
- closed or open circuit operation
• Manual remote reset
• Adjustable operate delay up to 100 s
• For single and 3-phase AC-systems without neutral
• Independent of phase sequence
• Also for 400 Hz systems
• MK 9065.11 can be used for motors with frequency converters
2 ... 200 Hz)
• Optionally with sealable cover
• Green indicator LED for operational mode
• Red indicator LED for underload monitoring
• Width 22.5 mm
• Detection of underload (cos ϕ)
• Current ranges up to 10 A, for higher values a CT must be used
• Adjustable response value
• Programmable functions:
- alarm when I = 0
- automatic or manual reset
- closed or open circuit operation
• Manual remote reset
• Adjustable operate delay
• Independent of phase sequence
• Also for 400 Hz systems
• Optionally for motors with frequency converters (10 ... 100 Hz)
(see notes)
• Width 45 mm
• As load depending output signals are available
- 0 ... 20 mA and 0 ... 10 V or
- 4 ... 20 mA and 2 ... 10 V
• Measures effective load
• Adjustment of P1 and P2 on absolute scale
• For motors up to 22 kW / 400 V bzw. 37 kW / 690 V
• Adjustable start up delay ta
• Up to 40 A without external current transformer
• As option for single phase loads
• LED indicators
• Width 45 mm
• Identification of
- Underload P1 and Overload P2
- Overload P1 (prewarning) and Overload P2
programmable
• Adjustment of P1 and P2 on absolute scale
• For motors up to 22 kW / 400 V; 37 kW / 600 V
• Measurement: effective power
• Large current range because of automatic range selection
• 1 changeover contact for P1 and 1 changeover contact for P2
• Adjustable start-up delay ta
• Adjustable switching delay tv
• With automatic or manual reset, programmable
• Test / Reset button for easy setup
• Up to 40 A without external current transformer
• De-energized or energized on fault, programmable
• Also for single-phase operation
• LED indicators
• Width 45 mm
• Active power measuring
• Relay output
MK 9397N: 1 changeover contact
MH 9397: 1 changeover contact each for overload and prewarning
• On delay
• Closed circuit operation
• As option open circuit operation
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• MK 9397N: Width 22,5 mm
MH 9397: Width 45 mm
• Active power measuring
• Relay output
MK 9397N: 1 changeover contact
MH 9397: 1 changeover contact each for overload and prewarning
• On delay
• Closed circuit operation
• As option open circuit operation
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• MK 9397N: Width 22,5 mm
MH 9397: Width 45 mm
• Monitoring of 50 - and 60 Hz-current supply on
over- and underfrequency
• Monitoring of local generator sets and voltage supplies
• For precise frequency measuring with fast response time
• High disturbance immunity
• Separately adjustable trip points and separate outputs for overand
underfrequency (1 or 2 c/o each)
• MK 9143N / MH 9143:
- Trip points adjustable precisely and reproducible on 10 step
rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to
50 or 60 Hz
- Nominal frequency 50 or 60 Hz selectable
- Fixed hysteresis optimised for trip point
- Time delay for over and underfrequency each adjustable
from 0 to 20 s
- As option one common output for under and overfrequency
“Window”-mode (MK 9143N/400 / MH 9143/400)
• MH 9143.38/008: with galvanic separated analogue output (current/
voltage) and 11 step LED chain for the actual frequency
• MK 9143N/600 / MH 9143/600:
- Variable alarm value in the range of 45 to 65 Hz
- Hysteresis adjustable for under- and overfrequency separately
adjustable 0 …20%
- Common output for under and overfrequency “Window”-mode
can be selected
• Start up delay 0…30 s selectable
• Manual or auto reset selectable
• Output relay energized or de-energized on trip selectable for
overfrequency
• Output relay de-energized on trip for underfrequency
• Universal frequency measuring input for AC 40 … 550V
• Several options for auxiliary supply
• As option without aux. supply for voltage range AC 18 … 70 V or
70 … 275V
• LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
• 2 possible contact arrangements
MK 9143N and MK 9143N/600: 2 x 1 C/O contacts, width 22,5 mm
MH 9143 and MH 9143/600: 2 x 2 C/O contacts, width 45 mm
• Monitoring of AC voltage for under and overfrequency,
can be used also for pre-warning
• Separate relay outputs for over- or underfrequency
(1 or 2 changeover contacts each)
• Alternative usage for monitoring of a frequency window
• Separate adjustment of response value for over- or underfrequency
at 4 ranges each, 1.5 ... 200 Hz or 5 ... 600 Hz
• Second response value for prewarning possible
• Fast reaction time by measuring duration of cycle of input frequency
• Universal measuring input for AC-voltages of 15 ... 280 V
as well as 30 ... 550 V
• As option with measuring input for inverters
• Programmable hysteresis of response value: 2 ... 10 %
• Start up time delay programmable via terminals from
0 ... 50 s e.g. continuously
• Manual or auto-reset programmable via terminals
• Galvanic separation between measuring input, auxiliary voltage
and output contacts
• MH 9837/508: with galvanic separated analogue output (current/
voltage) and 11 step LED chain for the actual frequency
• MH 9837/5_0: with wide input range for auxiliary voltage available
(AC/DC 24 ... 60 V or AC/DC 110 ... 230 V)
• Closed circuit operation (de-energized on trip)
• LED indication for auxiliary voltage, measuring voltage and
alarm status
• Device available with 2 contacts
MK 9837N/5_0: 2 x 1 changeover contact
MH 9837/5_0: 2 x 2 changeover contacts or
wide auxiliary voltage range
• 2 possible compact designs:
MK 9837N/5_0: Width 22,5 mm
MH 9837/5_0: Width 45 mm
• Surveillance en sous et surfréquence de réseaux 50/60Hz
• Surveillance de groupes et générateurs électriques
• Mesure de fréquence précise et rapide
• Entrée de mesure fortement protégée
• 2 seuils d’alarme séparés pour sous et surfréquence avec des
sorties relais séparées. (1 ou 2 inverseurs pour chaque relais)
• MK 9143N / MH 9143:
- Seuils d’alarme réglables précisément au travers d’un
commutateur 10 positions pour des plages de + 0,1 à + 5 Hz
de la fréquence de référence
- Fréquance de référence commutable de 50 à 60 Hz
- Hysterese fixe adaptée au seuil de réglage
- Temporisations d’alarme pour la sous et la surfréquence
réglables séparément de 0-20s.
- Sur demande, avec relais de sortie rágissant en mode“
Windows“ (à l’intérieur d’une fenêtre de fréquence)
(MK 9143N/400 / MH 9143/400)
• MH 9143.38/008: avec sortie analogique séparée galvaniquement
ainsi qu'une barre de visualisation à 11 LED pour l'indication de la
valeur actuelle de l'isolement
• MK 9143N/600 / MH 9143/600:
- Seuil d’alarme réglable dans une plage de 45-65Hz
- Hystérèse réglable séparément pour le seuil de sous et
surfréquence de 0,5-20%
- Mode de fonctionnement Window du relais de sortie
programmable (fenêtre de fréquence)
• Temporisation de démarrage configurable sur bornier dans la
plage de 0-30s
• Fonction Mémorisation ou hystérése de l’alarme configurable sur bornier
• Relais de sortie pour la surtension réglable en fonction de repos ou
de travail
• Relais de sortie pour la sous-tension en fonction de repos
(retombe en cas de sous-fréquence)
• Entrée de mesure de fréquence universel pour tensions de 40-550V
• Livrable pour diverses tensions d’alimentations
• Sur demande sans alimentation auxiliaire pour une plage de tension
de AC 18-70 ou 70-275V
• DEL de visualisation pour l’alimentation, la présence de signal
d’entrée, la sous et la surfréquence
• MH 9143.38/008: sortie analogique et une barre de visualisation pour
l'indication de la valeur actuelle de l'isolement
• 2 versions au choix:
MK 9143N et MK 9143N/600: 2 x 1 INV, Largeur utile 22,5 mm
MH 9143 et MH 9143/600: 2 x 2 INV, Largeur utile 45 mm
• Recognizes fuse failures in three-phase mains up to 3 AC 690 V
• Can be used for all types and sizes of fuses
• Independent of phase sequence
• Signals even if loads are switched off
• No malfunction on
- asymmetrical mains
- mains with harmonic waves
- motors producing feedback
• Shorter response time than with motor circuit-breakers
• Green LED for intact fuses
• Red LED for fuse failure
• As option: open/closed circuit operation in the case
of IP 9075 programmable via X4-X5 or X3-X4
• As option: with manual reset function and remote reset,
programmable via X1-X2
• As option: 1 NO contact or 2 changeover contacts
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IL 9075, SL 9075: width 35 mm
IP 9075, SP 9075: width 70 mm
• Monitoring of AC voltage for under and overfrequency,
can be used also for pre-warning
• Separate relay outputs for over- or underfrequency
(1 or 2 changeover contacts each)
• Alternative usage for monitoring of a frequency window
• Separate adjustment of response value for over- or underfrequency
at 4 ranges each, 1.5 ... 200 Hz or 5 ... 600 Hz
• Second response value for prewarning possible
• Fast reaction time by measuring duration of cycle of input frequency
• Universal measuring input for AC-voltages of 15 ... 280 V
as well as 30 ... 550 V
• As option with measuring input for inverters
• Programmable hysteresis of response value: 2 ... 10 %
• Start up time delay programmable via terminals from
0 ... 50 s e.g. continuously
• Manual or auto-reset programmable via terminals
• Galvanic separation between measuring input, auxiliary voltage
and output contacts
• MH 9837/508: with galvanic separated analogue output (current/
voltage) and 11 step LED chain for the actual frequency
• MH 9837/5_0: with wide input range for auxiliary voltage available
(AC/DC 24 ... 60 V or AC/DC 110 ... 230 V)
• Closed circuit operation (de-energized on trip)
• LED indication for auxiliary voltage, measuring voltage and
alarm status
• Device available with 2 contacts
MK 9837N/5_0: 2 x 1 changeover contact
MH 9837/5_0: 2 x 2 changeover contacts or
wide auxiliary voltage range
• 2 possible compact designs:
MK 9837N/5_0: Width 22,5 mm
MH 9837/5_0: Width 45 mm
• Recognizes fuse failures in three-phase mains up to 3 AC 690 V
• Can be used for all types and sizes of fuses
• Independent of phase sequence
• Signals even if loads are switched off
• No malfunction on
- asymmetrical mains
- mains with harmonic waves
- motors producing feedback
• Shorter response time than with motor circuit-breakers
• Green LED for intact fuses
• Red LED for fuse failure
• As option: open/closed circuit operation in the case
of IP 9075 programmable via X4-X5 or X3-X4
• As option: with manual reset function and remote reset,
programmable via X1-X2
• As option: 1 NO contact or 2 changeover contacts
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IL 9075, SL 9075: width 35 mm
IP 9075, SP 9075: width 70 mm
• Detection of under- or overfrequency
• Adjustable response value
• Optionally 1 or 2 changeover contacts
• Width 45 mm
Maximum functionality for your application
DOLD offers custom solutions for the monitoring of electrical variables such as current, voltage, power, resistance, et cetera. The measuring relays report error conditions and thus offer increased protection even for complex systems as well a ensure an optimal production process. LEDs on the front of the device provide you with optimal information about the current condition. We can provide you with both mono-functional and multifunctional relays with which you can realise your solutions with minimal costs or maximum flexibility and functionality.