Measuring and monitoring relays DOLD

Показано товаров: 20 из 180
Артикул: 1324999
• According to IEC/EN 60 255, DIN VDE 0435-303
• Fast detection of undervoltage and phase failure in AC voltage
systems
• Detects voltage drops (reaction time ≤ 20 ms)
• Response value 0.8 or 0.7 UN selectable by wire link
• Without auxiliary supply
• De-energized on trip
• LED indicator for contact position
• Adjustable operate delay after return of voltage
• As option adjustable fleeting on make pulse after return of voltage
(variant BC 9190N.11/001)
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3/-4
• Width 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324998
• According to EC/EN 60255-1, IEC/EN 60255-26, VDE 0435 part 303
• 3-phase
• For nominal voltage of 3 AC 100 / 57 to 690 / 400 V
• Measures arithmetic mean value
• Adjustable operate and release value
• For 3p3w or 3p4w systems
• BA 9043 optionally with adjustable time delay
• Closed circuit operation
• LED indicator for operation and state of contact
• Insensitive to harmonics
• Frequency up to 400 Hz
• Width 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324997
• According to EC/EN 60255-1, IEC/EN 60255-26, VDE 0435 part 303
• 3-phase
• For nominal voltage of 3 AC 100 / 57 to 690 / 400 V
• Measures arithmetic mean value
• Adjustable operate and release value
• For 3p3w or 3p4w systems
• BA 9043 optionally with adjustable time delay
• Closed circuit operation
• LED indicator for operation and state of contact
• Insensitive to harmonics
• Frequency up to 400 Hz
• Width 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325008
• According to IEC/EN 60255-1
• For installations according to DIN VDE 0100-718 and DIN VDE 0108-100
(replacement of DIN VDE 0108 )
• Detection of undervoltage in 3-phase systems
• Without separately auxiliary voltage
(internal supply from all 3 phases)
• LED indication for für operation voltage and contact position
• De-energised on trip
• RK 9871.71: 1 changeover contact
RK 9871.72: 2 changeover contacts
• With fixed time delay of 0.5s for fault indication
• With fixed time delay of 1min for reset
• With fixed response value at AC 195.5V
• As option with test-button for function control
• Width 17,5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324996
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of overvoltage
• Without auxiliary supply
• Settable response value
• De-energized on trip
• LED indicator for state of output relay
• 1 changeover contact
• As option energized on trip
• As option with delay t1 on trip
• As option with delay t2 on reset
• Devices available in 2 enclosure versions:
IK 9171: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9171: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324995
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of overvoltage
• Without auxiliary supply
• Settable response value
• De-energized on trip
• LED indicator for state of output relay
• 1 changeover contact
• As option energized on trip
• As option with delay t1 on trip
• As option with delay t2 on reset
• Devices available in 2 enclosure versions:
IK 9171: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9171: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324994
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of overvoltage in 3-phase systems
• Also for single phase
• Without auxiliary supply
• Settable response value
• N.C. circuit operation (optionally N.O. circuit operation)
• Optionally with or without N
• Optionally with delay t1 on trip
• Optionally with delay t2 on reset
• LED indicator for state of output relay
• Indepenent of phase sequence
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9170: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9170: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324993
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of overvoltage in 3-phase systems
• Also for single phase
• Without auxiliary supply
• Settable response value
• N.C. circuit operation (optionally N.O. circuit operation)
• Optionally with or without N
• Optionally with delay t1 on trip
• Optionally with delay t2 on reset
• LED indicator for state of output relay
• Indepenent of phase sequence
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9170: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9170: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325007
• According to IEC/EN 60 255, DIN VDE 0435-303
• Identification of
- undervoltage
- phase failure
- asymmetry also with reverse voltage
- missing neutral in the system
- broken neutral on IL/SL 9071
- neutral exchanged against phase
• Single phase connection possible
• According to DIN VDE 0100-710
(for rooms used for medical purposes) as an option
• Fixed setting value (variable as an option)
• Closed circuit operation principle
• LED indicator
• With safe disconnection according to IEC/EN 61 140,
IEC/EN 60 947-1 between the Measuring Circuit and the contacts
• Independant of phase sequence
• 2 changeover contacts
• Devices available in 2 enclosure version:
IL 9071: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution
systems according to DIN 43 880
SL 9071: depth 98 mm with terminals at the top for
cabinets with mounting plate and cable duct
• Width 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324992
• According to IEC/EN 60 255-1
• For monitoring direct current voltage supply systems
to detect residual ripple
• For DC 48 V
• With adjustable residual ripple
• LED indication for operation and contact position
• Time delay 10 s
• 1 changeover contact
• Width: 22,5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324991
• According to IEC/EN 60 255, DIN VDE 0435-303
• For monitoring direct current voltage supply systems to detect
undervoltage, overvoltage and residual ripple
• For DC 24 V
• IK 9046 with adjustable residual ripple
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324990
• According to IEC/EN 60 255, DIN VDE 0435-303
• For monitoring direct current voltage supply systems to detect
undervoltage, overvoltage and residual ripple
• For DC 24 V
• IK 9046 with adjustable residual ripple
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325006
• According to IEC/EN 60 255, DIN VDE 0435-303
• Identification of
- undervoltage
- phase failure
- asymmetry also with reverse voltage
- missing neutral in the system
- broken neutral on IL/SL 9071
- neutral exchanged against phase
• Single phase connection possible
• According to DIN VDE 0100-710
(for rooms used for medical purposes) as an option
• Fixed setting value (variable as an option)
• Closed circuit operation principle
• LED indicator
• With safe disconnection according to IEC/EN 61 140,
IEC/EN 60 947-1 between the Measuring Circuit and the contacts
• Independant of phase sequence
• 2 changeover contacts
• Devices available in 2 enclosure version:
IL 9071: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution
systems according to DIN 43 880
SL 9071: depth 98 mm with terminals at the top for
cabinets with mounting plate and cable duct
• Width 35 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324989
• According to IEC 255, EN 30 255, VDE 0435 part 303
• Single phase
• Measuring ranges from 24 to 660 V
• Response and release value adjustable independent of each other
• Under- and overvoltage detection
• Without auxiliary supply
• Large setting range
• With time delay
• Closed circuit operation
• Insensitive to harmonics
• LED indicators for operation and state of contacts
• Width 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324988
• According to IEC/EN 60255-1, IEC/EN 60255-26, VDE 0435 part 303
• Single-phase
• Measuring ranges from 24 to 400
• Settable response and release value
• Without auxiliary supply
• optionally available with adjustable time delay
• with LED indicators for operation and state of contacts
• 2 changeover contacts
• Width 45 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324987
• According to IEC/EN 60 255, DIN VDE 0435-303, IEC/EN 60 947-1
• to: monitor DC and AC
• BA 9054 with measuring ranges from 15 mV to 1000 V
• MK 9054N with measuring ranges from 15 mV to 500 V
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between Auxiliary Circuit – measuring ciruit
• Auxiliary supply AC/DC; BA 9054 with AC
• BA 9054 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9054 optionally with safe separation to IEC/EN 61140
• MK 9054N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9054N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9054: 45 mm
Width MK 9054N: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1325005
• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of undervoltage
• Without auxiliary supply
• Optionally fixed or settable response value
• N.C. circuit operation
• Optionally with off-delay t1
• Optionally with on-delay t2
• LED indicator for state of output relay
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9173: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9173: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324986
• According to IEC/EN 60 255, DIN VDE 0435-303, IEC/EN 60 947-1
• to: monitor DC and AC
• BA 9054 with measuring ranges from 15 mV to 1000 V
• MK 9054N with measuring ranges from 15 mV to 500 V
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between Auxiliary Circuit – measuring ciruit
• Auxiliary supply AC/DC; BA 9054 with AC
• BA 9054 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9054 optionally with safe separation to IEC/EN 61140
• MK 9054N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9054N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9054: 45 mm
Width MK 9054N: 22.5 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324985
• AC/DC voltage measuring (single-phase)
• Start up delay, on delay
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9064N: 1 changeover contact
MH 9064: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• With RS485 (on request)
• Width MK 9064N: 22.5 mm
• Width MH 9064: 45.0 mm
В корзину

Товар в корзине.

Перейти в корзину
Артикул: 1324984
• AC/DC voltage measuring (single-phase)
• Start up delay, on delay
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9064N: 1 changeover contact
MH 9064: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• With RS485 (on request)
• Width MK 9064N: 22.5 mm
• Width MH 9064: 45.0 mm
В корзину

Товар в корзине.

Перейти в корзину

Maximum functionality for your application

DOLD offers custom solutions for the monitoring of electrical variables such as current, voltage, power, resistance, et cetera. The measuring relays report error conditions and thus offer increased protection even for complex systems as well a ensure an optimal production process. LEDs on the front of the device provide you with optimal information about the current condition. We can provide you with both mono-functional and multifunctional relays with which you can realise your solutions with minimal costs or maximum flexibility and functionality.