Monitoring devices DOLD
Insulation monitors (20)
Fault annunciators (26)
Accessories (5)
• optionally with switchable interval- / permanent sound
• Devices available in 2 enclosure versions:
- I- and-version, e.g. IK _ _ _ _ with depth 61 mm, with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880, - S-version, e.g. SK _ _ _ _ with depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width: 17,5 mm
• Exchangable front label for individual legending
• As option galvanic separated RS458 bus
• Protection degree for front side IP 64
• Enclosure for flush mounting 96 x 96 mm
• Display unit EH 5994:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm, common alarm and alarm signal
• Display unit EH 5995:
- 8 fault signal LEDs on the unit
- Without reset buttons
• Exchangable front label for individual legending
• As option galvanic separated RS458 bus
• Protection degree for front side IP64
• Enclosure for flush mounting 96 x 96 mm
• Display Unit EH 5990:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm and common alarm
• Display Unit EH 5991:
- 8 fault signal LEDs on the unit
- Without reset buttons
• Common alarm annunciator
• Expandable from 4 up to 160 inputs
• Open circuit inputs / closed circuit inputs selectable via bridges X1-X2
• Delayed inputs up to 10 s
• Acknowledgement push button QH for external buzzer built in
• Accessories: Buzzer IK 8832, SK 8832
• Devices available in 2 enclosure versions:
I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width 35 mm
Extension unit IL 5991, SL 5991:
• 4 inputs with LED on control unit
• 4 digital inputs and 4 relay outputs
• Variant RP 5812/001 with 2 digital and 2 analogue inputs and 1 analogue - and 2 relay outputs
• Auxiliary voltage DC 24 V
• DC 24 V digital inputs
• Automatic SMS messages for status changes
• Quad-Band GSM-Module for 850, 900, 1800 and 1900 MHz (GSM = Global System for Mobile)
• Pin protection of SIM card
• Caller password protection against unauthorised access
• User Dialogue language for: German, English or French
• Configurable authorization levels for up to 16 users
• Assignment of different I/O’s to different users
• Automatic sending of SMS when digital inputs change state I.e. come on or go off or both (on rising edge or falling edge)
• Automatic sending of SMS when analogue inputs
- exceed preset lower and upper limits or
- when signal is within the preset window
- and when the signal returns to good state
• Adjustable
- Hysteresis for analogue inputs
- Time delay for each input
- Repeat time for SMS-transmitting
- Time delay for output status after starting the unit
- Time delay for activation of the output
• SMS for device status to the system administrators
• SMS-counter to monitor the remaining account
• No interruption of operation after Voltage failure due to integrated Li-Ion battery backup 24Hours
• Compact width: 70 mm
• Exchangable front label for individual legending
• As option galvanic separated RS458 bus
• Protection degree for front side IP64
• Enclosure for flush mounting 96 x 96 mm
• Display Unit EH 5990:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm and common alarm
• Display Unit EH 5991:
- 8 fault signal LEDs on the unit
- Without reset buttons
• Expandable from 3 up to 303 inputs
• Width 45 mm
Fault annunciator AD 5998:
• 3 inputs
• Pushbutton connection possible for light signal acknowledgement,
horn acknowledgement and lamp test
• 1 relay for common alarm and 1 for horn
Extension unit AD 5992:
• 6 inputs
• Expandable from 3 up to 303 inputs
• Width 45 mm
Fault annunciator AD 5998:
• 3 inputs
• Pushbutton connection possible for light signal acknowledgement,
horn acknowledgement and lamp test
• 1 relay for common alarm and 1 for horn
Extension unit AD 5992:
• 6 inputs
according to DIN 19 235
• Expandable from 16 up to 160 inputs
• in 2 groups of 8 inputs selectable:
- open circuit operation
- closed circuit operation
• Input voltage up to max. AC/DC 240 V
• Delayed inputs
• Exchangable front for individual scale
• Removable terminals
• Flush mounting
• Frame 72 x 144 mm
• Fast localisation of failures and their causes
• Reduction of standstill times in production
• Adjustable operating modes:
New- / First signal annunciator according to DIN 19 235,
common alarm annunciator manual reset / auto reset settable
• Expandable from 8 to 88 fault signals
• Open or closed circuit operation settable
• Adjustable on delay for input signals 0 to 10 sec
• Reset buttons for audible alarm and common alarm on front side
• Connection for external reset of audible alarm, common alarm
and single alarm according to setting
• Galvanic separation to bus RS485 (optional)
• Accessories: buzzer RK 8832, display unit EH 5994, EH 5995
text display unit EH 5996, GMS-module RP 5810
• Width: 70 mm
Base module RP 5994:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
Extension module RP 5995:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm (on request)
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
• It shows the actual insulation resistance of the voltage system to ground
• Dimensions Width x heigth x depth: 96 x 96 x 52 mm
• Extension of nominal voltage range to DC max. 1000 V, AC max. 760 V
• Weight: approx. 110 g
• Dimensions Width x height x depth: 70 x 90 x 71 mm
DIN rail mounting or screw-type mounting
• Mounting on the top-hat rail may be done horizontally or vertically
DIN rail mounting or screw-type mounting
• Mounting on the top-hat rail may be done horizontally or vertically
DIN rail mounting or screw-type mounting
• Mounting on the top-hat rail may be done horizontally or vertically

Early detection of critical limit value violations
DOLD offers you a comprehensive offer of measuring and monitoring relays for your individual needs. The devices detect and provide early notification if critical limits of electrical variables such as current, voltage, power, insulation resistance, et cetera are violated. This allows dangers to people and machinery to be reliably avoided. In addition, the availability of your machines and systems will be increased and production outages will be minimised. DOLD's portfolio ranges from standard devices for the monitoring of individual variables to multifunctional devices to flexible error message systems.
Свяжитесь с нами
Если вы не нашли нужной информации на сайте или у вас остались вопросы по товарам, оставьте заявку на бесплатную консультацию, и мы вам перезвоним









Ответ от производителя может занять до 5 дней и более.