Monitoring devices DOLD
Insulation monitors (20)
Fault annunciators (26)
Accessories (5)
• Single phase
• Measuring ranges from 24 to 660 V
• Response and release value adjustable independent of each other
• Under- and overvoltage detection
• Without auxiliary supply
• Large setting range
• With time delay
• Closed circuit operation
• Insensitive to harmonics
• LED indicators for operation and state of contacts
• Width 45 mm
• Single-phase
• Measuring ranges from 24 to 400
• Settable response and release value
• Without auxiliary supply
• optionally available with adjustable time delay
• with LED indicators for operation and state of contacts
• 2 changeover contacts
• Width 45 mm
• to: monitor DC and AC
• BA 9054 with measuring ranges from 15 mV to 1000 V
• MK 9054N with measuring ranges from 15 mV to 500 V
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between Auxiliary Circuit – measuring ciruit
• Auxiliary supply AC/DC; BA 9054 with AC
• BA 9054 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9054 optionally with safe separation to IEC/EN 61140
• MK 9054N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9054N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9054: 45 mm
Width MK 9054N: 22.5 mm
• Monitoring of undervoltage
• Without auxiliary supply
• Optionally fixed or settable response value
• N.C. circuit operation
• Optionally with off-delay t1
• Optionally with on-delay t2
• LED indicator for state of output relay
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9173: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9173: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• to: monitor DC and AC
• BA 9054 with measuring ranges from 15 mV to 1000 V
• MK 9054N with measuring ranges from 15 mV to 500 V
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between Auxiliary Circuit – measuring ciruit
• Auxiliary supply AC/DC; BA 9054 with AC
• BA 9054 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9054 optionally with safe separation to IEC/EN 61140
• MK 9054N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9054N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9054: 45 mm
Width MK 9054N: 22.5 mm
• Start up delay, on delay
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9064N: 1 changeover contact
MH 9064: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• With RS485 (on request)
• Width MK 9064N: 22.5 mm
• Width MH 9064: 45.0 mm
• Start up delay, on delay
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9064N: 1 changeover contact
MH 9064: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• With RS485 (on request)
• Width MK 9064N: 22.5 mm
• Width MH 9064: 45.0 mm
• For DC monitoring
• Detection of
- Overvoltage
- Untervoltage
- Voltage range excess in single-phase AC voltage systems
• No separate auxiliary necessary
• Output: 1 changeover contact
• De-energized on trip
• Adjustable switching voltage
• Adjustable hysteresis for reset
• Adjustable switching delay
• Fast fault detection
• Width: 35 mm
• For DC monitoring
• Detection of
- Overvoltage
- Untervoltage
- Voltage range excess in single-phase AC voltage systems
• No separate auxiliary necessary
• Output: 1 changeover contact
• De-energized on trip
• Adjustable switching voltage
• Adjustable hysteresis for reset
• Adjustable switching delay
• Fast fault detection
• Width: 35 mm
• Effective power measuring
• For single and 3-phases
• Adjustable response value 2 ... 20 % reverse power
• Hysteresis 12.5 %
• Rated current BH 9140: 5 A or 40 A
Rated current RP 9140: 5 A
• Adjustable on delay
• Open circuit operation
• LED indication for voltage supply and contact position
• 2 changeover contacts
• As option closed circuit operation
• Width:
BH 9140: 45 mm
RP 9140: 70 mm
• Effective power measuring
• For single and 3-phases
• Adjustable response value 2 ... 20 % reverse power
• Hysteresis 12.5 %
• Rated current BH 9140: 5 A or 40 A
Rated current RP 9140: 5 A
• Adjustable on delay
• Open circuit operation
• LED indication for voltage supply and contact position
• 2 changeover contacts
• As option closed circuit operation
• Width:
BH 9140: 45 mm
RP 9140: 70 mm
• Detection of underload (cos ϕ)
• Without auxiliary supply
• Current up to 8 A
Motors up to 5 A nominal current can be connected directly
• Higher currents via current transformer
• SL 9065CT with integrated current transformer for currents up to 100 A
• Adjustable response value
• Automatic reset (Alarm auto reset)
• Adjustable operate delay up to 100 s
• De-energized on trip
• For single and 3-phase loads e.g. motors
• Independent of phase sequence
• 1 changeover contact
• LED indicator voltage supply and alarm
• Devices available in 2 enclosure versions: IK 9065: depth 58 mm,
with terminals at the bottom for installation systems and industrial
distribution systems according to DIN 43 880
SK 9065, SL 9065CT: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9065, SK 9065 width 17.5 mm
SL 9065CT width 35 mm
IK/SK 9065/100: as IK/SK 9065 but:
• programmable for
- automatic reset or manual reset (latched alarm)
- energized or de-energized on trip
• with reset button
• remote reset
• Detection of underload (cos ϕ)
• Without auxiliary supply
• Current up to 8 A
Motors up to 5 A nominal current can be connected directly
• Higher currents via current transformer
• SL 9065CT with integrated current transformer for currents up to 100 A
• Adjustable response value
• Automatic reset (Alarm auto reset)
• Adjustable operate delay up to 100 s
• De-energized on trip
• For single and 3-phase loads e.g. motors
• Independent of phase sequence
• 1 changeover contact
• LED indicator voltage supply and alarm
• Devices available in 2 enclosure versions: IK 9065: depth 58 mm,
with terminals at the bottom for installation systems and industrial
distribution systems according to DIN 43 880
SK 9065, SL 9065CT: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9065, SK 9065 width 17.5 mm
SL 9065CT width 35 mm
IK/SK 9065/100: as IK/SK 9065 but:
• programmable for
- automatic reset or manual reset (latched alarm)
- energized or de-energized on trip
• with reset button
• remote reset
• Detection of underload (cos ϕ)
• Without auxiliary supply
• Current up to 8 A
Motors up to 5 A nominal current can be connected directly
• Higher currents via current transformer
• SL 9065CT with integrated current transformer for currents up to 100 A
• Adjustable response value
• Automatic reset (Alarm auto reset)
• Adjustable operate delay up to 100 s
• De-energized on trip
• For single and 3-phase loads e.g. motors
• Independent of phase sequence
• 1 changeover contact
• LED indicator voltage supply and alarm
• Devices available in 2 enclosure versions: IK 9065: depth 58 mm,
with terminals at the bottom for installation systems and industrial
distribution systems according to DIN 43 880
SK 9065, SL 9065CT: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9065, SK 9065 width 17.5 mm
SL 9065CT width 35 mm
IK/SK 9065/100: as IK/SK 9065 but:
• programmable for
- automatic reset or manual reset (latched alarm)
- energized or de-energized on trip
• with reset button
• remote reset
• Detection of underload (cos ϕ)
• Current ranges up to 10 A
• Adjustable response value
• Programmable functions:
- automatic or manual reset
- closed or open circuit operation
• Manual remote reset
• Adjustable operate delay up to 100 s
• For single and 3-phase AC-systems without neutral
• Independent of phase sequence
• Also for 400 Hz systems
• MK 9065.11 can be used for motors with frequency converters
2 ... 200 Hz)
• Optionally with sealable cover
• Green indicator LED for operational mode
• Red indicator LED for underload monitoring
• Width 22.5 mm
• Detection of underload (cos ϕ)
• Current ranges up to 10 A, for higher values a CT must be used
• Adjustable response value
• Programmable functions:
- alarm when I = 0
- automatic or manual reset
- closed or open circuit operation
• Manual remote reset
• Adjustable operate delay
• Independent of phase sequence
• Also for 400 Hz systems
• Optionally for motors with frequency converters (10 ... 100 Hz)
(see notes)
• Width 45 mm
• As load depending output signals are available
- 0 ... 20 mA and 0 ... 10 V or
- 4 ... 20 mA and 2 ... 10 V
• Measures effective load
• Adjustment of P1 and P2 on absolute scale
• For motors up to 22 kW / 400 V bzw. 37 kW / 690 V
• Adjustable start up delay ta
• Up to 40 A without external current transformer
• As option for single phase loads
• LED indicators
• Width 45 mm
• Identification of
- Underload P1 and Overload P2
- Overload P1 (prewarning) and Overload P2
programmable
• Adjustment of P1 and P2 on absolute scale
• For motors up to 22 kW / 400 V; 37 kW / 600 V
• Measurement: effective power
• Large current range because of automatic range selection
• 1 changeover contact for P1 and 1 changeover contact for P2
• Adjustable start-up delay ta
• Adjustable switching delay tv
• With automatic or manual reset, programmable
• Test / Reset button for easy setup
• Up to 40 A without external current transformer
• De-energized or energized on fault, programmable
• Also for single-phase operation
• LED indicators
• Width 45 mm
• Active power measuring
• Relay output
MK 9397N: 1 changeover contact
MH 9397: 1 changeover contact each for overload and prewarning
• On delay
• Closed circuit operation
• As option open circuit operation
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• MK 9397N: Width 22,5 mm
MH 9397: Width 45 mm
• Active power measuring
• Relay output
MK 9397N: 1 changeover contact
MH 9397: 1 changeover contact each for overload and prewarning
• On delay
• Closed circuit operation
• As option open circuit operation
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• MK 9397N: Width 22,5 mm
MH 9397: Width 45 mm

Early detection of critical limit value violations
DOLD offers you a comprehensive offer of measuring and monitoring relays for your individual needs. The devices detect and provide early notification if critical limits of electrical variables such as current, voltage, power, insulation resistance, et cetera are violated. This allows dangers to people and machinery to be reliably avoided. In addition, the availability of your machines and systems will be increased and production outages will be minimised. DOLD's portfolio ranges from standard devices for the monitoring of individual variables to multifunctional devices to flexible error message systems.