Monitoring devices DOLD
Insulation monitors (20)
Fault annunciators (26)
Accessories (5)
• For monitoring of current in DC and AC systems
• Detection of over- or undercurrent in AC- or DC mains
• Wide auxiliary range
• Output: 1 changeover contact
• De-Energized on trip
• Adjustable switching current
• Adjustable hysteresis for reset
• Adjustable switching delay
• Fast fault detection
• Width: 35 mm
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• 3 probe connections for 2-point and 1-point level control
• Also for use as moisture detector
• High interference resistance of the Measuring Circuit,
which is isolated from the mains
• Max. wire length to the probes: 1500 m
• Large setting range: 2 ... 450 kΩ
this permits differentiation between fluid and foam
• Separately adjustable response and release time delay
0.2 ... 20 s for MIN- and MAX-level
• Programmable for:
- 2 separate controllable output relays for MIN and MAX level
- common controlled output relays for 2-point hysteresis
level control
- open circuit operation
- closed circuit operation
• Measuring Circuit for probes works with internally generated
AC voltage (approx. 30 Hz), electrolytic behaviour does not
occur in the liquid
• For auxiliary voltages of 24 ... 415 V AC or 24 V DC
• LEDs for operation and state of contact
• 2 changeover relays with 1 changeover contact each
• IL 9151 and SL 9151 with safe separation according to
IEC/EN 61 140, IEC/EN 60 947-1
• Devices available in 3 enclosure versions:
IL 9151: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9151,
MK 9151N: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IL/SL 9151: 35 mm width
MK 9151N: 22.5 mm width
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
• 3 probe connections for 2-point and 1-point level control
• Also for use as moisture detector
• High interference resistance of the Measuring Circuit,
which is isolated from the mains
• Max. wire length to the probes: 1500 m
• Large setting range: 2 ... 450 kΩ
this permits differentiation between fluid and foam
• Separately adjustable response and release time delay
0.2 ... 20 s for MIN- and MAX-level
• Programmable for:
- 2 separate controllable output relays for MIN and MAX level
- common controlled output relays for 2-point hysteresis
level control
- open circuit operation
- closed circuit operation
• Measuring Circuit for probes works with internally generated
AC voltage (approx. 30 Hz), electrolytic behaviour does not
occur in the liquid
• For auxiliary voltages of 24 ... 415 V AC or 24 V DC
• LEDs for operation and state of contact
• 2 changeover relays with 1 changeover contact each
• IL 9151 and SL 9151 with safe separation according to
IEC/EN 61 140, IEC/EN 60 947-1
• Devices available in 3 enclosure versions:
IL 9151: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9151,
MK 9151N: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IL/SL 9151: 35 mm width
MK 9151N: 22.5 mm width
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• Monitioring of
- overtemperature
- broken wire detection in sensor circuit
- short circuit detection in sensor circuit
• 1 input for 1 to 6 PTC-resistors
• De-energized on trip
• LED-indicator for
- auxiliary supply
- state of contact
• Output with 2 changeover contacts
• As option with manual reset, internal reset button and external
remote reset X1/X2
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
• 3 probe connections for 2-point and 1-point level control
• Also for use as moisture detector
• High interference resistance of the Measuring Circuit,
which is isolated from the mains
• Max. wire length to the probes: 1500 m
• Large setting range: 2 ... 450 kΩ
this permits differentiation between fluid and foam
• Separately adjustable response and release time delay
0.2 ... 20 s for MIN- and MAX-level
• Programmable for:
- 2 separate controllable output relays for MIN and MAX level
- common controlled output relays for 2-point hysteresis
level control
- open circuit operation
- closed circuit operation
• Measuring Circuit for probes works with internally generated
AC voltage (approx. 30 Hz), electrolytic behaviour does not
occur in the liquid
• For auxiliary voltages of 24 ... 415 V AC or 24 V DC
• LEDs for operation and state of contact
• 2 changeover relays with 1 changeover contact each
• IL 9151 and SL 9151 with safe separation according to
IEC/EN 61 140, IEC/EN 60 947-1
• Devices available in 3 enclosure versions:
IL 9151: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9151,
MK 9151N: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IL/SL 9151: 35 mm width
MK 9151N: 22.5 mm width
• Detection of over- or underspeed or frequency, function
selectable
• 3 selectable ranges for frequency or speed, adjustable tripping
value
• Ranges up to 10 kHz ( 600.000 ipm) available,therefore suitable
for turbines, centrifuges and similar applications
• Adjustable hysteresis
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• As option for permanent magnet sensors
• As option with adjustable switching delay/start up delay
• On request with manual reset
• IK 9055 and SK 9055: compact version for DC 24 V auxiliary
supply
• IL 9055 and SL 9055: for auxiliary supply up to AC 400 V with
galvanic separation to sensor input
• De-energized on trip (Energized on trip on request)
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9055: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9055: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9055, SK 9055: width 17.5 mm
• IL 9055, SL 9055: width 35 mm
• Easy setting
• Universal input, for configuration of different sensors
(PNP, NPN, 2-wire, contact, voltage)
• Detection of
- underspeed
- overspeed
- standstill
• Adjustable response value
• BA 9055 with adjustable start-up delay
• AA 9050 with adjustable hysteresis
• Width 45 mm
• Monitoring of:
-- overtemperature
-- broken wire detection in sensor circuit
• 1 input for 1 to 6 PTC-resistors
• With manual reset variant /100
• Optionally with button for reset and test function
• Remote reset on A1/A2 (NC contact) or
X1/X2 (NO contact)
• Closed circuit operation
• LED indicator for
-- auxiliary supply
-- state of contact
• 2 changover contacts
• Devices available in 2 enclosure versions:
IL 9163: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9163: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 35 mm
• Detection of over- or underspeed or frequency, function
selectable
• 3 selectable ranges for frequency or speed, adjustable tripping
value
• Ranges up to 10 kHz ( 600.000 ipm) available,therefore suitable
for turbines, centrifuges and similar applications
• Adjustable hysteresis
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• As option for permanent magnet sensors
• As option with adjustable switching delay/start up delay
• On request with manual reset
• IK 9055 and SK 9055: compact version for DC 24 V auxiliary
supply
• IL 9055 and SL 9055: for auxiliary supply up to AC 400 V with
galvanic separation to sensor input
• De-energized on trip (Energized on trip on request)
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9055: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9055: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9055, SK 9055: width 17.5 mm
• IL 9055, SL 9055: width 35 mm
• Detection of
- underspeed
- overspeed
- standstill
• Adjustable response value
• BA 9055 with adjustable start-up delay
• AA 9050 with adjustable hysteresis
• Width 45 mm
• Detection of standstill of rotating machine parts and cyclic pulses
• Detection of blocking or missing pulses
• Monitoring time adjustable between 0.1 ... 20 s (others on request)
• Energized or de-energized on trip
• For input frequency up to 5 kHz( 300000 ipm)
• Universal input, suitable for a variety of sensors
(PNP,NPN,2-wire, contact, voltage)
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• On request with manual reset
• IK 9144 and SK 9144: compact version for DC 24V auxiliary supply
• IL 9144 and SL 9144: for auxiliary supply up to AC 400V with
galvanic separation to sensor input
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9144: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9144: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9144, SK 9144: width 17.5 mm
• IL 9144, SL 9144: width 35 mm
• Detection of over- or underspeed or frequency, function
selectable
• 3 selectable ranges for frequency or speed, adjustable tripping
value
• Ranges up to 10 kHz ( 600.000 ipm) available,therefore suitable
for turbines, centrifuges and similar applications
• Adjustable hysteresis
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• As option for permanent magnet sensors
• As option with adjustable switching delay/start up delay
• On request with manual reset
• IK 9055 and SK 9055: compact version for DC 24 V auxiliary
supply
• IL 9055 and SL 9055: for auxiliary supply up to AC 400 V with
galvanic separation to sensor input
• De-energized on trip (Energized on trip on request)
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9055: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9055: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9055, SK 9055: width 17.5 mm
• IL 9055, SL 9055: width 35 mm
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• de-energized on trip
• energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
• Detection of standstill of rotating machine parts and cyclic pulses
• Detection of blocking or missing pulses
• Monitoring time adjustable between 0.1 ... 20 s (others on request)
• Energized or de-energized on trip
• For input frequency up to 5 kHz( 300000 ipm)
• Universal input, suitable for a variety of sensors
(PNP,NPN,2-wire, contact, voltage)
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• On request with manual reset
• IK 9144 and SK 9144: compact version for DC 24V auxiliary supply
• IL 9144 and SL 9144: for auxiliary supply up to AC 400V with
galvanic separation to sensor input
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9144: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9144: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9144, SK 9144: width 17.5 mm
• IL 9144, SL 9144: width 35 mm

Early detection of critical limit value violations
DOLD offers you a comprehensive offer of measuring and monitoring relays for your individual needs. The devices detect and provide early notification if critical limits of electrical variables such as current, voltage, power, insulation resistance, et cetera are violated. This allows dangers to people and machinery to be reliably avoided. In addition, the availability of your machines and systems will be increased and production outages will be minimised. DOLD's portfolio ranges from standard devices for the monitoring of individual variables to multifunctional devices to flexible error message systems.