Monitoring devices DOLD
Insulation monitors (20)
Fault annunciators (26)
Accessories (5)
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 10000 Hz
• Adjustable tripping value RAL of 5 ... 100 kΩ
• Monitors also disconnected voltage systems
• De-energized on trip
• Auxiliary voltage Measuring Circuit and output contacts are galvanically separated
• Manual and auto reset
• With test and reset button
• Connections of external test and reset buttons possible
• LED indicators for operation and alarm
• 2 changeover contacts
• IL/SL 5880/200 with additional prewarning
- adjustable prewarning value 10 kΩ ... 5 MΩ
- output function programmable
• Variant IL/SL 5880/300 according to DIN VDE 0100-551 for mobile generator sets available
• 4 models available:
IL 5880, IP 5880: 61 mm deep with terminals near to the bottom to be mounted in consumer units
or industrial distribution systems according to DIN 43 880
SL 5880, SP 5880: 98 mm deep with terminals near to the top to be mounted in cabinets with
mounting plate and cable ducts
• DIN rail or screw mounting
• 35 mm width
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 10000 Hz
• Adjustable tripping value RAL of 5 ... 100 kΩ
• Monitors also disconnected voltage systems
• De-energized on trip
• Auxiliary voltage Measuring Circuit and output contacts are galvanically separated
• Manual and auto reset
• With test and reset button
• Connections of external test and reset buttons possible
• LED indicators for operation and alarm
• 2 changeover contacts
• IL/SL 5880/200 with additional prewarning
- adjustable prewarning value 10 kΩ ... 5 MΩ
- output function programmable
• Variant IL/SL 5880/300 according to DIN VDE 0100-551 for mobile generator sets available
• 4 models available:
IL 5880, IP 5880: 61 mm deep with terminals near to the bottom to be mounted in consumer units
or industrial distribution systems according to DIN 43 880
SL 5880, SP 5880: 98 mm deep with terminals near to the top to be mounted in cabinets with
mounting plate and cable ducts
• DIN rail or screw mounting
• 35 mm width
• For DC voltage systems up to 12 ... 280 V
• Wide voltage range of measuring input UN DC 12 ... 280 V (on request DC 24 ... 500 V with separate auxiliary supply, Measuring range 20 ... 500 kΩ) • Adjustable tripping value RAL of
5 ... 200 kΩ
• Selective ground fault indication for L+ and L- allows fast fault finding
• Without auxiliary supply
• De-energized on trip
• 2 changeover contacts
• Automatic or manual reset, programmable
• With test and reset buttons
• Connection for external test and reset button possible
• galvanic separated AC or DC auxiliary supply available as option
• adjustable time delay as option
• 2 models available:
IL 5881: 61 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880
SL 5881: 98 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts
• 35 mm width
• Setting range 200 kΩ to 2 MΩ
• LED indicators
• Output: 1 NO contact
• De-energized on trip
• Test button for function check
• Reset button
• Input for voltage detection
• Manual reset available by bridge
• Width 45 mm
• Fixed response value RAN
• Internal reset button
• External reset and test button can be connected
• LED indicator
• 1 changeover contact
• Programmable for manual reset or hysteresis function
• Analogue output for insulating value
• External connection of indicating instrument possible
• as option de-energized on trip or energized on trip
• Width 100 mm
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current to monitor DC networks and networks with simultaneous alternating current and direct current portions present
• RS-485 bus connection to synchronise the test current analysis and optionally for the connection to the EDS measuring bus
• Control via insulation monitor via RS-485 bus or external control input possible
• Pushbutton for manual test current output
• Terminal connection for automatic test current output
• Status output of insulation fault detection via external switching output
• Width: 105 mm
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
• RS-485 bus connection to synchronise the test current output and optionally for the connection to the EDS measuring bus for reading insulation fault currents
• Status output of insulation fault detection via external switching output
• Memory characteristics adjustable via bridge Y1-Y2
• Collective signalling relay to output preliminary warning and alarm states
• Pushbutton for manual reset of alarm states as well as testing of differential current transformers and their calibration
• Terminal connection for the storage of alarm states
• Width: 105 mm
• Current monitor
• Detection of wire breakage
• Fixed switching points
• For DC 24 V
• Energized on trip
• Green LED display for operating voltage
• Red LED display for contact position
• Devices available in 2 enclosure versions:
IK 9076: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9076: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• de-energized on trip
• energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Setting value adjustable from 0.1 ... 1 IN
• Fixed hysteresis approx. 4 %
• Settable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage and contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9273: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9273: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Noise suppression of wire bound interference
• Broadband suppression of high frequencies
• For nominal voltages up to 3 AC 1000 V
• PE connection for increased suppression level
• 2 models available:
MK 5130N: depth 97 mm
LG 5130: depth 121 mm
• Width: 22.5 mm
• Detection of standstill of rotating machine parts and cyclic pulses
• Detection of blocking or missing pulses
• Monitoring time adjustable between 0.1 ... 20 s (others on request)
• Energized or de-energized on trip
• For input frequency up to 5 kHz( 300000 ipm)
• Universal input, suitable for a variety of sensors
(PNP,NPN,2-wire, contact, voltage)
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• On request with manual reset
• IK 9144 and SK 9144: compact version for DC 24V auxiliary supply
• IL 9144 and SL 9144: for auxiliary supply up to AC 400V with
galvanic separation to sensor input
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9144: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9144: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9144, SK 9144: width 17.5 mm
• IL 9144, SL 9144: width 35 mm
• Noise suppression of wire bound interference
• Broadband suppression of high frequencies
• For nominal voltages up to 3 AC 1000 V
• PE connection for increased suppression level
• 2 models available:
MK 5130N: depth 97 mm
LG 5130: depth 121 mm
• Width: 22.5 mm
• Current monitor
• Detection of wire breakage
• Fixed switching points
• For DC 24 V
• Energized on trip
• Green LED display for operating voltage
• Red LED display for contact position
• Devices available in 2 enclosure versions:
IK 9076: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9076: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
and part 303
• 1 input for PTC-resistors or bimetal contacts
• Broken wire detection in sensor circuit
• Optionally with no voltage reclosing interlock
• Closed circuit operation
• 1 or 2 changeover contacts
• Width 45 mm
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• Monitioring of
- overtemperature
- broken wire detection in sensor circuit
- short circuit detection in sensor circuit
• 1 input for 1 to 6 PTC-resistors
• De-energized on trip
• LED-indicator for
- auxiliary supply
- state of contact
• Output with 2 changeover contacts
• As option with manual reset, internal reset button and external
remote reset X1/X2
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• Detection of
- overtemperature
- broken wire in sensor circuit
- short circuit in sensor circuit
• 1 input for 1 to 6 PTC-reistors
• Functions as options or settable with DIP-switches:
- automatic reset (fault is not stored)
- manual reset (fault is stored)
- manual reset only on start-up
- manual reset on and also after start-up
• No voltage safe manual reset
• Closed circuit operation
• LED indicators for
- auxiliary supply
- contact position
- overtemperature, broken wire or short-circuit in sensor circuit
• 2 changeover contacts
• Button for reset function
• Remote reset via terminals X1 / X2 (NO contact)
• Optionally safe separation according to EN 61 140, EN 60 947-1, 6 kV/2
between:
- auxiliary voltage and measuring circuit
- auxiliary voltage and output contacts
- measuring circuit and output contacts
- the 2 changeover contacts (only with 2 changeover contacts)
• Width 22.5 mm

Early detection of critical limit value violations
DOLD offers you a comprehensive offer of measuring and monitoring relays for your individual needs. The devices detect and provide early notification if critical limits of electrical variables such as current, voltage, power, insulation resistance, et cetera are violated. This allows dangers to people and machinery to be reliably avoided. In addition, the availability of your machines and systems will be increased and production outages will be minimised. DOLD's portfolio ranges from standard devices for the monitoring of individual variables to multifunctional devices to flexible error message systems.









Ответ от производителя может занять до 5 дней и более.