Safe switching and monitoring Schmersal
Key transfer system (53)
Foot switch (6)
Enabling device (3)
Control panels (46)
Solenoid interlock (227)
Position switch (824)
Safety sensors (235)
• Electronic contact-free, coded system
• Misaligned actuation possible
• 27 mm x 108.2 mm x 35 mm
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
• 1 x Pre-wired cable 8-pole
• Actuation from top
• serial diagnostic output
• Max. 31 sensors can be wired in series.
• Electronic contact-free, coded system
• Misaligned actuation possible
• 27 mm x 108.2 mm x 35 mm
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
• 1 x connector plug M12, 8-pole
• Actuation from side
• Max. 31 sensors can be wired in series.
• Electronic contact-free, coded system
• Misaligned actuation possible
• 27 mm x 108.2 mm x 35 mm
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
• 1 x connector plug M12, 8-pole
• Actuation from top
• Max. 31 sensors can be wired in series.
• Electronic contact-free, coded system
• Misaligned actuation possible
• 27 mm x 108.2 mm x 35 mm
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
• 1 x connector plug M12, 8-pole
• Actuation from side
• serial diagnostic output
• Max. 31 sensors can be wired in series.
• Electronic contact-free, coded system
• Misaligned actuation possible
• 27 mm x 108.2 mm x 35 mm
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
• 1 x connector plug M12, 8-pole
• Actuation from top
• serial diagnostic output
• Max. 31 sensors can be wired in series.
• With door detection sensor T
• Easy and intuitive operation
• No risk of injury from protruding actuator
• No supplementary door handles required
• Does not protrude into the door opening
• Various handles available
• With door detection sensor T
• Easy and intuitive operation
• No risk of injury from protruding actuator
• No supplementary door handles required
• Does not protrude into the door opening
• Various handles available
even in de-energised condition
• Actuator for hinged guards
• With door detection sensor T
• Easy and intuitive operation
• No risk of injury from protruding actuator
• No supplementary door handles required
• Does not protrude into the door opening
• Various handles available
even in de-energised condition
• Actuator for hinged guards
• Easy and intuitive operation
• With door detection sensor T
• No risk of injury from protruding actuator
• No supplementary door handles required
• Does not protrude into the door opening
• Various handles available
• Suitable for food processing industry
• Concealed mounting possible
• 52 mm x 90 mm x 32 mm
• Long life
• no mechanical wear
• Insensitive to transverse misalignment
• Insensitive to soiling
• 3 cable entries M 20 x 1.5
• Wiring compartment
• 1 Cable entry M 20 x 1.5
• Protective shield with wide opening
• Low operating height of pedal
• High level of stability
• Good resistance to oil and petroleum spirit
• For left or right hinged doors
• 141 mm x 115 mm x 21,5 mm
• Simple mounting, suitable for all conventional profile systems (30 … 60 mm)
• 2 cable entries M 16 x 1.5
• with fixed switching angle
• Screw connection
• Max. length of the sensor chain 200 m
• Self-monitoring series-wiring of 31 sensors
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Intelligent diagnosis
• Good resistance to oil and petroleum spirit
• Wide range of alternative actuators
• 30 mm x 58,5 mm x 30 mm
• slim design
• 1 Cable entry M 20 x 1.5
• Actuation from bottom parallel to the switch, therefore only suitable for small housings.
• Double-insulated
• Mounting details to EN 50047
• Actuator heads can be repositioned by 4 x 90°
• Good resistance to oil and petroleum spirit
• For left or right hinged doors
• 141 mm x 115 mm x 21,5 mm
• Simple mounting, suitable for all conventional profile systems (30 … 60 mm)
• 2 cable entries M 16 x 1.5
• with fixed switching angle
• Good resistance to oil and petroleum spirit
• For left or right hinged doors
• 141 mm x 115 mm x 21,5 mm
• Simple mounting, suitable for all conventional profile systems (30 … 60 mm)
• 2 cable entries M 16 x 1.5
• Good resistance to oil and petroleum spirit
• For left or right hinged doors
• 141 mm x 115 mm x 21,5 mm
• Simple mounting, suitable for all conventional profile systems (30 … 60 mm)
• 2 cable entries M 16 x 1.5

Свяжитесь с нами
Если вы не нашли нужной информации на сайте или у вас остались вопросы по товарам, оставьте заявку на бесплатную консультацию, и мы вам перезвоним















Ответ от производителя может занять до 5 дней и более.

