Measuring and monitoring relays DOLD
• Current monitor
• Detection of wire breakage
• Fixed switching points
• For DC 24 V
• Energized on trip
• Green LED display for operating voltage
• Red LED display for contact position
• Devices available in 2 enclosure versions:
IK 9076: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9076: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• de-energized on trip
• energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Setting value adjustable from 0.1 ... 1 IN
• Fixed hysteresis approx. 4 %
• Settable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage and contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9273: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9273: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Noise suppression of wire bound interference
• Broadband suppression of high frequencies
• For nominal voltages up to 3 AC 1000 V
• PE connection for increased suppression level
• 2 models available:
MK 5130N: depth 97 mm
LG 5130: depth 121 mm
• Width: 22.5 mm
• Detection of standstill of rotating machine parts and cyclic pulses
• Detection of blocking or missing pulses
• Monitoring time adjustable between 0.1 ... 20 s (others on request)
• Energized or de-energized on trip
• For input frequency up to 5 kHz( 300000 ipm)
• Universal input, suitable for a variety of sensors
(PNP,NPN,2-wire, contact, voltage)
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• On request with manual reset
• IK 9144 and SK 9144: compact version for DC 24V auxiliary supply
• IL 9144 and SL 9144: for auxiliary supply up to AC 400V with
galvanic separation to sensor input
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9144: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9144: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9144, SK 9144: width 17.5 mm
• IL 9144, SL 9144: width 35 mm
• Noise suppression of wire bound interference
• Broadband suppression of high frequencies
• For nominal voltages up to 3 AC 1000 V
• PE connection for increased suppression level
• 2 models available:
MK 5130N: depth 97 mm
LG 5130: depth 121 mm
• Width: 22.5 mm
• Current monitor
• Detection of wire breakage
• Fixed switching points
• For DC 24 V
• Energized on trip
• Green LED display for operating voltage
• Red LED display for contact position
• Devices available in 2 enclosure versions:
IK 9076: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9076: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
and part 303
• 1 input for PTC-resistors or bimetal contacts
• Broken wire detection in sensor circuit
• Optionally with no voltage reclosing interlock
• Closed circuit operation
• 1 or 2 changeover contacts
• Width 45 mm
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• Monitioring of
- overtemperature
- broken wire detection in sensor circuit
- short circuit detection in sensor circuit
• 1 input for 1 to 6 PTC-resistors
• De-energized on trip
• LED-indicator for
- auxiliary supply
- state of contact
• Output with 2 changeover contacts
• As option with manual reset, internal reset button and external
remote reset X1/X2
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• Detection of
- overtemperature
- broken wire in sensor circuit
- short circuit in sensor circuit
• 1 input for 1 to 6 PTC-reistors
• Functions as options or settable with DIP-switches:
- automatic reset (fault is not stored)
- manual reset (fault is stored)
- manual reset only on start-up
- manual reset on and also after start-up
• No voltage safe manual reset
• Closed circuit operation
• LED indicators for
- auxiliary supply
- contact position
- overtemperature, broken wire or short-circuit in sensor circuit
• 2 changeover contacts
• Button for reset function
• Remote reset via terminals X1 / X2 (NO contact)
• Optionally safe separation according to EN 61 140, EN 60 947-1, 6 kV/2
between:
- auxiliary voltage and measuring circuit
- auxiliary voltage and output contacts
- measuring circuit and output contacts
- the 2 changeover contacts (only with 2 changeover contacts)
• Width 22.5 mm
• For monitoring of current in DC and AC systems
• Detection of over- or undercurrent in AC- or DC mains
• Wide auxiliary range
• Output: 1 changeover contact
• De-Energized on trip
• Adjustable switching current
• Adjustable hysteresis for reset
• Adjustable switching delay
• Fast fault detection
• Width: 35 mm
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• 3 probe connections for 2-point and 1-point level control
• Also for use as moisture detector
• High interference resistance of the Measuring Circuit,
which is isolated from the mains
• Max. wire length to the probes: 1500 m
• Large setting range: 2 ... 450 kΩ
this permits differentiation between fluid and foam
• Separately adjustable response and release time delay
0.2 ... 20 s for MIN- and MAX-level
• Programmable for:
- 2 separate controllable output relays for MIN and MAX level
- common controlled output relays for 2-point hysteresis
level control
- open circuit operation
- closed circuit operation
• Measuring Circuit for probes works with internally generated
AC voltage (approx. 30 Hz), electrolytic behaviour does not
occur in the liquid
• For auxiliary voltages of 24 ... 415 V AC or 24 V DC
• LEDs for operation and state of contact
• 2 changeover relays with 1 changeover contact each
• IL 9151 and SL 9151 with safe separation according to
IEC/EN 61 140, IEC/EN 60 947-1
• Devices available in 3 enclosure versions:
IL 9151: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9151,
MK 9151N: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IL/SL 9151: 35 mm width
MK 9151N: 22.5 mm width
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
• 3 probe connections for 2-point and 1-point level control
• Also for use as moisture detector
• High interference resistance of the Measuring Circuit,
which is isolated from the mains
• Max. wire length to the probes: 1500 m
• Large setting range: 2 ... 450 kΩ
this permits differentiation between fluid and foam
• Separately adjustable response and release time delay
0.2 ... 20 s for MIN- and MAX-level
• Programmable for:
- 2 separate controllable output relays for MIN and MAX level
- common controlled output relays for 2-point hysteresis
level control
- open circuit operation
- closed circuit operation
• Measuring Circuit for probes works with internally generated
AC voltage (approx. 30 Hz), electrolytic behaviour does not
occur in the liquid
• For auxiliary voltages of 24 ... 415 V AC or 24 V DC
• LEDs for operation and state of contact
• 2 changeover relays with 1 changeover contact each
• IL 9151 and SL 9151 with safe separation according to
IEC/EN 61 140, IEC/EN 60 947-1
• Devices available in 3 enclosure versions:
IL 9151: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SL 9151,
MK 9151N: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IL/SL 9151: 35 mm width
MK 9151N: 22.5 mm width
• 1 PT100 input, 2-wire connection
• 3 temperature ranges
• Adjustable response value
• Adjustable Hysteresis with wide range 3 ... 30 °C or 1 ... 15°C
• Broken wire detection in sensor circuit
• Programmable hysteresis or latching function via terminal X1
• IK 9094 no galvanic separation between measuring and Auxiliary Circuit
• Closed circuit operation
• LED indicator for operation and state of output relay
• 1 changeover contact
• As option with response value up to - 50°C, e.g. for refrigeration plants
• As option with galvanic separation between measuring and
Auxiliary Circuit
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• IK 9094, SK 9094: 17.5 mm width
IL 9094, SL 9094: 35 mm width
• Monitioring of
- overtemperature
- broken wire detection in sensor circuit
- short circuit detection in sensor circuit
• 1 input for 1 to 6 PTC-resistors
• De-energized on trip
• LED-indicator for
- auxiliary supply
- state of contact
• Output with 2 changeover contacts
• As option with manual reset, internal reset button and external
remote reset X1/X2
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
Maximum functionality for your application
DOLD offers custom solutions for the monitoring of electrical variables such as current, voltage, power, resistance, et cetera. The measuring relays report error conditions and thus offer increased protection even for complex systems as well a ensure an optimal production process. LEDs on the front of the device provide you with optimal information about the current condition. We can provide you with both mono-functional and multifunctional relays with which you can realise your solutions with minimal costs or maximum flexibility and functionality.






Ответ от производителя может занять до 5 дней и более.