• Programmable: fleeting on make, fleeting on break,
fleeting on make and brake
• Fleeting time 0.3 ... 0.6 s fixed
• Repeat accuracy < ± 5 %
• LED indication for supply and contact position
• 2-wire-proximity sensor control
• Available with 1 or 2 changeover contacts
• Width 22.5 mm
• Fleeting make
• Fleeting time up to 300 s or on request
• Repeat accuracy < ± 0,5 %
• Setting on absolute scale
• Available as 2-voltage version
• LED displays for availability and contact position
• 2 fleeting make or
1 fleeting make and 1 non-delayed changeover contact
• Also available with instantaneous contact
• Also available with CSA approval
• Width 22.5 mm
• Optionally safe separation according to IEC/EN 61 140,
IEC/EN 60 947-1, 6 kV/2
- between coil and contacts
- between the two contacts
• As option with reduced power consumption
• Optionally for switching of low loads
• 1 or 2 changeover contacts
• for AC/DC 12 ... 240 V
• For 2-wire proximity sensors
• LED indicator
• Width 22.5 mm
• Easier mounting
• Preassembled modules available in the requested direction
• Easier mounting
• Height adjustment when using functional units with the mounting plate
DIN rail mounting or screw-type mounting
• Mounting on the top-hat rail may be done horizontally or vertically
DIN rail mounting or screw-type mounting
• Mounting on the top-hat rail may be done horizontally or vertically
DIN rail mounting or screw-type mounting
• Mounting on the top-hat rail may be done horizontally or vertically
connected, security module (e. g. BG 5925/920 or LG 5925/920)
• According to IEC/EN 60 204-1, EN 1088
• 2 channel system
• Standard switching distance: San ≤ 5.5 mm
Sab ≥ 13 mm
• 2 NO semiconductor outputs providing diversity and redundancy
• Magnetic coded, safe against manipulation
• Open end connection wires
• M8 or M12 connector as option
• Long service life
• Easy to mount
• Resistant against vibration
• Not sensitive to external magnetic fields
• Protection class IP 67
• LED indicator
connected, security module (e. g. BG 5925/920 or LG 5925/920)
• According to IEC/EN 60 204-1
• Standard switching distance: San ≤ 7 mm
Sab ≥ 18 mm
• Max. number of switches in series:
- 6 NE 5021 on control unit BG 5925/920 or LG 5925/920
- 10 NE 5021 on multifunctional safety timer UG 6960 and UG 6961
- 10 NE 5021 on multifunctional safety module UG 6980
- 20 NE 5021 on multifunctional safety module UG 6970
- 20 NE 5021 on multifunction module BH 5910
• 2 NO contacts or 2 NO contacts / 1 NC contact
• Contacts protected against welding
• Very long service life
• Easy to mount and service
• Manipulation is difficult due to coded sensor
• Protection class IP 67
NI 5061.43: Emergency stop with 2 NC contacts (forced opening) +
1 NO contact
• M12-connection
NI 5061.06: 4-poles
NI 5061.43: 8-poles
• Twist release left or right
• Foolproof acc. to EN ISO 13850
• A ccording to EN 60947-5-1, EN 60947-5-5
• Can be switched off before the time expires
• Operating times between 0.5 ... 60 min., as required
• IK 8813 with permanent light switch and LED indicator for contact
position
• IK 8813 for installation in rows, width 17.5 mm
• OA 8823 for installation in flush-mounted boxes
• Reswitching possible
• Operating times between 0.5 ... 60 min., as required
• IK 8814 with permanent light switch and LED indicator for contact
position
• IK 8814 for installation in rows, width 17.5 mm
OA 8824 for installation in flush-mounted boxes
• With 2 delay times
- 0.3 ... 5 min. if the pushbutton is pressed briefly (< 1 s)
- 1.2 ... 20 min. if the pushbutton is pressed for a long time (> 1 s)
i.e. the delay time is four times as long
• Operating time adjustment with a screwdriver
• Reswitching possible
• IK 8825 with permanent light switch
• Permanent light as long as the pushbutton is pressed
• IK 8825 for installation on a top hat rail
• OA 8825 for installation in flush-mounted boxes
• Width IK 8825 17.5 mm
• Detection of incorrect phase sequence
• No separately auxiliary voltage necessary
• Nominal voltage range 3 AC 380 ... 690 V
• Suitable for operation with inverters (f = 40 ... 80 Hz)
• Relay output:
- IL/SL 9059: 1 changeover contact
- OA 9059: 1 NC contact
• Extended temperature range
• Devices available in 3 enclosure versions:
I L 9059: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
SL 9059: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• OA 9059: sealed modul with stranded wire connection
suitable for mounting in terminal box
• Width
- IL/SL 9059: 35 mm
- OA 9059: 62 mm
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5.5 mm
Double and reinforced insulation with pollution degree 2
Overvoltage category: III
• High voltage resistance ≥ 4 kV
• High mechanical service life
• High temperature range
at OA 5601 and OA 5602: -40 ... +85°C
at OA 5603: -40 ... +75°C
• High continiuous thermal current Ith = 10 A
• High voltage range 0.7 ... 1.6 UN
• As option wash proof RT III
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5.5 mm
Double and reinforced insulation with pollution degree 2
Overvoltage category: III
• High voltage resistance ≥ 4 kV
• High mechanical service life
• High temperature range
at OA 5601 and OA 5602: -40 ... +85°C
at OA 5603: -40 ... +75°C
• High continiuous thermal current Ith = 10 A
• High voltage range 0.7 ... 1.6 UN
• As option wash proof RT III