• According to IEC/EN 60 255
• To monitor for battery systems (emergency power supply)
• Measuring rang DC 0.12 ... 1.2 V or 0.2 ... 2 V
• Without separately auxiliary voltage
• High overload possible
• With time delay 10 s
• LED indicators for operation and contact position
• Width: 45 mm
BA 9054/332
as BA 9054/331 but with
• battery voltages up to 500 V
• separately auxiliary voltage
• According to IEC/EN 60 255
• To monitor for battery systems (emergency power supply)
• Measuring rang DC 0.12 ... 1.2 V or 0.2 ... 2 V
• Without separately auxiliary voltage
• High overload possible
• With time delay 10 s
• LED indicators for operation and contact position
• Width: 45 mm
BA 9054/332
as BA 9054/331 but with
• battery voltages up to 500 V
• separately auxiliary voltage
• Detection of
- underspeed
- overspeed
- standstill
• Adjustable response value
• BA 9055 with adjustable start-up delay
• AA 9050 with adjustable hysteresis
• Width 45 mm
• Detection of underload (cos ϕ)
• Current ranges up to 10 A, for higher values a CT must be used
• Adjustable response value
• Programmable functions:
- alarm when I = 0
- automatic or manual reset
- closed or open circuit operation
• Manual remote reset
• Adjustable operate delay
• Independent of phase sequence
• Also for 400 Hz systems
• Optionally for motors with frequency converters (10 ... 100 Hz)
(see notes)
• Width 45 mm
• 2 PT 100 inputs with separate outputs or alternatively
common output
• Optionally 1 PT 100 input with 2 separate outputs for
2 different response values
• Separate adjustable response and release values for each input
• Optionally with fixed response and release values
• Broken wire detection in sensor circuit
• Closed circuit operation
• 2 wire connection
• Width 45 mm
and part 303
• 1 input for PTC-resistors or bimetal contacts
• Broken wire detection in sensor circuit
• Optionally with no voltage reclosing interlock
• Closed circuit operation
• 1 or 2 changeover contacts
• Width 45 mm
• Choice of direction in 4 increments of 90°
• Simple assembly by plugging and turning
• Choice of direction in 4 increments of 90°
• Simple assembly by plugging and turning
• This accessories are also available in stainless steel
• Time delay between 0.05 s ... 10 h
• Repeat accuracy ≤ 0.5 % + 10 ms
• Dual voltage supply
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled
(isolated), DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• Fleeting action
• Repeat time adjustable to 100 s
• Repeat accuracy ≤ 0.5 % + 10 ms
• Dual voltage supply
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• Fréquence clignotante réglable, durée d‘impulsion jusqu‘à 100 s
• Début par impulsion
• Précision de répétition ≤ 0,5 % + 10 ms
• Exécution bitension
• DEL pour visualisation de la position des contacts
• 1 contact INV
• Connectique également 2 x 1,5 mm2 multibrins avec
embout et collerette plastique DIN 46 228-1/-2/-3/-4 ou
2 x 2,5 mm2 multibrins avec embout DIN 46 228-1/-2/-3
• Largeur utile 22,5 mm
• Time ranges between 0.05 s and 10 h
• Settable release delay
• With auxiliary voltage
• Wide voltage range AC 110 ... 240 V
• Control input operated with nominal voltage,
No voltage free contact necessary
• LED indicator for status of contact
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• 8 switching ranges from 0.05 s ... 16 h
• Infinite variable delay on every range 1 : 10
• Dual-voltage design as standard (e.g. AC 230 V + AC/DC 24 V)
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• 8 functions selectable by rotational switch:
AV - operate delay
EW - fleeting on make
IE - delayed pulse function
BE - flasher start with impulse
RV - release delay
IF - pulse forming
AW - fleeting on break
AV/RV - operate / release delay
• With 10 time ranges up to 300 h selectable by rotational switch
• Time addition via control input B1 for the functions AV, EW, IE, BE
• Time ranges up to 300 h
• AC/DC 24 ... 240 V
• 1 changeover contact
• LED indicators for voltage supply and contact position,
flashing function during elapse of time
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• Time ranges up to 100 s
• Repeat accuracy ≤ 0.5 % + 10 ms
• 2-voltage design
• LED indicators for contact position
• 1 NO contact fleeting make
1 NO contact operate delayed
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• With 10 time ranges from 0.05 s ... 300 h
• Impulse and break time separately adjustable
• Selectable start with impulse or break
• AC/DC 24 ... 240 V
• Control input for interruption of the time elapse
• LED indication for voltage supply and contact position
• Flashing function during elapse of time
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• 1 changeover contact
• Delay of 0.05 ... 300 s
• Wide voltage range
• Repeat accuracy ≤ 1 %
• Without auxiliary voltage
• LED indicator for operation
• Devices available in 3 enclosure versions:
IK 7819: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7819,
BC 7938N: depth 98 mm, with terminals at the top for
cabinets with mouning plate and cable duct
• IK/SK 7819: width 17.5 mm
BC 7938N: width 22.5 mm
• 8 settable time ranges between 0.05 s and 10 h
• Settable release delay
• With auxiliary voltage
• Wide voltage range AC 110 ... 240 V
• Control input operated with nominal voltage,
No voltage free contact necessary
• LED indicator for status of contact
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• Fast detection of undervoltage and phase failure in AC voltage
systems
• Detects voltage drops (reaction time ≤ 20 ms)
• Response value 0.8 or 0.7 UN selectable by wire link
• Without auxiliary supply
• De-energized on trip
• LED indicator for contact position
• Adjustable operate delay after return of voltage
• As option adjustable fleeting on make pulse after return of voltage
(variant BC 9190N.11/001)
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3/-4
• Width 22.5 mm
• Setting range 200 kΩ to 2 MΩ
• LED indicators
• Output: 1 NO contact
• De-energized on trip
• Test button for function check
• Reset button
• Input for voltage detection
• Manual reset available by bridge
• Width 45 mm