Поставляем DOLD под заказ
Все товары DOLD
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut,
autostart
- 8 E-STOP, single-channel, manual start
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
- 5 E-STOP, single-channel, + 1 E-STOP, 2-channel +
1 signal input, manual start
- As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected.
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs per function module for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
- Performance Level (PL) d and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Input module with enabling inputs
• for connection of 2 channel
- safety gates
- e-stop buttons
- light curtain (LC) Type 4
- change over switch
- enabling swtich
• Function combination and behaviour of enabling inputs selectable on
rotary switches
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5915) or 45 mm (BH 5915)
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• According to EN 50156-1 for furnaces
• Single channel or two-channel operation
• Output: max. 4 NO contacts
• AC 230 V model with galvanic separation
• LED indicator for channel 1 / 2 and state of operation
• Short circuit detection between terminal Y1 and common
• BG 5924 with:
- Removable terminal strips
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• BG 5924: width 22.5 mm
• IP 5924: width 70 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 3 NO contacts, see contacts
• Single and 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• With or without cross fault monitoring in the E-stop loop, switch S1
• LED indicator for channel 1 and 2 and Power
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 3 NO contacts, see contacts
• Single and 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• For light curtains with symmetric or asymmetric outputs,
selection via S1
• Option: fast auto start
• LED indicator for channel 1 and 2 an power
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Safety-mat switch gear with manual or automatic restart
• can also be used for safety edges
• Output: max. 3 NO contacts
• Line fault detection on On-button
• Manual restart or automatic restart when connecting the supply
voltage, switch S2
• LED indicator for state of operation
• Indicator for status of switching element
• LED indicator for channel 1 and 2
• Removable terminal strips
• Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2,5 mm2 stranded ferruled DIN 46 228-1/-2/-3/-4
• Width 22,5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• to connect:
- magnetic switch NE 5020
- magnetic switch NE 5021
• Output: max. 3 NO contacts, see contacts
• 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• Cross fault monitoring
• LED indicator for state of operation
• LED indicator for channel 1 and 2
• Optionally with fast Auto start
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
when connected to a suitable safety module
• Redundant and forcibly guided contacts
• Output: max. 5 NO contacts or 4 NO contacts / 1 NC contact
• 1- or 2-channel connection
• LED indication for operation
• Removeable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- Safety Level Type III-C according to EN 574
- the safety regulations for two-hand controls on power-operated
presses in metalworking ZH 1-456
• Inputs for 2 push buttons with 1 NC and 1 NO contact
• Output: 2 NO contacts, 1 NC contact or
3 NO contacts, 1 NC contact
• Feedback circuit Y1 - Y2 to monitor external contactors used
for reinforcement of contacts
• Overvoltage and short circuit protection
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• BG 5933: width 22.5 mm
BH 5933: width 45 mm
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
- Category 2 nach EN 954-1
• Variants /_ _2 to /_ _3
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
- Category 3 to EN 954-1
• Adjustable time delay
• Long time stability by digital timing circuit
• With auxiliary voltage
• 1 timing circuit
• BH 7925 in dual voltage version
• BH 7925 optionally for AC 230 V
• Output: 1 NC contact, 1 NO contact, forcibly guided or
1 NC contact, 3 NO contacts, forcibly guided
• Indication of state of operation
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Optionally with 2 timing circuits
• Optionally fixed time delay
• Optionally without auxiliary voltage on BH 7925
• Optionally for switching small loads
• BG 7925: width 22.5 mm
BH 7925: width 45 mm
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Redundant and forcibly guided contacts
• 1 timing circuit
• Fixed time delay 1, 2 or 3 sec
• Without auxiliary supply
• Output: 5 NO contacts or 4 NO contacts / 1 NC contact,
1 NC contact for feed back circuit
• Indicator LED for operation
• Removable terminal strips
• Wiring diameter: also 2 x 1.5 mm2 stranded ferruled with sleeve
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled
DIN 46 228-1/-2/-3
• Width 22.5 mm
modules, e.g. input and error states, start button and safety output
assignments, to a control system or bus-capable display
• Electrical isolation
• Automatic recognition of transmission speed
• LED indicators for operating voltage and status
• Width of 45 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Category 4 to EN 954-1
• To connect max.:
- 3 light curtains 2-channel or
- 2 light curtains 2-channel and 2 muting sensors 1-channel or
- 1 light curtain 2-channel and 4 muting sensors 1-channel or
- 2 light curtains 2-channel and key switch for stepping operation
- additionally: Start button and machine contact with line fault detection
• Broken wire detection on light curtain input
• Outputs:
- 3 NO or 2 NO and 1 NC
- 2 Semiconductor outputs, protected against short circuit and overload
• Multifunction device, different functions selectable by rotational
switches:
- protective operation e.g. light curtains
- protective operation with muting, e.g. conveyors
* signal sequence of muting sensors can be selected
* override function via start button
- Stepping operation e.g. on presses
* optionally with key switch
* 1, 2 or 3 steps possible
* setting of number of step possible via selector switch
• Suitable to connect light curtains of type 4 or selftesting light curtains
type 2 according to IEC/EN 61 496-1, crossfault monitoring in the light
curtain
• With under- and overvoltage detection and indication
• Reaction time: max. 30 ms
• LED indication for RUN and Channel 1,2
• Width 45 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Category 4 to EN 954-1
• E-stop with latching function
• Automatic start when voltage returns after phase failure
when no E-Stop was operated before phase failure.
• Reset after E-stop with push button
• Output max. 3 NO contacts, see contacts
• B_ 5903._ _ /00000: 1 E-stop loop 2-channel operated
• B_ 5903._ _ /00020: 2 E-stop loops single channel operated
• Cross fault monitoring
• Feedback loop for external contact reinforcement
• Short circuit and broken wire detection on all inputs
• LED indication for channel 1 and 2 and for diagnostics
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• BH 5903: width 45 mm
BL 5903: width 90 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Category 4 to EN 954-1
• Way of valve monitoring adjustable (2 NC, 2NO, 1 changeover
contact)
• Reset button to acknowledge after fault detection
• Available with continuous monitoring of the valve or just with one
check per cycle
• Contact reinforcement by external contactors possible
• Short circuit and cross fault detection
• Broken wire detection
• Outputs: 2 NO contacts
• 2 semiconductor outputs with short circuit, overload and
temperature protection to monitor the status
• Under and overvoltage detection
• Reaction time: max. 28 ms
• LED operation indicators (run 1, run 2 )
• Width 45 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Category 4 to EN 954-1
• Functions selectable via rotational switches to connect max.:
- 8 E-stop circuits, single channel or
- 4 E-stop circuits, 2-channel or
- 4 light curtains or
- 2 light curtains and 1 E-stop circuit or
- 4 safety gates or
- 2 safety gates and 1 E-stop circuit or
- 4 pairs of 2-hand-buttons or Typ III A according to DIN EN 547 or
- 2 pairs of 2-hand-buttons Typ III C according to DIN EN 547
and 1 E-stop circuit
• In addition selectable:
- auto or manual reset (simulation input for gate monitor)
- continuously monitored feedback circuit to monitor external
contactors
• Cross fault detection
• Short circuit and broken wire detection
• Outputs:
- 3 NO or 2 NO and 1 NC contacts
- 2 semiconductor outputs short circuit proof and overload
protected
• Under- and overvoltage detection and signalling
• LED indication for operation (RUN), channel 1/2
• 45 mm width
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact
• Parallel connection of several SAFEMASTER M-systems possible
• The functions are selected via rotary switch
- 1 Emergency stop circuit, 2-channel
- 2 Emergency stop circuits, single-channel
- 1 Emergency stop circuit, 2-channel + 1 stop single channel
• Auto or manual start
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Overvoltage and undervoltage monitoring function with error indication
• Permanently monitored feedback loop to connect external contactors
• Broken wire and short circuit monitoring function with error indication
• Width: 45 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact
• Parallel connection of several SAFEMASTER M-systems possible
• The functions are selected via rotary switch
- 1 Emergency stop circuit, 2-channel
- 2 Emergency stop circuits, single-channel
- 1 Emergency stop circuit, 2-channel + 1 stop single channel
• Auto or manual start
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Overvoltage and undervoltage monitoring function with error indication
• Permanently monitored feedback loop to connect external contactors
• Broken wire and short circuit monitoring function with error indication
• Width: 45 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain (LC type 4)
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width
BG 5913.08/_0__: 22.5 mm
BH 5913.08/_0__: 45 mm
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut,
autostart
- 8 E-STOP, single-channel, manual start
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
- 5 E-STOP, single-channel, + 1 E-STOP, 2-channel +
1 signal input, manual start
- As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected.
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs per function module for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
Запросите коммерческое предложение























Ответ от производителя может занять до 5 дней и более.