Поставляем DOLD под заказ
Все товары DOLD
• Detection of standstill of rotating machine parts and cyclic pulses
• Detection of blocking or missing pulses
• Monitoring time adjustable between 0.1 ... 20 s (others on request)
• Energized or de-energized on trip
• For input frequency up to 5 kHz( 300000 ipm)
• Universal input, suitable for a variety of sensors
(PNP,NPN,2-wire, contact, voltage)
• Input also suitable for SKF sensor bearings
• As option for Namur sensors
• On request with manual reset
• IK 9144 and SK 9144: compact version for DC 24V auxiliary supply
• IL 9144 and SL 9144: for auxiliary supply up to AC 400V with
galvanic separation to sensor input
• LED indicators for auxiliary supply, sensor pulses and contact
position
• 1 changeover contact (2 changeover on request)
• Devices available in 2 enclosure versions:
IK/IL 9144: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK/SL 9144: depth 98 mm, with terminals at the top for
cabinets with mounting plate and cable duct
• IK 9144, SK 9144: width 17.5 mm
• IL 9144, SL 9144: width 35 mm
• Indication of phase failure in 3-phase systems
• Single phase connection possible
• Independent of phase sequence
• LED indicator for each phase
• Devices available in 2 enclosure versions:
IK 9168: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9168: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Detection of phase failure in 3-phase systems
• Single phase connection possible
• Closed circuit operation
• Independent of phase sequence
• LED indicator for each phase
• Output 1 changeover contact
• Devices available in 2 enclosure versions:
- I- and R-versions, e.g. IK 9169 with depth 61 mm or RK 9169
with depth 71 mm with terminls at the bottom for installation
systems and industrial distribution systems according to DIN 43880
- S-version, e.g. SK 9169: depth 100 mm, with terminals at
the top for cabinets with mounting plate and cable duct
• Width 17.5 mm
• Monitoring of overvoltage in 3-phase systems
• Also for single phase
• Without auxiliary supply
• Settable response value
• N.C. circuit operation (optionally N.O. circuit operation)
• Optionally with or without N
• Optionally with delay t1 on trip
• Optionally with delay t2 on reset
• LED indicator for state of output relay
• Indepenent of phase sequence
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9170: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9170: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Monitoring of undervoltage in 3-phase system
• Also for single phase
• Without auxiliary supply
• Optionally for 3p3w systems
• LED indicator for state of output relay
• Independent of phase sequence
• 1 or 2 changeover contacts
• Optionally fixed or settable response value
• As option with phase sequence detection
• Optionally with or without N
• Optionally with off-delay t1
• Opionally with on delay t2
• Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width:
IK 9171, SK 9171: 17.5 mm
IL 9171, SL 9171: 35 mm
• Monitoring of overvoltage
• Without auxiliary supply
• Settable response value
• De-energized on trip
• LED indicator for state of output relay
• 1 changeover contact
• As option energized on trip
• As option with delay t1 on trip
• As option with delay t2 on reset
• Devices available in 2 enclosure versions:
IK 9171: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9171: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Monitoring of undervoltage
• Without auxiliary supply
• Optionally fixed or settable response value
• N.C. circuit operation
• Optionally with off-delay t1
• Optionally with on-delay t2
• LED indicator for state of output relay
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9173: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9173: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Indication of phase sequence in 3-phase systems
• Without auxiliary supply
• LED indicator for phase sequence
• Devices available in 2 enclosure versions:
IK 9178: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9178: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Detection of phase sequence in 3-phase systems
• Without auxiliary voltage
• Closed circuit operation
• LED indicator for phase sequence
• Output 1 changeover contact
• Devices available in 2 enclosure versions:
- I- and R-model, e.g. IK 9169 with depth 61 mm or RK 9169
withdepth 71 mm with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
- S-model, e.g. SK 9169 depth 100 mm, with terminals at
the top for cabinets with mounting plate and cable duct
• Width 17.5 mm
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• As option energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
-- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
-- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Fixed hysteresis approx. 4 %
• Adjustable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9272: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9272: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Setting value adjustable from 0.1 ... 1 IN
• Fixed hysteresis approx. 4 %
• Settable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage and contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9273: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9273: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 1 changeover contact
• As option connection of a remote potentiometer 10 kΩ
• As option with time interruption / time adding input
• LED indicators for operation, contact position and time delay
• Devices available in 2 enclosure versions:
I K 9906: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9906: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct.
• 17.5 mm width
• 8 time ranges from 0.05 s to 300 h selectable via rotational switch
• With auxiliary supply
• Voltage range AC/DC 12 ... 240 V for auxiliary supply
and control input
• No voltfree control contact necessary
• Adjustment aid for quick setting of long time values
• LED indicators for operation, contact position and time delay
• 1 changeover contact
• As option connnection of remote potentiometer 10 kΩ
• Devices available in 2 enclosure versions:
IK 9962: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9962: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct
• 17.5 mm width
• Setting range 0.5 ... 10 min.
• For 3-wire circuit N on push button
• Can be not retriggered
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm
• 2 independent relays in once enclosure
• 2 measuring ranges from 0.5 to 5 A
• Adjustable response values
• Fixed hysteresis
• Adjustable switching delay
• Closed circuit operation
• LED indicators
• with auyiliary voltage
• galvanic separation between Auxiliary Circuit and Measuring Circuit
• 2 models available:
IL 5201: 63 mm deep with terminals near to the bottom to be
mounted in consumer units or industrial distribution
systems according to DIN 43 880
SL 5201: 100 mm deep with terminals near to the top to be mounted
in cabinets with mounting plate and cable ducts
• Width: 35 mm
• Operation as master
- Operation as slave
- Transfer rate up to 1 Mb/s
- Interface according to DS301 version 3.0
• IN 5504 locally extendable with digital and analoge in- / output
modules
• 2 digital inputs for DC 24 V
• 2 relay outputs
• LED indicators
• Standard programming software CODESYS® under Windows
according to IEC/EN 61131-3:
- Instruction set
- Ladder diagram
- Function block diagram
- Sequential function chart
- Structured text (similar to Pascal)
• 128 KB Flash memory for user program
• 128 KB RAM for user data
• 16 KB battery buffered RAM for no-voltage safe data
• Battery buffered real time clock
• Monitoring contact for RUN status of the PLC
• IL 5504: 35 mm width
IN 5504: 52.5 mm width
• Space saving with 2 analogue outputs at 35 mm width
required space not more then for 2 standard line circuit breakers
• 2 analogue outputs, optionally with each 2 x 0 ... 10 V, 2 x 0 ... 20 mA,
2 x -10 V ... +10V oder 2 x 4 ... 20 mA
• 12 bit resolution allows accuracy of < ± 0.1 %
• Galvanic separation between logic, output and bus guarantees
high interference immunity
• No external voltage source necessary for output signal
• Can be used in all CANopen networks due to high data transmission
rate up to 1Mbit/s
• Free configuration software CoDeSys
• According to IEC/EN 61 131-2
• CANopen interface according to DS301 version 3.0, DS401
• LED indicators for supply voltage and Bus status
• CANopen interface according to DS301 version 3.0, DS401
• 2 analogue inputs with each 2 x 0 ... 10 V, 2 x 0 ... 20 mA
or 2 x Pt 100 (- 50 ... 300°C)
• Galvanic separation between inputs, bus and auxiliary supply
• LED indicators for supply voltage and Bus status
• 35 mm width
Запросите коммерческое предложение