- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• For light curtains with symmetric or asymmetric outputs
adjustment with switch S1
• Output: max. 4 NO contacts, see contacts
• Single and 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• LED indicator for state of operation
• LED indicator for channel 1 and 2 and power
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• to connect:
- safety switch NE 5020
- safety switch NE 5021
• Output: max. 4 NO contacts, see contacts
• 1- or 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• with or without cross fault monitoring switch S1
• LED indicator for state of operation
• LED indicator for channel 1 and 2
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Output: 2 NO instantaneous contacts and 1 release delay contact
• 1- or 2-channel connection
• Line fault detection at the ON pushbuttons at connection on
terminals S33-S34
• Manual restart with button on S33-S34 or automatic restart with
bridge between S13-S34
• With or without cross fault monitoring in the E-stop loop
• Indication for released time circuit
• LED indication for supply, channel 1/2 and release delayed contacts
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
when connected to a suitable safety module
• Control from semiconductor safety outputs (light curtains,
e-stop, etc.) is also possible
• Redundant and forcibly guided contacts
• Output: max. 5 NO contacts or 4 NO contacts / 1 NC contact
• 1-channel or 2-channel connection
• LED indication for operation
• Removeable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- Safety level Type III-C to EN 574
• Inputs for 2 push buttons with 1 NC and 1 NO contact
• Output: 3 NO contacts, 1 NC contact
• Feedback circuit Y1 - Y2 to monitor external contactors used
for reinforcement of contacts
• Overvoltage and short circuit protection
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
-- Performance Level (PL) e and category 3 to EN ISO 13849-1
-- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
-- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• According to IEC/EN 60 204-1
• Output: 2 redundant safety outputs
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• Indication for operating condition
• LED indicator for channel 1 and 2
• As option with pluggable terminal blocks for easy exchange
of devices
-- with screw terminals
-- or with cage clamp terminals
• Width: 22.5 mm
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Adjustable time delay
• As option fixed time delay
• High long life stability due to digital time base
• Adjustable with or without cross fault detection
• Output: 3 NO contacts + 1 NC contact + 1 forcibly guided
feedback contact
or 4 NO contacts + 1 forcibly guided feedback contact
• LED indicator for channel 1, 2 and operation voltage
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Adjustable time delay
• As option fixed time delay
• High long life stability due to digital time base
• Adjustable with or without cross fault detection
• Output: 3 NO contacts + 1 NC contact + 1 forcibly guided
feedback contact
or 4 NO contacts + 1 1 forcibly guided feedback contact
• LED indicator for channel 1, 2 and operation voltage
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508, IEC/EN 61511 and EN 61800-5-2
• Safe standstill detection on 3- and single-phase motors
• No external sensors necessary
• Independent of direction
• Broken wire detection
• Forcibly guided safety contacts:
3 NO contacts, 1 NC contact for AC 250 V
• 2 semiconductor monitoring outputs
• 1 monitoring output (NO contact)
• Adjustable voltage setting
• Adjustable standstill time delay
• LED indicators for standstill, event of line breakage and
operation voltage
• Suitable for operation with inverters
• Width 45 mm
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Width: 90 mm
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g.
for mains couplings
• 1 changeover contact each for prewarning and alarm
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Alarm storage selectable
• External test and reset pushbutton can be connected
• Width 90 mm
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g.
for mains couplings
• 1 changeover contact each for prewarning and alarm
• 3. output relay for signalling wire break and device faults
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Alarm storage selectable
• External test and reset pushbutton can be connected
• Width: 90 mm
• Detection of symmetric and asymmetric insulation faults
• 1 changeover contact each for prewarning and alarm
• 3. output relay for signalling wire break and device faults
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display " measuring circuits active"
• Display "Master" or "Slave"
• Automatic and manual device self-test
• Alarm storage selectable
• External test and reset pushbutton can be connected
• With watchdog timer to monitor the trigger signal
• Width: 90 mm
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
• Monitors also disconnected voltage systems
• Adjustable tripping value RALof 5 ... 100 kΩ
• De-energized on trip
• Auxiliary voltage, measuring circuit and output contacts are galvanically separated
• Manual and auto reset
• With test and reset button
• Connections for external test and reset buttons possible
• LED indicators for operation and alarm
• 2 changeover contacts
• MK 5880N/200 with additional prewarning
- adjustable prewarning value 10 kΩ ... 5 MΩ
- 1 output relay for alarm and 1 for pre-warning
• MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• MK 5880N: 22.5 mm width
MH 5880: 45 mm width
• Detection of high or low-rpm / stand still (adjustable function)
• Large setting range 1 ... 120.000 IPM or
0.15 ... 20.000 Hz (10 ranges each)
• As option with input for NAMUR-sensors with sensor and
wire protection against interruption and short circuit
• Adjustable hysteresis 0.5 ... 50 %
• Adjustable start up time delay 0 ... 50 s, control with external contact
• Adjustable monitoring time for missing input signal at function
overfrequency; additional using as standstill level
• Programmable via termminals:
- Alarm delay of 0 ... 100 s
- with manual reset or auto reset
• LED-indication for auxiliary voltage, measuring input and output relay;
additional LED for indication of wire- / sensor failure at NAMUR-input
• Auxiliary voltages AC 230 V and DC 24 V in one unit
• 2 changeover contacts, closed circuit operation
• Open circuit operation on request
• As option with analogue output, proportionally to speed
• Device available with 2 response values and seperately controlled
output relays for under- and overfrequency see MK 9055N/5_ _
• MH 9055 with wide input range for auxiliary voltage
(AC/DC 24 ... 60 V or AC/DC 110 ... 230 V)
• 2 possible compact designs
MK 9055N: Width 22,5 mm
MH 9055: Width 45 mm
• Start up delay, on delay
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9064N: 1 changeover contact
MH 9064: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• With RS485 (on request)
• Width MK 9064N: 22.5 mm
• Width MH 9064: 45.0 mm
• Monitoring of 50 - and 60 Hz-current supply on
over- and underfrequency
• Monitoring of local generator sets and voltage supplies
• For precise frequency measuring with fast response time
• High disturbance immunity
• Separately adjustable trip points and separate outputs for overand
underfrequency (1 or 2 c/o each)
• MK 9143N / MH 9143:
- Trip points adjustable precisely and reproducible on 10 step
rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to
50 or 60 Hz
- Nominal frequency 50 or 60 Hz selectable
- Fixed hysteresis optimised for trip point
- Time delay for over and underfrequency each adjustable
from 0 to 20 s
- As option one common output for under and overfrequency
“Window”-mode (MK 9143N/400 / MH 9143/400)
• MH 9143.38/008: with galvanic separated analogue output (current/
voltage) and 11 step LED chain for the actual frequency
• MK 9143N/600 / MH 9143/600:
- Variable alarm value in the range of 45 to 65 Hz
- Hysteresis adjustable for under- and overfrequency separately
adjustable 0 …20%
- Common output for under and overfrequency “Window”-mode
can be selected
• Start up delay 0…30 s selectable
• Manual or auto reset selectable
• Output relay energized or de-energized on trip selectable for
overfrequency
• Output relay de-energized on trip for underfrequency
• Universal frequency measuring input for AC 40 … 550V
• Several options for auxiliary supply
• As option without aux. supply for voltage range AC 18 … 70 V or
70 … 275V
• LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
• 2 possible contact arrangements
MK 9143N and MK 9143N/600: 2 x 1 C/O contacts, width 22,5 mm
MH 9143 and MH 9143/600: 2 x 2 C/O contacts, width 45 mm
• Voltage monitoring (1- and 3-phase)
• Current monitoring
• Frequency monitoring
• Power factor cos phi
• Phase sequence, phase failure, asymmetry
• Effective-, reactive- and apparent power
• Start up delay, on delay
• Adjustable hysteresis 0.2 ... 50 % of response value
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9300N: 1 changeover contact
MH 9300: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• MH 9300: Width 45 mm
• Active power measuring
• Relay output
MK 9397N: 1 changeover contact
MH 9397: 1 changeover contact each for overload and prewarning
• On delay
• Closed circuit operation
• As option open circuit operation
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• MK 9397N: Width 22,5 mm
MH 9397: Width 45 mm